Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge 9990 : Field Action Bulletins


FAB Former ID Synopsis Last Modified Date
1231323.1 Relocation of the US HDS Spares Distribution Center for Storage 99xx field returns on or after October 21, 2010. 2010-10-11
1022191.1 277110 Logical Devices in ST9990 may block when the DKU Array Frame is running on only one redundant power supply and a sufficient quantity of DKS2D-K146FC HDDs are installed. 2010-08-05
1020441.1 258488 Must follow Battery Management Procedures to guarantee the integrity of ST9900 products. 2010-09-23
1019622.1 242466 Possible failure of multiple HDDs of certain type within the same Parity Group in ST9990V, ST9985V, ST9990 and ST9985. 2010-11-03
1019433.1 239625 Requirement for SE9900 Series Arrays Microcode level to be at Mandatory General Availability (MGA). 2011-05-12
1017445.1 228549 Essential Battery Management Procedures for Sun StorEdge 99x0 Products. 2010-08-27
1017434.1 228537 Changes to SE99XX activation and notification process for monitored systems. 2010-08-20
1017432.1 228535 Unauthorised Modifications to StorEdge 99x0 Service Processor (SVP) - Windows Operating System 2010-11-11
1017362.1 228427 Sun StorEdge 9990 Shared Memory Inconsistency Between Physically Installed and Logically Configured Can Lead to Data Access Disruption or Loss. 2010-08-23
1001324.1 201786 Effective July 13, 2006 - All Case Routing Information For Devices Using the SAMS3/ACCR SSRR HiTrack Applications For Automatic Case Creation And Routing Will Be Handled Via SunRoute. 2010-08-25
1001163.1 201557 New SE9990 DKU backplanes allow FSW-A placement on left side without need for right side FSW PCB. If run in unsupported configurations, disk unit frame will overheat. 2010-09-01
1001062.1 201389 SE9990 SVP - Windows XP SP2 - may cause SVP-DKC communication errors. 2010-11-10
1001035.1 201362 Sun StorEdge 99xx Arrays Might Encounter Data Integrity Issues After VMotion Guest Migrations. 2010-08-26
1001020.1 201346 ST99xx Hitachi Hard Drives (DKR2D, DKR2E and DKR2F) reliability improvement. 2010-10-21
1000969.1 201287 Accumulation of memory leak in HDLM for Windows may lead to an application error or system down. 2010-11-12
1000866.1 201147 TagmaStore USP/NSC High Capacity Cache and Shared Memory Installation. 2010-08-31
1000865.1 201146 Devices may become unavailable when attempting USP Non-Stop micro-program exchange on SE9985 or SE9990 systems 2010-08-31
1000857.1 201138 Intermix of HDD from different vendors in parity is supported with pre-requisite Microcode. 2010-08-31
1000853.1 201134 Enabling SE99x0 System Option Mode 186 prevents correct functioning of SCSI-2 Reservations 2010-08-31
1000844.1 201125 SE9990 Parity group addition will fail if the total number of currently installed HDDs + external strorage groups + new HDDs to be installed exceeds 2560. 2010-08-30
1000829.1 201109 Specified SE9990 components now require autodumps to be collected and returned on USB memory devices included with the spare PCBs(printed circuit boards). 2010-09-10
1000814.1 201093 Hitrack Version B.4 And Below Might Report Incorrect Data. 2010-09-10
1000729.1 200967 Incorrectly plugged SE9990 AC box cabling can lead to all devices becoming blocked. 2010-08-23
1000711.1 200929 SE9990 Battery Destage Mode should be set OFF until fixed microcode is released 2010-08-31
1000705.1 200923 Hitrack versions (prior to B.2) for the SE9990 and SE9985 arrays can exit unexpectedly and may not send SIM notifications. 2010-09-10
1000676.1 200888 PFIN - 101976 - International shipments - HDS Microcode CD's and Software Media 2010-08-25
1000485.1 200623 SE9990 Shared Memory or Cache Memory maintenance can cause Microprocessor blockades and lead to a total system outage. 2010-09-10
1000394.1 200517 Hi-Track version 8D Front application terminates unexpectedly when used with early versions of SE9990/USP Microcode. 2010-08-24
1000385.1 200507 Potential for cables to become trapped or mis-connected between DKC/DKU or DKU/DKU frames, during an SE9960, SE9980, or SE9990 unit installation, unit relocation or upgrade. 2010-08-23
1000384.1 200506 Host Group Option 16 cannot be set from Storage Navigator 2010-08-23
1000378.1 200500 Mode 80 disabled will cause "pairresync -restore" to perform a Quick Restore operation, which causes volume maps to swap and can lead to severe performance degradation. 2010-08-23
1000309.1 200426 A microcode bug exists in all V07+1 (50-07-51-00/00 and higher) microcode that in a limited number of configurations can cause all DKA MPs to blockade and recovery may be very disruptive. 2010-08-30
1000222.1 200297 Multiple issues with Graphtrack versions 7.0-7.2 2010-11-10
1000171.1 200220 ECC/LRC pinned data may occur if cache blockades on SE9990/SE9985 2010-09-02