|  Problem  Document 
     | 
     Former IBIS ID
     | 
      Synopsis 
     | 
  Last Modified Date
     | 
  
| 1017694.1 | 
228891 | 
Sun StorEdge[TM] A5000: luxadm insert error: can not initialize the loop | 
2011-03-03
 | 
| 1011944.1 | 
216350 | 
Sun StorEdge[TM] A5x00:Inquiry fails when issuing luxadm remove_device | 
2010-10-29
 | 
| 1010213.1 | 
214027 | 
WARNING: add_spec: No major number for sf | 
2010-09-13
 | 
| 1009316.1 | 
212895 | 
Stale or Obsolete Device Label for a Storage Device in Solaris[TM] | 
2009-12-04
 | 
| 1009229.1 | 
212769 | 
Offlined A5x00 disks return to online state after LIP | 
2010-09-14
 | 
| 1008668.1 | 
211884 | 
SCSI Transport errors and disks timeout failures on Sun StorEdge[TM] A5000 and T3, Sun Blade[TM] 1000 or Sun Enterprise[TM]3500 | 
2009-09-17
 | 
| 1008663.1 | 
211878 | 
What an AEN raid event with ASC=5D ASCQ=80 means, and what to do about it. | 
2009-09-14
 | 
| 1008606.1 | 
211756 | 
Cannot see Sun Storedge[TM] A5000 disks after install of Solaris[TM] 2.5.1 8/97 | 
2009-09-13
 | 
| 1008580.1 | 
211723 | 
Recovering from a failed FCAL boot disk | 
2011-03-03
 | 
| 1008569.1 | 
211708 | 
SunVTS[TM] failures with multiple SunStorEdge[TM] A5000 connected. | 
2009-09-23
 | 
| 1008074.1 | 
211117 | 
Sun StorEdge[TM] A5x00 Array: IO become unresponsive or hang on disks | 
2010-08-27
 | 
| 1007424.1 | 
210256 | 
How to Move a Sun Enterprise Volume Manager[TM] (SEVM) (or Veritas Volume Manager, VxVM) License From One Host to Another | 
2010-10-29
 | 
| 1005730.1 | 
207933 | 
Sun Enterprise Volume Manager[TM] 2.X does not show both paths in DMP as valid after replacing GBIC hardware. | 
2010-08-10
 | 
| 1005705.1 | 
207906 | 
Solaris[TM] 2.5.1 to 2.6 upgrade cannot  see new Sun StorEdge[TM] A5000 (Photon) disks | 
2010-09-14
 | 
| 1004620.1 | 
206406 | 
Sun StorEdge[TM] A5000:Symptom:luxadm Probe Returns Disk Drive Data Paths Instead of A5x00 Enclosure Information | 
2010-08-10
 | 
| 1003234.1 | 
204444 | 
Unable to remove a disk using `luxadm remove_device enclosure,dev` | 
2010-09-13
 | 
| 1003035.1 | 
204157 | 
Sun Enterprise Volume Manager[TM] (SEVM) 2.5/2.6: Running vxinstall on system with Sun StorEdge[TM] A5000 prompts for license | 
2009-09-28
 | 
| 1002168.1 | 
203073 | 
Mixing Fibre Channel HBA types on private-loop configurations can cause loop offline/timeouts. | 
2010-07-19
 | 
| 1001634.1 | 
202221 | 
luxadm probe fails to find attached Sun StorEdge[TM] A5000 | 
2009-09-30
 | 
| 1001617.1 | 
202203 | 
Disk Device Links in /dev/[r]dsk Do Not Get Created | 
2010-07-19
 | 
| 1001492.1 | 
202046 | 
"Lost Frame 0x14" errors with 18GB FC drives in Sun StorEdge[TM] A5X00's and Sun Enterprise[TM] 3500's | 
2009-09-27
 |