Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Enterprise[tm] 10000 Server - Full Components List

Backplanes
Communication
CPU Module
Disks
Ethernet
Fibre Channel
I/O Boards
    Memory
Power
SCSI
System Board
System Service Processor (SSP)
Exploded View
   
Table Legend
[F] = Field Replaceable Unit (FRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system

Backplanes
Option # Top Level
Part #
Manufacturing
Part #
Description
n/a n/a 501-4348 [F] Centerplane
n/a n/a 501-4346 [F] Centerplane Support Board
n/a n/a 565-1695 [F] Centerplane Power Module Repair Kit
Communication
Option # Top Level
Part #
Manufacturing
Part #
Description
X1071A 605-1636 370-3878 [F] HIPPI/P 1.1
X1080A 605-1649 370-4273 [F] Enterprise System Interface (ESI/P)
X1157A 605-1623 501-3028 [F] SunATM-155/MFiber PCI 4.0
X1012A [S] 605-1319 501-2603 [F] SunLink ISDN
X1070A [S] 605-1631 370-3878 [F] HIPPI/P 1.0
X1073A [S] 595-4344 370-2868 [F] SBus Cluster Interconnect Card (SCI)
X1142A [S] 605-1610 370-3142 [F] FDDI/S SAS 6.0
X1143A [S] 605-1609 370-3143 [F] FDDI/S DAS 6.0
X1144A [S] 605-1616 501-1932 [F] Token Ring Interface/SBus (TRI/S) 4.0
X1145A [S] 605-1612 501-1725 [F] High Speed Serial Interface/SBus (HSI/S) 3.0
X1146A [S] 595-5036 501-1931 [F] SBus Serial Parallel Controller (SPC/S) 3.0
X1147A [S] 605-1620 501-2794 [F] SunATM-155/MFiber 4.0
X1148A [S] 605-1621 501-2795 [F] SunATM-155/UTP 4.0
X1149A [S] 605-1622 501-2864 [F] SunATM-622/MFiber 4.0
X1158A [S] 605-1624 501-3027 [F] SunATM-155/UTP PCI 4.0
X1159A [S] 605-1625 501-3029 [F] SunATM-622/MFiber PCI 4.0
X2144A [S] 605-1645 501-1932 [F] Token Ring Interface/SBus (TRI/S) 5.0
CPU Module
Option # Top Level
Part #
Manufacturing
Part #
Description
X2530A [S] 595-4343 501-4178 [F] 250MHz UltraSPARC II
X2550A [S] 595-4410 501-4836 [F] 250MHz UltraSPARC II
X2560A [S] 596-2325 501-4363 [F] 333MHz UltraSPARC II
X2570A [S] 595-5065 501-5425 [F] 400MHz UltraSPARC II
(4MB Cache Sapphire-Black)
n/a [S] n/a 501-4995 [F] 400MHz UltraSPARC II
(4MB Cache Sapphire-Black)
X2580A [S] 596-2567 501-5661 [F] 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
501-5762 [F] 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
2580A [S]
(before April 2001)
596-2556 501-5814 [F] 400MHz UltraSPARC II
(8MB Cache Blaze)
IBM Sombra Mirrored Data SRAM
IBM Mirrored Tag SRAM
501-5815 [F] 400MHz UltraSPARC II
(8MB Cache Blaze)
Sony Espejo Mirrored Data SRAM
Sony Mirrored Tag SRAM
501-6009 [F] 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
IBM Sombra Mirrored Data SRAM
IBM Mirrored Tag SRAM
501-5838 [F] 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
IBM Sombra Mirrored Data SRAM
501-6008 [F] 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
IBM Sombra Mirrored Data SRAM
2580A [S]
(after April 2001)
596-2556 501-6619 [F] 400MHz UltraSPARC II
(8MB Cache Blaze)
IBM Sombra Mirrored Data SRAM
IBM Mirrored Tag SRAM
501-6624 [F] 400MHz UltraSPARC II
(8MB Cache Blaze)
Sony Espejo Mirrored Data SRAM
Sony Mirrored Tag SRAM
2590A [S] 596-3110 501-6620 [F] 466MHz UltraSPARC II
(8MB Cache Blaze)
IBM Sombra Mirrored SRAM
IBM Mirrored Tag SRAM
501-6623 [F] 466MHz UltraSPARC II
(8MB Cache Blaze)
Sony Espejo Mirrored SRAM
Sony Mirrored Tag SRAM
n/a [S] n/a 501-5798 [F] 466MHz UltraSPARC II
(8MB Cache Blaze)
Sony Espejo Mirrored SRAM
Sony Mirrored Tag SRAM
501-5816 [F] 466MHz UltraSPARC II
(8MB Cache Blaze)
IBM Sombra Mirrored SRAM
IBM Mirrored Tag SRAM
Disks
Option # Top Level
Part #
Description Assembly # Manufacturing
Part #
SG-ARY154A-72R4 [S] 596-2984 StorEdge D1000 12-Slot Rackmount
72GB (4 × 18.2GB) 10000 RPM
540-4178 [F]

A1000/D1000 FRU
w/ 1" Bracket 540-3024
w/ Plate 340-4288 or 340-6640
or 340-5928 or 340-7269
390-0002 [F]
390-0006
390-0038 [F]
390-0043
390-0048
390-0066
390-0085 [F]
SG-ARY173A-145R4 [S] 596-2985 StorEdge D1000 12-Slot Rackmount
145GB (4 × 36.4GB) 10000 RPM
540-4520 [F]

A1000/D1000 FRU
w/ 1" Bracket 540-3024
w/ Plate 340-4288 or 340-6640
or 340-5928 or 340-7269
390-0050 [F]
390-0051
390-0052
390-0065
390-0069 [F]
390-0109 [F]
390-0110
390-0111
SG-ARY154A-218R4 [S] 596-2986 StorEdge D1000 12-Slot Rackmount
218GB (12 × 18.2GB) 10000 RPM
540-4178 [F]

A1000/D1000 FRU
w/ 1" Bracket 540-3024
w/ Plate 340-4288
390-0002 [F]
390-0006
390-0038 [F]
390-0043
390-0048
390-0066
390-0085 [F]
SG-ARY173A-436R4 [S] 596-2987 StorEdge D1000 12-Slot Rackmount
436GB (12 × 36.4GB) 10000 RPM
540-4520 [F]

A1000/D1000 FRU
w/ 1" Bracket 540-3024
w/ Plate 340-4288
or Plate 340-6640
390-0050 [F]
390-0051
390-0052
390-0065
390-0069 [F]
390-0109 [F]
390-0110
390-0111
SG-DSK010C-18G [S] 599-2326 StorEdge UniPack - 18.2GB 10000 RPM 540-4305
Disk Drive Assembly
390-0002 [F]
390-0038 [F]
390-0060 [F]
X9645A [S] 595-5120 StorEdge UniPack tray n/a 540-3564
Ethernet
Option # Top Level
Part #
Manufacturing
Part #
Description
X1044A [S] 605-1591 375-0002 [F] Gigabit Ethernet (GBE/P) 1.0
X1045A [S] 605-1592 375-0003 [F] Gigabit Ethernet (GBE/S) 1.0
X1049A [S] 605-1597 501-5443 [F] Sun Quad FastEthernet (SQFE/S) 2.0
X1059A [S] 605-1535 501-2919 [F] SunFastEthernet Adapter 2.0 (Colossus Lite)
X1140A [S] 605-1602 501-4375 [F] Gigabit Ethernet (GBE/S) 2.0
X1141A [S] 605-1601 501-4373 [F] Gigabit Ethernet (GBE/P) 2.0
X1151A [S] 595-5773 501-5524 [F] Sun GigaSwift Ethernet MMF
X2721A [S] 595-4945 370-3795 [F] SuperStack II Entry Hub
X2722A [S] 595-5205 370-3795 [F] SuperStack II Entry Hub
X3151A [S] 595-5773 501-5524 [F] Sun GigaSwift Ethernet MMF
Fibre Channel
Option # Top Level
Part #
Manufacturing
Part #
Description
X6727A 595-5853 375-3030 [F] PCI Dual FC Network Adapter+
X6757A 595-5943 375-3048 [F] SBus Dual FC Network Adapter
SG-XPCI1FC-QF2 * 595-6425 375-3102 [F] 2GB PCI Single FC Network Adapter
SG-XPCI2FC-QF2 * 595-6426 375-3108 [F] 2GB PCI Dual FC Network Adapter
SG-XPCI1FC-QL2 594-2466 375-3383 [F] 2GB PCI-X Single FC Host Adapter,
X1057A [S] 595-3213 501-2553 Fibre Channel Host Adapter (FC25/S)
X6730A [S] 595-4303 540-2989
501-5266 [F]
FC-AL SBus Host Adapter (FC100/S)
X6746A [S] 595-5816 540-4372 [F] StorEdge Network FC Switch-8
X6767A [S]* 595-6425 375-3102 [F] 2GB PCI Single FC Network Adapter
X6768A [S]* 595-6426 375-3108 [F] 2GB PCI Dual FC Network Adapter
X6799A [S] 595-5830 375-3019 [F] PCI Single FC Host Adapter
* X6767A changed to SG-XPCI1FC-QF2 and X6768A changed to SG-XPCI2FC-QF2 in July 2003
I/O Boards
Option # Top Level
Part #
Manufacturing
Part #
Description Previous
Part #
2730A [S] 596-2148 501-4478 [F] SBus I/O Board 501-4349
2731A [S] 596-2294 501-4830 [F] PCI I/O Board 500-4779
501-4777
501-4778
PCI I/O Riser Board (3.3V)
PCI I/O Riser Board (5V)
n/a
n/a
Memory
Option # Top Level
Part #
Manufacturing
Part #
Option Description
X7022A [S] 595-3869 501-2653 [F] (32MB) 256 MB (8 × 32MB DIMMS)
X7023A [S] 595-3870 501-2654 [F] (128MB) 1 GB (8 × 128MB DIMMS)
X7025A [S] 595-4625 501-4776 [F] E10000 Memory Board
Power - DC
Option # Top Level
Part #
Manufacturing
Part #
Description
X9685A [S] 595-4628 300-1430 [F] Sun Type A135 2000 Watt Power Supply
Power - AC
Option # Top Level
Part #
Manufacturing
Part #
Description
X3875A [S] 595-4624 540-3441 [F] AC Input Module
n/a AC Input Module Power Requirements
9620A [S] 596-2453 300-1403 [F] 2nd AC Power Sequencer 230V
(standard on newer models)
n/a AC Power Sequencer Power Requirements
X9681A 595-4627 540-3440 [F] Remote Power Control Module
SCSI
Option # Top Level
Part #
Manufacturing
Part #
Description
X1018A [S] 605-1568 501-2739 [F] Single-Ended Fast/Wide SCSI/FastEthernet (SunSwift)
X1052A [S] 595-2731 501-1902 [F] Fast Differential SCSI-2/Buffered Ethernet Card (DSBE/S)
X1053A [S] 595-2724 501-2015 [F] Fast SCSI-2/Buffered Ethernet Card (FSBE/S)
X1062A [S] 595-3257 370-1704 [F] Differential Fast/Wide SCSI-2 Host Adapter (DWIS/S)
X1063A [S] 595-3258 370-1703 [F] Single-Ended Fast/Wide SCSI-2 Host Adapter (SWIS/S)
X1065A [S] 595-4187 370-2443 [F] Differential Ultra/Wide SCSI Host Adapter (UDWIS/S)
X2222A [S] 595-5624 501-5727 [F] Dual Ultra-2 SCSI/Dual FastEthernet PCI Adapter
System Board
Option # Top Level
Part #
Manufacturing
Part #
Description
2761A [S] 596-2388 501-5693 [F] E10000 System Board (CIC2)
X2720A [S] 595-4619 501-4345 [F] E10000 Control Board
X2721A [S] 595-4945 501-4345 [F] E10000 Control Board
X2722A [S] 595-5205 501-5494 [F] E10000 Control Board
X2760A [S] 595-4621 501-4903 [F] E10000 System Board
X2761A [S] 595-4947 501-5240 [F] E10000 System Board
n/a n/a 501-6336 [F] E10000 System Board
n/a n/a 501-4347 [F] E10000 System Board
n/a n/a 501-4786 [F] E10000 System Board
n/a n/a 501-4839 [F] E10000 Control Board
n/a n/a 501-5278 [F] E10000 System Board
n/a n/a 501-5279 [F] E10000 System Board
System Service Processor (SSP)
Option # Manufacturing
Part #
Description
X2750A [S] 603-2997 E10000 SSP (SPARCstation 5)
X2751A [S] 600-5471 E10000 SSP (Ultra 5)
X2753A [S] 600-5931 E10000 SSP (Ultra 5+)
X2754A [S] 600-6466 E10000 SSP (Ultra 5+)
X2755A [S] 600-7415 E10000 SSP (Enterprise 250)
X2757A [S] 602-2438 E10000 SSP (Sun Fire V120)

Table Legend
[F] = Field Replaceable Unit (FRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system



Exploded View



Table Legend
[F] = Field Replaceable Unit (FRU)

CODE
MANUFACTURING
PART #
DESCRIPTION
1 540-3059 Processor Cabinet
2 340-4526
340-4538
Flat Side Panel (Option 9693)
Flat Side Panel without Logo
3 540-3066 [F] Circuit Breaker (×11 on each side)
4 350-1153
350-1184
Curved Side Panel ("Styling Panel")
Curved Side Panel without Logo
5 501-4365 [F] Fan Tray Centerplane
6 540-3543 Left Front/Rear Door
7
-
540-3542
340-4537
Right Front/Rear Door
Front/Rear Door Foam Air Filter
8 540-3065 [F]
540-3409 [S] [F]
540-3075 [F]
Fan Tray
Fan Tray (Option 9671)
Fan Tray Filler Panel
9 540-3060 [F]
540-3069 [F]
Rear AC/DC Power Shelf (SYS 0-7, FAN 0-1)
Front AC/DC Power Shelf (SYS 8-15, FAN 2-3)
NS
NS
370-2845
555-1897 [F]
Card Cage Air Filter
Card Cage Air Filter Kit with 8× 370-2845
NS 370-2887 Centerplane Removal Handle Set
NS 540-3063 [F] System Board Filler Panel
NS 540-3064 [F] Control Board Filler Panel
NS 540-3068 Remote Power Control Module Shelf
NS 530-2265 [F] AC Power Cord, Harting Han 6HsB to NEMA L6-30P
NS 530-2266 AC Power Cord, Harting Han 6HsB to IEC309
NS 530-2567 [F] AC Power Cord, Harting Han 6HsB to NEMA L6-30P
NS 530-2568 AC Power Cord, Harting Han 6HsB to IEC309
NS 530-2379 AC Y Power Cord, NEMA L6-30P, 20' (obsolete)
NS 530-2380 AC Y Power Cord, IEC309 (obsolete)
NS 530-2391 [F] 48Vdc Front Power Shelf to Rear Power Shelf Cable, .3M
NS 530-2392 [F] 48Vdc Cardcage to Power Shelf Cable, 610 mm
NS 530-2393 [F] 48Vdc Cardcage to Power Shelf Cable, 1270 mm
NS 530-2394 [F] Cardcage Sense Cable, .9M
NS 530-2395 [F] Cardcage Sense Cable, 1.3M
NS 530-2396 [F] Centerplane and Upper Fan Power Cable
NS 530-2397 [F] Fan Signal Ribbon Cable
NS 530-2398 [F] Fan Sense Ribbon Cable
NS 530-2399 [F] Lower Fan Power Cable
NS 530-2400 [F] Control Board to Remote Power Control Cable, 3M
NS 530-2401 [F] Control Board to Remote Power Control Cable, 1.5M
NS 530-2402 [F] AC Sequencer to Remote Power Control Cable, .5M
NS 530-2403 [F] AC Sequencer to Remote Power Control Cable, 6M
NS 530-2475 Internal Power Shelf Circuit Breaker Cable
NS 530-2476 Internal Power Shelf Cable, 305 mm
NS 530-2477 Internal Power Shelf Cable, 660 mm
NS 530-2503 [F] AC Y Power Cord, NEMA L6-30P, 14.75' (obsolete)
NS 530-2802 Dual Power Option 48Vdc Cable
NS 530-2880 Dual Power Option Status Module I/O Cable
NS 530-2993 [S] [F] AC Y Power Cord, NEMA L6-30P, 14.75', Option 3865
NS 530-2994 [S] AC Y Power Cord, IEC309, Option 3851
NS 540-4387 Dual Power Option Status Module
NS
-
-
565-1673 [F]
340-2348 [F]
330-1265
SBus Accessory Kit
Bracket (×5)
Handle (×5)
NS 595-5120 UniPack Mounting Tray Option X9645A

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback