Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge L25 Tape Library - Full Components List

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
System Notes:
Technical support of the Sun StorEdge L25/L100 tape libraries was supplied by Quantum until July 31st 2008. The L25 reached EOSL in August 2008.

Cables
Option # Manufacturing
Part #
Description Previous
Part #
X1136A 530-2982 [F] Ultra-3 SCSI cable, VHDCI/VHDCI, 0.8M n/a
X9715A 537-1020 [F] Fibre Optical Cable SC/SC, 5M n/a
X978A 537-1006 [F] Fibre Channel Optical Cable 50/125 Multimode, 15M n/a
X3830A [S] 530-2454 [F] External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 4M n/a
X3831A [S] 530-2455 [F] External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 10M n/a
X9723A [S] 537-1033 [F] Fibre Channel Optical Cable LC/SC, 5M n/a
X9724A [S] 537-1034 [F] Fibre Channel Optical Cable LC/SC, 15M n/a
X9733A [S] 537-1042 [F] Fibre Channel Optical Cable LC/LC, 5M n/a
X9734A [S] 537-1043 [F] Fibre Channel Optical Cable LC/LC, 15M n/a
X9735A [S] 537-1053 [F] Fibre Channel Optical Cable LC/SC, 25M n/a
X9736A [S] 537-1051 [F] Fibre Channel Optical Cable LC/LC, 25M n/a
X9737A [S] 537-1055 [F] Fibre Channel Optical Cable LC/SC, 50M n/a
X9738A [S] 537-1052 [F] Fibre Channel Optical Cable LC/LC, 50M n/a
X979A [S] 530-1886 [F] [S] External SCSI Cable, HD68 to HD68, 12M n/a
3 Option is a 4 pack
Communication
Option # Manufacturing
Part #
Description Previous
Part #
SG-XMGMTCARD-MOD [S] 380-0686 Management Card n/a
SG-XMGMTCARDL-MOD [S] 380-0894 Management Card for LVD L25-L100 n/a
Fibre Channel
Option # Manufacturing
Part #
Description Previous
Part #
SG-XPCI1FC-QF4 Price 375-3354 4Gb PCI-X Single FC Host Adapter, n/a
SG-XPCI2FC-QF4 Price 375-3294 4Gb PCI-X Dual FC Host Adapter, n/a
SG-XPCIE1FC-QF4 Price 375-3355 4Gigabit/Sec PCI Express Single FC Host Adapter, n/a
SG-XPCIE2FC-QF4 Price 375-3356 4Gigabit/Sec PCI Express Dual FC Host Adapter, n/a
X6731A 370-2303 [F] FC-AL SW-GBIC Module n/a
SG-XFC420CARD-MOD [S] 380-0812 Fibre Channel / LVD Internal Bridge n/a
SG-XPCI1FC-EM2 [S] 375-3304 2Gb PCI-X Single FC Host Adapter, n/a
SG-XPCI1FC-QL2 [S] 375-3383 2Gb PCI-X Single FC Host Adapter, n/a
SG-XPCI1FC-QLC [S] 375-3253 Entry-Level 2Gb PCI-X Single FC Host Adapter n/a
SG-XPCI1FC-QLC-Z [S] 375-3364 Entry-Level 2Gb PCI-X Single FC Host Adapter, n/a
SG-XPCI2FC-EM2 [S] 375-3305 2Gb PCI-X Dual FC Host Adapter, n/a
SG-XPCI2FC-QF2-Z [S] 375-3363 2Gb PCI/PCI-X Dual FC Host Adapter, n/a
  • 240-4839
  • Low Profile Bracket,
n/a
X6727A [S] 375-3030 PCI Dual FC Host Adapter+, L n/a
X6757A [S] 375-3048 SBus Dual FC Network Adapter n/a
X6767A 4 [S] 375-3102 2Gb PCI Single FC Host Adapter n/a
X6768A 5 [S] 375-3108 2Gb PCI/PCI-X Dual FC Host Adapter n/a
  • 240-4839
  • Low Profile Bracket,
n/a
X6799A [S] 375-3019 6 PCI Single FC Host Adapter n/a
n/a 370-5211 [F] 2Gbps Short Wave SFP n/a
n/a 371-0099 [F] 2Gbps Short Wave SFP n/a
4 X6767A changed to SG-XPCI1FC-QF2 in July 2003
5 X6768A changed to SG-XPCI2FC-QF2 in July 2003
6 375-3019 with SC connector is no longer available. The substitute adapter uses a smaller LC connector.
NOTE: For FRU/CRU status, see host system's Full Components List.
Miscellaneous
Option # Manufacturing
Part #
Description Previous
Part #
SG-XLIBCOV-L25 [S] 380-0684 L25 Cosmetic Cover/Feet n/a
SG-XRACKIT-MOD [S] 380-0957 Universal Rackmount Kit n/a
SG-XSTACK2-MOD [S] 380-0689 StackLink 2-L25, Connects 2 L25 libraries n/a
SG-XSTACK5-MOD [S] 380-0690 StackLink 5-L25/L100, Connects up to 5 L25 libraries or 1 L100 and 1 L25 library n/a
SG-XSTACK7-MOD [S] 380-0691 StackLink 7-L25/L100, Connects up to 7 L25 libraries or 2 L100 libraries, or 1 L100 and up to 3 L25 libraries. n/a
n/a 380-0797 StackLink Common n/a
Rack
Option # Manufacturing
Part #
Description Previous
Part #
SG-XSWBRO3200-RK 370-5946 Brocade 3200 Rack Mount Kit n/a
Removable Media
Option # Manufacturing
Part #
Description Previous
Part #
SG-MEDLTO1-20B 390-0225 LTO1 100GB Data Cartridge (Package of 20) n/a
SG-MEDLTO2-20B 390-0226 LTO2 200GB Data Cartridge (Package of 20, Barcoded) n/a
SG-MEDLTOCL-10B 390-0228 LTO Cleaning Cartridges (Package of 10, Barcoded) n/a
SG-MEDSDLT1-20B 7 390-0229 SDLT 1 110/160GB Data Cartridge (Package of 20) n/a
SG-XMEDLTO3-10 8 390-0224 LTO3 400GB Non-barcoded Data Cartridge (Package of 10) n/a
SG-MEDSDLTCL-10B 9 [S] 390-0230 [S] SDLT Cleaning Cartridges (Package of 10) n/a
SG-XMAGDLT-MOD [S] 380-0687 DLT Magazine n/a
SG-XMEDDLTCIV-10 10 [S] 370-2188 [S] Digital Linear Tape (DLT) Compact IV Data Cartridge n/a
SG-XMEDDLTCL-10 11 [S] 370-2189 Digital Linear Tape (DLT) Cleaning Cartridge n/a
SG-XMEDLTO100GB-10 12 [S] 390-0087 [S] LTO 100GB Data Cartridge, for LTO1 or LTO2 Drives n/a
SG-XMEDLTO200GB-10 [S] 390-0147 [S] LTO2 200GB Data Cartridge (Package of 10, Non-barcoded) n/a
SG-XMEDLTOUNVCL-10 [S] 390-0134 [S] LTO Cleaning Cartridge (Package of 10, Non-barcoded) n/a
SG-XMEDSDLT220-10 13 [S] 390-0135 [S] SDLT 160GB Data Cartridge n/a
SG-XMEDSDLT2D-20 [S] 390-0163 [S] SDLT 600 300GB Data Cartridges (Package of 20, Non-barcoded) n/a
SG-XMEDSDLTCL-10 [S] 390-0140 [S] SDLT Cleaning Cartridge, SDLT Cleaning Cartridge (Package of 10, Non-barcoded) n/a
SG-XTAPDLT8-MOD [S] 380-0681 DLT8000 High Voltage Differential (HVD) Tape Drive n/a
SG-XTAPLTO-MOD [S] 380-0683 LTO High Voltage Differential (HVD) Tape Drive n/a
SG-XTAPLTO2LVD-MOD [S] 380-0892 LTO2 Low Voltage Differential (LVD) SCSI Drive for L25/L100 n/a
SG-XTAPLTO3LVD-MOD [S] 380-1196 LTO3 Low Voltage Differential (LVD) SCSI Drive for L25/L100 n/a
SG-XTAPLTOLVD-MOD [S] 380-0811 LTO1 Low Voltage Differential (LVD) SCSI Drive for L25/L100 n/a
SG-XTAPSDLT2-MOD [S] 380-0682 SDLT 220 High Voltage Differential (HVD) Tape Drive n/a
SG-XTAPSDLT3-MOD [S] 380-0820 SDLT320 Low Voltage Differential (LVD) Tape Drive n/a
SG-XTAPSDLT600-MOD [S] 380-0980 SDLT600 Low Voltage Differential (LVD) drive n/a
7 Native capacity dependent upon drive type, 110GB per cartridge for SDLT 220, 160GB per cartridge for SDLT 320.
8 Backward read/write compatible with LTO2; backward read compatible with LTO1.
9 SDLT cleaning cartridges for all SDLT drive types.
10 Option is a 10 pack
11 Option is a 10 pack
12 Option is a 10 pack
13 Option is a 10 pack
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
SG-XPCIE2SCSIU320Z Price 375-3357 Dual-Channel Ultra320 LVD SCSI PCI Express Adapter, n/a
SGXPCI1SCSILM320-Z Price 375-3366 PCI/PCI-X Single Ultra320 SCSI Adapter n/a
SGXPCI2SCSILM320-Z 15 Price 375-3365 14 PCI Dual Ultra320 SCSI Adapter, L n/a
SG-XPCI2SCSI-LM320 [S] 375-3191 PCI/PCI-X Dual Ultra320 SCSI Adapter n/a
X1065A [S] 370-2443 Differential Ultra/Wide SCSI Host Adapter (UDWIS/S) (HVD) n/a
X6541A [S] 375-0006 Dual Differential Ultra/Wide SCSI (UDWIS/P)(HVD) n/a
X6749A [S] 375-0119 Dual Differential Ultra/Wide SCSI, (UDWIS/cPCI)(HVD) n/a
X6758A [S] 375-3057 16 PCI Dual Ultra3 SCSI Host Adapter (LVD) n/a
14 Ultra320 SCSI HBA (375-3365-01 REV 52) FCode 1.13 fails to work on all Sun Platforms, replace it with 375-3365-02 REV 50. See Problem article 1013105.1.
15 This HBA requires the SDLT320, LTO1, or LTO2 tape drive within the Sun StorEdge L25/L100 Tape library.
16 The necessary drivers (SUNWqus, SUNWqusu, SUNWqusx, & SUNWqusux) and patches for this product are not included in Solaris 8 or 9, but must be downloaded. Please see How To article 1018123.1 for details.
NOTE: For FRU/CRU status, see host system's Full Components List.
Switch/Hub
Option # Manufacturing
Part #
Description Previous
Part #
SG-XSWMD4500-8P 370-6085 McData Sphereon 4500 24-port Switch with 8 ports activated n/a
SG-XSWMD4500-UPG n/a McData Sphereon 4500 8 port activation license key, activates 8 additional ports n/a
SG-XSWQLG5200-20P 18 370-7694 17 QLogic 5200 Switch (20 ports active) n/a
SG-XSWQLG5200-8P 19 370-7664 [F] QLogic 5200 Switch (8 ports active) n/a
SG-XSW16-2GB [S] 540-5404 [F] Sun StorEdge Network 2GB FC Switch-16 n/a
SG-XSW16-32P [S] 540-4751 [F] Sun StorEdge Network FC Switch-16 n/a
SG-XSW8-2GB [S] 540-5554 [F] Sun StorEdge Network 2GB FC Switch-8 n/a
SG-XSWBRO3200 [S] 370-5769 [F] Brocade Silkworm 3200 8-Port FC Switch n/a
SG-XSWBRO3250 20 [S] 370-6824 [F] Brocade 3252 Value Line 8-Port FC Switch n/a
370-7047 Brocade 3250 8-Port FC Switch n/a
SG-XSWBRO3800 [S] 370-4949 [F] [S] Brocade Silkworm 3800 16-Port FC Switch n/a
SG-XSWBRO3850 21 [S] 370-6826 [F] Brocade 3852 Value Line 16-Port FC Switch n/a
370-7048 Brocade 3850 16-Port FC Switch n/a
SG-XSWBRO3900 [S] 370-6078 [F] Brocade Silkworm 3900 32-Port FC Switch n/a
SG-XSWBRO4100-16P 22 [S] 370-7756 [F] Brocade Silkworm 4100 FC Switch (16 Ports) n/a
SG-XSWBRO4100-32P 23 [S] 370-7770 Brocade Silkworm 4100 FC Switch (32 Ports) n/a
SG-XSWMD4300-12P [S] 370-6169 [F] McData Sphereon 4300 12-port Switch n/a
X6746A [S] Redundant FC 8-port Switch Option (two 8-port switches)
540-4372 [F] StorEdge Network FC Switch-8 n/a
17 Sixteen 2-Gb ports and four 10-Gb ports activated.
18 Connection to the Sun StorEdge L25/L100 Tape library requires the use of a Fibre Bridge product.
19 Connection to the Sun StorEdge L25/L100 Tape library requires the use of a Fibre Bridge product.
20 Connection to the Sun StorEdge L25/L100 Tape library requires the use of a Fibre Bridge product.
21 Connection to the Sun StorEdge L25/L100 Tape library requires the use of a Fibre Bridge product.
22 Connection to the Sun StorEdge L25/L100 Tape library requires the use of a Fibre Bridge product.
23 Connection to the Sun StorEdge L25/L100 Tape library requires the use of a Fibre Bridge product.

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

No Artwork Currently Available

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
NS 370-7587 [F] HD68 LVD/SE Terminator, Amphenol 497040001 (not included)
NS 371-1969 [F] HD68 LVD/SE Terminator, Amphenol 497040001, L
NS 595-6870 L25 SDLT LVD Base Unit, Option SG-XLIBL25SDL-BASE
NS
  • 380-0821
  • L25 SDLT LVD Base Unit
NS 595-7004 L25 LTO LVD Base Unit, Option SG-XLIBL25LLV-BASE
NS
  • 380-0893
  • L25 LTO LVD Base Unit
NS 595-6546 [S] L25 DLT Base Unit, Option SG-XLIBL25D-BASE [S]
NS
  • 380-0677
  • L25 DLT Base Unit
NS 595-6547 [S] L25 LTO HVD Base Unit, Option SG-XLIBL25L-BASE [S]
NS
  • 380-0678
  • L25 LTO HVD Base Unit
  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback