Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1006686.1 : Sun StorEdge[TM] 5310, 5310C, 5320, 5320C: Associating ISP with physical port position
PreviouslyPublishedAs 209320 Description On occasion you may need to associate the ISP number with the physical position on the back of the NAS head. A typical message that may be seen when a cable is pulled: 5/08/06 14:42:31 I isp1: NO LINK... check cables; power may be down, FW_state= Waiting for AL_PA Steps to Follow Telnet to the NAS array to get to the prompt. Type: `hbainfo` to correlate the isp number with the WWN se5310a-usan > hbainfo isp1: F/W Revision 3.3.18, Topology Private Loop, On_Fabric 0 Node WWN: 0x200000E0.8B1A0BC2, Port WWN: 0x210000E0.8B1A0BC2 <--------- RAID Controller Info: SID: 123, LoopID: 0x7B, PortID: 0x4 Fabric: 0, Role: Target, Logged_in: 0 Node WWN: 0x200400A0.B816C83D, Port WWN: 0x200400A0.B816C83E Vendor: SUN, Product: CSM100_R_FC Serial No: 1T44156035, Product Revision: 0612 isp2: F/W Revision 3.3.18, Topology Private Loop, On_Fabric 0 Node WWN: 0x200000E0.8B3A0BC2, Port WWN: 0x210100E0.8B3A0BC2 RAID Controller Info: SID: 2, LoopID: 0x2, PortID: 0xE4 Fabric: 0, Role: Target, Logged_in: 0 Node WWN: 0x200600A0.B8167B8A, Port WWN: 0x200700A0.B8167B8B Vendor: SUN, Product: CSM100_R_FC Serial No: 1T42568565, Product Revision: 0612 isp3: F/W Revision 3.3.18, Topology Private Loop, On_Fabric 0 Node WWN: 0x200000E0.8B1A4C93, Port WWN: 0x210000E0.8B1A4C93 RAID Controller Info: SID: 2, LoopID: 0x2, PortID: 0xE4 Fabric: 0, Role: Target, Logged_in: 0 Node WWN: 0x200400A0.B816C83D, Port WWN: 0x200500A0.B816C83E Vendor: SUN, Product: CSM100_R_FC Serial No: 1T44155876, Product Revision: 0612 isp4: F/W Revision 3.3.18, Topology Private Loop, On_Fabric 0 Node WWN: 0x200000E0.8B3A4C93, Port WWN: 0x210100E0.8B3A4C93 RAID Controller Info: SID: 2, LoopID: 0x2, PortID: 0xE4 Fabric: 0, Role: Target, Logged_in: 0 Node WWN: 0x200600A0.B8167B8A, Port WWN: 0x200600A0.B8167B8B Vendor: SUN, Product: CSM100_R_FC Serial No: 1T42680849, Product Revision: 0612 The isp# association to its physical position along with it boot up order is as below (this information is collected from a simple cable pull test). isp1 is lower right port (looking at the HBA from the back of the NAS head) After pulling lower right FC cable: ---------- 5/25/06 16:10:01 I isp1: NO LINK... check cables; power may be down, FW_state= Waiting for AL_PA 05/25/06 16:10:01 I isp1: LIP Received 05/25/06 16:10:01 I isp1: Loop UP 05/25/06 16:10:01 I isp1: Port Database Changed 05/25/06 16:10:01 I 2Gb link speed/s 05/25/06 16:10:01 I Loop ID 0, AL_PA 0xEF, Port ID 0xEF, Loop State 0x2, Topology 'Private Loop' 05/25/06 16:10:01 I Target 0 (Loop 0x0) Port ID 0xEF (role Initiator) Arrived Port WWN 0x210000E08B1A0BC2 Node WWN 0x200000E08B1A0BC2 <------- 05/25/06 16:10:04 I isp1: F/W Ready! 05/25/06 16:10:04 I >>> isp1: TID 11 scsi_adapter_attach SCANNING for LUNs... ---------- Product Sun StorageTek 5310 NAS Appliance Sun StorageTek 5310 NAS Gateway/Cluster System Sun StorageTek 5320 NAS Gateway/Cluster System Sun StorageTek 5320 NAS Appliance Sun StorageTek 5320 Sun StorageTek 5310 NAS Gateway System Internal Comments This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: [email protected] NAS, 5310, 5310C, hba, WWN, isp, cable, normalized, audited Previously Published As 85762 Change History Date: 2007-10-03 User Name: 7058 Action: Approved Comment: Updates OK to publish. Version: 7 Date: 2007-10-02 User Name: 7058 Action: Accept Comment: Version: 0 Date: 2007-10-02 User Name: 160775 Action: Approved Attachments This solution has no attachment |
||||||||||||
|