Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1004759.1 : Sun StorEdge[TM] 3000:Tech Tip:Access out of band (network)
PreviouslyPublishedAs 206608 Description Sun StorEdge[TM] 3320/3310/3510/3511:Tech Tip:Access out of band (network) Steps to Follow To access the Sun StorEdge[TM] 3320, 3310, 3510 and 3511 out of band from the command line, use the following: # sccli <ip-address or hostname of array) To run the 'se3k' extractor out of band, # se3kxtr -d <ip-address or name of array> -o -v This will run the se3kxtr out of band and Product Sun StorageTek 3510 FC Array Sun StorageTek 3310 SCSI Array Sun StorageTek 3511 SATA Array Sun StorageTek 3320 SCSI Array 3310, 3510, 3511, 3320 , out, of, band Previously Published As 71319 Change History Date: 2004-10-19 User Name: 7058 Action: Approved Comment: Added trademarking in first instance of product in text body. OK to publish. Short doc. Version: 2 Date: 2004-10-19 Attachments This solution has no attachment |
||||||||||||
|