Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1011864.1 : Sun StorEdge[TM] D1000 disk drive LED's flashing amber / green continuously
PreviouslyPublishedAs 216248 Symptoms All the disk drives in a D1000 disk array have their LED's flashing amber and green continuously. No other disk problems or errors are evident and performance seems normal. Resolution If SunVTS[TM] is run against a machine or domain with a D1000 disk array attached, the D1000 array may be left in such a state that the disk LED's flash amber and green continuously. There are no other adverse effects, but the D1000 array must then be power cycled to clear this condition. This is due to the SES driver being left in an unknown state by SunVTS after the diagnostic tests are aborted. Note: If the D1000 is configured in a split bus configuration and connected to two different hosts, only the disks attached to the host that ran SunVTS will have flashing amber / green LED's. Product Sun StorageTek D1000 Array Internal Comments For internal Sun use only. D1000, LED, flashing, amber, SunVTS, disk Previously Published As 48028 Change History Date: 2005-02-10 User Name: 31620 Action: Approved Comment: Verified Metadata Verified still correct for audience - free Checked review date 2006-02-09 Checked for TM - no new ones needed Publishing Version: 3 Date: 2005-02-10 User Name: 31620 Action: Accept Comment: Version: 0 Date: 2005-02-09 User Name: 18335 Action: Approved Comment: Looks fine. Version: 0 Product_uuid 2a753f90-0a18-11d6-96d0-f5e96014c515|Sun StorageTek D1000 Array Attachments This solution has no attachment |
||||||||||||
|