Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1007982.1
Update Date:2009-09-24
Keywords:

Solution Type  Problem Resolution Sure

Solution  1007982.1 :   Sun StorEdge[TM] 3310 without configured lun0 shows narrow channel setting.  


Related Items
  • Sun Storage 3310 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
211012


Symptoms
When connecting the Sun StorEdge[TM] 3310 to a host the host channel shows Width is narrow and speed shows Async setting.
sccli> sh ch
Ch  Type    Media   Speed   Width  PID / SID
--------------------------------------------
0  Drive   SCSI    80M     Wide     6 / 7
1  Host    SCSI    80M     Wide     0 / 1
2  Drive   SCSI    ASYNC   Narrow   6 / 7
3  Host    SCSI    ASYNC   Narrow   1 / 0
6  Drive   Unknown ASYNC   Narrow  N/A / N/A
7  Host    LAN     N/A     Serial  N/A / N/A


Resolution
In this case it was found the, there is no lun '0' configured. Lun 0 is a SCSI requirement and must exist for sd to work properly.


See Document ID:   <Document: 1017707.1>
Title:     Logical Unit Number(LUN) 0 , A SCSI Requirement
Once lun 0 is mapped, the channel changes to "80M/Wide" or appropriate setting. Hence we must map a lun 0 for proper operation of the 3310. This needs to be done on all host channels.


Product
Sun StorageTek 3310 SCSI Array

Previously Published As
82757
narrow, async, 3310, channel, wide, width, speed
Product_uuid
3db30178-43d7-4d85-8bbe-551c33040f0d|Sun StorageTek 3310 SCSI Array

Change History
Date: 2005-10-14
User Name: 25440
Action: Approved
Comment: Publishing.
Version: 3
Date: 2005-10-14
User Name: 25440
Action: Accept
Comment:
Version: 0
Date: 2005-10-14

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.