Solution Type Problem Resolution Sure Solution 1007691.1 : [3310] ssmon can generate ASC: 0x29 (power on, reset, or bus reset occurred)
PreviouslyPublishedAs 210658
Applies to:Sun Storage 3310 ArraySun Storage 3320 SCSI Array - Version: Not Applicable and later [Release: N/A and later] All Platforms SymptomsIf you have the following messages in the host messages, 3 times a day and more when the I/O activity increases, they can be generated by ssmon daemon or ssconsole GUI (graphical user interface) when "in-band" monitoring is configured.Jan 3 08:02:59 bretagne scsi: [ID 107833 kern.warning] WARNING: /pci@1d,700000/pci@2/scsi@5/sd@1,4 (sd154): Jan 3 08:02:59 bretagne Error for Command: read Error Level: Retryable Jan 3 08:02:59 bretagne scsi: [ID 107833 kern.notice] Requested Block: 533456 Error Block: 533456 Jan 3 08:02:59 bretagne scsi: [ID 107833 kern.notice] Vendor: SUN Serial Number: 25AFBEBB-01 Jan 3 08:02:59 bretagne scsi: [ID 107833 kern.notice] Sense Key: Unit Attention Jan 3 08:02:59 bretagne scsi: [ID 107833 kern.notice] ASC: 0x29 (power on, reset, or bus reset occurred), ASCQ: 0x0, FRU: 0 x0 Jan 3 11:16:33 bretagne scsi: [ID 107833 kern.warning] WARNING: /pci@1d,700000/pci@2/scsi@5/sd@1,4 (sd154): Jan 3 11:16:33 bretagne Error for Command: read(10) Error Level: Retryable Jan 3 11:16:33 bretagne scsi: [ID 107833 kern.notice] Requested Block: 136343840 Error Block: 136343840 Jan 3 11:16:33 bretagne scsi: [ID 107833 kern.notice] Vendor: SUN Serial Number: 25AFBEBB-01 Jan 3 11:16:33 bretagne scsi: [ID 107833 kern.notice] Sense Key: Unit Attention Jan 3 11:16:33 bretagne scsi: [ID 107833 kern.notice] ASC: 0x29 (power on, reset, or bus reset occurred), ASCQ: 0x0, FRU: 0 x0 Jan 3 14:28:23 bretagne write: [ID 201458 auth.crit] /dev/dtremote in utmpx is not a tty Jan 3 14:48:56 bretagne su: [ID 810491 auth.crit] 'su root' failed for 98000 on /dev/pts/9 Jan 3 22:36:59 bretagne scsi: [ID 107833 kern.warning] WARNING: /pci@1d,700000/pci@2/scsi@5 Jan 3 22:36:59 bretagne Error for Command: read(10) Error Level: Retryable Jan 3 22:36:59 bretagne scsi: [ID 107833 kern.notice] Requested Block: 139878414 Error Block: 139878414 Jan 3 22:36:59 bretagne scsi: [ID 107833 kern.notice] Vendor: SUN Serial Number: 25AFBEBB-01 Jan 3 22:36:59 bretagne scsi: [ID 107833 kern.notice] Sense Key: Unit Attention Jan 3 22:36:59 bretagne scsi: [ID 107833 kern.notice] ASC: 0x29 (power on, reset, or bus reset occurred), ASCQ: 0x0, FRU: 0 Notice : "in-band" means ssmon or ssconsole communicate through the SCSI connection, vs out-of-band through the network connection Changes{CHANGE}Cause{CAUSE}SolutionBefore planning any hardware replacement, it's compulsory to apply the minimumlevel of patch for the I/O drivers on the host, and upgrade the firmware of the array controllers and internal disks before verifing the ssmon configuration as described below: 1) Verify software/firmware: o All array firmwares should be at the latest revisions: 4.23C for 3310, and 4.21E for 3320 Controller firmware (minimum requirement), 2) Check if the ssagent is configured "out-of-band": Edit the ssagent configuration file: /var/opt/SUNWsscs/ssagent/ssagent.cfg o Verify the value of variable PRIAGENT_OVER_INBAND A value of 0 for PRIAGENT_OVER_INBAND indicates that the direct "in-band" scsi 3) How to configure ssagent "out-of-band": When the network interface of the SE3310 or SE3320 is configured to a LAN. There are two methods: o By command line: a) Stop the ssagent: /etc/init.d/ssagent stop b)Edit the file: /var/opt/SUNWsscs/ssagent/ssagent.cfg PRIAGENT_OVER_INBAND=1 c) Check that the 2 following lines exist for each array in this file: PRIAGENT_IP=xxx.xxx.xxx.xxx PRIAGENT_PORT=58632 d) Verify the network interface of [3310] is correctly configured in the ssagent.cfg file: e)Start the ssagent: /etc/init.d/ssagent start o By the GUI (sscs): Follow the steps described in the Sun Storedge 3000 Family Configuration If "in-band" monitoring is the only alternative for a particular array, you can stop the ssagent software: /etc/init.d/ssagent stop and monitor for one week or more depending upon the frequency of the messages, Otherwise, if errors still occur, the cause is more complex and will need additional troubleshooting. For out-of-band it's recommended to configure the network interface of the array Attachments This solution has no attachment |
||||||||||||
|