Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1003771.1 : Sun StorEdge[TM] Diagnostic Reporter: "Server not online" error
PreviouslyPublishedAs 205306 Symptoms Sun StorEdge[TM] Diagnostic Reporter will not find a host server to login in to, Resolution Often the daemons are not loaded, or started in the wrong order. This may cause the daemons to contend with each other, and not allow 1. Stop the daemons: # /etc/init.d/ssagent stop # /etc/init.d/ssdgrptd stop 2. Start daemons in the order shown: # /etc/init.d/ssagent start # /etc/init.d/ssdgrptd start 3. Start Config Services Console # ssconsole 4. Start Diagnostic Reporter # ssdgrptui Product Sun StorageTek 3310 SCSI Array Sun StorageTek 3510 FC Array Sun StorageTek 3511 SATA Array Diagnostic Reporter, Minnow, SE3510, SE3310, SE3511 Previously Published As 83599 Change History Date: 2006-01-23 User Name: 18392 Action: Approved Comment: Added product name, trademarking, STM. Changed Audience to from Free to Contract, as per Fee vs. Free guidelines. Corrected spelling, did some re-wording and formatting for clarity and readability. Version: 3 Date: 2006-01-23 User Name: 18392 Action: Accept Comment: Version: 0 Date: 2006-01-23 User Name: 109562 Action: Approved Comment: Modifications made to : delineate steps and add descriptions reduce dialog in other areas Version: 0 Date: 2006-01-18 User Name: 120551 Action: Approved Comment: Will need to review for accuracy and VNC into hook and draw to see demo. Version: 0 Date: 2006-01-18 User Name: 120551 Action: Created Comment: Version: 0 Product_uuid 3db30178-43d7-4d85-8bbe-551c33040f0d|Sun StorageTek 3310 SCSI Array 58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array 9fdbb196-73a6-11d8-9e3a-080020a9ed93|Sun StorageTek 3511 SATA Array Attachments This solution has no attachment |
||||||||||||
|