Solution Type  Problem Resolution Sure

Solution  1003771.1 :   Sun StorEdge[TM] Diagnostic Reporter: "Server not online" error  


Related Items
  • Sun Storage 3510 FC Array
  •  
  • Sun Storage 3310 Array
  •  
  • Sun Storage 3511 SATA Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
205306


Symptoms

Sun StorEdge[TM] Diagnostic Reporter will not find a host server to login in to,
if the associated daemons are not properly loaded.



Resolution

Often the daemons are not loaded, or started in the wrong order.

This may cause the daemons to contend with each other, and not allow
Diagnostic Reporter to find a host server.

1. Stop the daemons:
     # /etc/init.d/ssagent stop
# /etc/init.d/ssdgrptd stop
2. Start daemons in the order shown: 
     # /etc/init.d/ssagent start
# /etc/init.d/ssdgrptd start
3. Start Config Services Console
     # ssconsole
4. Start Diagnostic Reporter
     # ssdgrptui 


Product
Sun StorageTek 3310 SCSI Array
Sun StorageTek 3510 FC Array
Sun StorageTek 3511 SATA Array

Diagnostic Reporter, Minnow, SE3510, SE3310, SE3511
Previously Published As
83599

Change History
Date: 2006-01-23
User Name: 18392
Action: Approved
Comment: Added product name, trademarking, STM. Changed Audience to from Free to Contract, as per Fee vs. Free guidelines. Corrected spelling, did some re-wording and formatting for clarity and readability.
Version: 3
Date: 2006-01-23
User Name: 18392
Action: Accept
Comment:
Version: 0
Date: 2006-01-23
User Name: 109562
Action: Approved
Comment: Modifications made to :

delineate steps and add descriptions
reduce dialog in other areas
Version: 0
Date: 2006-01-18
User Name: 120551
Action: Approved
Comment: Will need to review for accuracy and VNC into hook and draw
to see demo.
Version: 0
Date: 2006-01-18
User Name: 120551
Action: Created
Comment:
Version: 0
Product_uuid
3db30178-43d7-4d85-8bbe-551c33040f0d|Sun StorageTek 3310 SCSI Array
58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array
9fdbb196-73a6-11d8-9e3a-080020a9ed93|Sun StorageTek 3511 SATA Array

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback