Processor |
| Number |
1 or 2 |
| Architecture |
AMD Opteron Processor 200 Series
242 (1.6GHz), 244 (1.8GHz), 270 (2.0GHz), 248 (2.2GHz), 275 (2.2GHz), 250 (2.4GHz), 252 (2.6GHz) |
| Cache memory |
1 MB Level 2 |
|
Main Memory |
| Capacities |
4 DIMM slots per processor, 8 total slots per System Board
DDR1/333 ECC registered DIMMs (128 bit plus ECC databus)
512-MB, 1-GB, or 2-GB expansion
(16GB maximum when configured with 2 processors)
|
|
Standard Integrated Interfaces |
| Network |
Two 10/100/1000Base-T Ethernet ports |
| Network Management |
One dedicated 10/100Base-T Ethernet port with integrated 2 ports switch
for daisy-chaining |
| Serial |
One TIA/EIA-232-F asynchronous DB-9 port |
| SCSI |
Single Ultra320 SCSI interface, internal access only.
No external SCSI port. |
| USB |
One USB 1.1 port |
| Expansion bus |
Two internal PCI-X slots
- one full-length at 64-bit/133MHz (slot 0)
- one half-length at 64-bit/66MHz (slot 1)
|
|
Internal Mass Storage |
| Disks |
Up to two hot-swap Ultra320 SCSI Disks (36 or 73 GB, 10K RPM) |
| DVD or CD-ROM |
One Slim-line ATAPI DVD-ROM/Floppy or CD-ROM/Floppy (optional) |
|
Power Supplies |
| One power supply, maximum AC output 465W |
|
Environment |
| AC power |
90-264 V AC (47-63 Hz) |
| Temperature |
Single, non-rack system:
Operating: 10° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F) |
| Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing,
27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing,
38° C (100.4° F) max wet bulb |
| Altitude |
Single, non-rack system:
Operating: up to 3000 m (10,000 ft.), maximum ambient temperature
is derated by 1° C per 500 m above 500 m
Nonoperating: up to 12,000 m (40,000 ft.)
|
| Acoustic noise |
Single, non-rack system:
Less than 6.7 B sound power in ambient temperature of up to 24° C |
| Vibration |
Single, non-rack system:
.20 G, 5 to 500 Hz sine sweep |
| Shock |
Single, non-rack system:
5 G, 11 ms half-sine |
Regulations
Meets or exceeds the following requirements: |
| Safety |
IEC60950, UL/CSA60950, EN60950 |
| RFI/EMI |
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22 |
| Immunity |
EN55024 |
| Certifications |
Safety: cULus Mark, TUV GS Mark, CE Mark
EMC: CE Mark (93/68/EEC), FCC authorized Class A, VCCI, BSMI, CTICK |
|
Dimensions and Weight |
| Height |
43 mm (1.69 in.) |
| Width |
430 mm (16.94 in.) |
| Depth |
724 mm (28.5 in.) |
| Weight |
16 kg (35 lb.) (with packaging) |
|
Enclosure |
|
The Sun Fire V20z server can be mounted in industry standard 19-inch
equipment racks. (The new Compute Grid rack system base and Sun Fire V20z
compute servers will enable the installation of 32 1U units in the Sun
Rack 1000-38.)
The optional slide rail kit (X9267A, backward-compatible with X9274A)
is designed to enable Sun Fire V20z servers to be racked in a Sun Rack
1000-38 (also known as Sun Rack 1038) and third party EIA 310D compliant
racks which have mounting depths of 27-30 inches. Please note that not all
third party racks meet these parameters. The slides are useable on racks
with a rail-to-rail spacing of 26.88-30.63 inches.
The Sun Rack 1038 rail spacing, for example, is 27.00 inches. The
slide kit will include hardware that enables mounting to any of the
following types of rack rails:
6 mm threaded holes
#10-32 threaded holes
#10 clearance holes
The optional slide rail kit (X9267A) is a 4-point mounted slide rail
kit only. No other kits will be available to allow 2-point, front-mount,
nor mid-mount configuration.
|