   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Blade X6450 Server Module: Hardware Specifications

Note: Modular System (chassis) specifications are documented on the chassis specification page. Reference the Servers/Blade section of the Handbook's Systems List to find documentation on Modular Systems.
Processor
Number Up to four.
Architecture Type:Intel Xeon processors.
  • Model/Speed: E7220, 2-Core, 2.93 GHz, 80W
  • Model/Speed: L7345, 4-Core, 1.86 GHz, 50W
  • Model/Speed: L7445, 4-Core, 2.13 GHz, 50W
  • Model/Speed: E7320, 4-Core, 2.13 GHz, 80W
  • Model/Speed: E7340, 4-Core, 2.40 GHz, 80W
  • Model/Speed: E7440, 4-Core, 2.40 GHz, 90W
  • Model/Speed: L7455, 6-Core, 2.13 GHz, 65W
  • Model/Speed: E7450, 6-Core, 2.40 GHz, 90W
Cache Memory L2 Cache
Main Memory
Memory Type PC2-5300 DDR2 Fully Buffered DIMMs (FBDIMMs).
Capacities
  • Maximum memory: 192GB.
  • Total DIMM slots: 24.
  • DIMM sizes: 1GB, 2GB, 4GB and 8GB.
  • Install DIMMs in pairs of two beginning with A0/B0.
IDE Compact Flash 8GB Compact Flash Type II (supports Linux boot) is on the motherboard.
Optional Storage
Solid State Drives
  • 1 32GB solid state drive.
Management Environment
Sun Blade Server Module Service Processor (SP)
  • The SP is not a separate card. It is embedded on the motherboard.
  • The SP is installed with Lights-Out Manager (LOM), IPMI 2.0-compatible software.
  • Embedded Lights-Out Manager (ELOM) and Integrated Lights-Out Manager (ILOM) are supported.
  • The factory pre-configured LOM transitioned to ILOM in September 2008.
  • The SP card provides one 10/100 Management Ethernet Port to Midplane and the Chassis Monitoring Module (CMM). The DB9-to-RJ45 serial adapter cable provides DB9 serial access to the server module through an RJ45 connection.
  • LOM on the SP card can be accessed via the Dongle cable's DB9 connector to the Universal Connector Port (UCP) RJ45 connector on the front of the Sun Blade X6450.
  • The Dongle cable assembly is provided with the Sun Blade 6000 chassis and also orderable. Option X4621A.
  • The SP card and LOM provide the following:
    • A Browser User Interface (HTTP/HTTPS).
    • DMTF/CLP based CLI and SSH.
    • Support for RADIUS, LDAP, and MS Active Directory.
    • IPMI 2.0 (Host access through KCS and remote).
    • Compatibility for third-party SNMP system managers with requirements for SNMP (v1, v2C, v3).
    • Remote KVMS/Java Console (redirected Keyboard Video Mouse and Storage through a JAVA Application).
    • Support for Sun N1 System Manager.
Standard Integrated Interfaces
Universal Connector Port (UCP) The Dongle Cable Assembly (Option X4621A) that ships with the Sun Blade 6000 chassis connects to the UCP and provides the following:
  • VGA HD15 port to AST2000 video controller with 128MB of shared SDRAM.
  • 2 USB 2.0 ports.
  • DB9 serial port (for connection to SP LOM).
  • RJ45 port.
  • DB9F to RJ45F DCE Adapter.

Network Management Two 10/100Base-T Ethernet connection via midplane to the CMM. Only one connection (NET 0) is used.
Ethernet Two 10/100/1000Base-T Ethernet ports routed through midplane to 2 NEM slots.
PCI Interfaces with the Sun Blade Modular System (chassis)
  • I/O is offered in two form factors:
    • PCI Express ExpressModules (EM)
      and
    • PCI Express Network Express Modules (NEM).
  • Each Sun Blade X6450 has four, PCI Express links allocated to:
    • Two EMs (X8)
      and
    • Two NEMs (X4).
  • Each NEM has one link assigned to each server module. All server modules share the NEM. For example, Blade 0 has access to NEM 0/slot 0, and NEM 1/slot 0. Blade 1 to NEM 0/slot 1 and NEM 1/slot 1, etc.
  • EM slots are not shared between server modules. Each EM slot is specific to one server module.
Regulations
RoHS Compliance Level RoHS:YL

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.