Processor
Number One CPU
Architecture SPARC64 VII: 2.52GHz or 2.75GHz Dual or Quad Core processor, SPARC V9, ECC Protected
SPARC64 VII+: 2.86GHz Dual or Quad Core processor, SPARC V9, ECC Protected
Cache memory SPARC64 VII: 5MB Shared Level 2 on Chip Cache, 64KB I-Cache and 64KB D-Cache Level
SPARC64 VII+: 5.5MB Shared Level 2 on Chip Cache, 64KB I-Cache and 64KB D-Cache Level
Main Memory
Capacities

8GB (using 1GB DDR2 DIMMS) to 64GB (using 8GB DDR2 DIMMs), 8 slots per system. DIMM sizes: 1GB, 2GB, 4GB and 8GB.

Standard Interfaces
Ethernet 4 × integrated Gigabit Ethernet ports also 2 × 10/100 ethernet ports for accessing CLI and browser based interface on Extended System Control Facility (XSCF)
PCI-X / PCI-Express 4 × X8 PCI-E Slots
Serial One RJ45
USB One port on XSCF that field engineer can use to download hardware information
SAS One external SAS port (two-lane)
Internal Mass Storage
Disks Up to 4 internal 146GB SAS Disk Drives
DVD-ROM 1 DVD-RW
Tape None
Power Supplies
Type 1 or 2 × 100-240 VAC, 565W, 1-phase (50-60Hz), 12 amp per power cord
Output 600 Watts (2 power cords)
Environment
AC Power 100-240VAC
DC Power ~48V/~60V
Input power 100 127 VAC
200 240 VAC
Power Draw 470 Watts (2 power cords)
Maximum Current 24.0A at 100 127 VAC, 12A / cord
12.0A at 200 240 VAC, 12A / cord
Heat output 2150 BTU/hr
Temperature Operating: 5° C to 35° C (41° F to 95° F) *
Nonoperating: -20° C to 60° C (-4° F to 140° F) *
Optimal: 21° C to 23° C (70° F to 74° F)
Humidity Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 8% to 80% relative humidity, noncondensing
Optimal: 45% to 50% relative humidity, noncondensing
Altitude Operating: Up to 3048m (10000 ft)
Nonoperating: 12000m (40000 ft)
* - derated 2° C for every 1km up to 3km
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL, WEEE and Chinese RoHS
Safety CSA60950-1-03, UL60950-1, IEC60950-1, 1(2001), GB4943-2001 Scheme with all national deviations
Ergonomics N/A
RFI/EMI FCC part-15, EN55022/CISPR22, VCCI, AS/NZS CISPR 22, EN 300 386, EN61000-3-2, EN61000-3-3, JISC61000-3-2, KN22, GB9254, GB17625
Immunity EN55024, EN 300 386, KN24
Regulatory Markings CE, FCC, VCCI, CSA C/US
Dimensions and Weights
Height 8.7 cm (3.43 in)
Width 44 cm (17.33 in)
Depth 65.7 cm (25.87 in)
Weight 22kg (48.50 lbs)
Power Cord 1 - 2, 4m (13 ft) *
Americas, Japan, & Taiwan: NEMA L5-15 125V 15A, NEMA L6-20 250V 20A
All other locations except Japan & Taiwan: IEC 60309 16A 250V, 3PIN with IEC60309 C20
* - 2 power cords required for redundancy
Clearance and Service Access
Front 91.4cm (36 in)
Rear 91.4cm (36 in)
Right none - front to back cooling
Left none - front to back cooling
Top 91.4cm (36 in)
Airflow Front to back - 8.5 cubic meters per minute (300 cfm) in normal operating conditions
Rack Mounting
Sun Rack 1000-38, Sun Rack 1000-42, Sun Rack 900