Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Netra[tm] X4270 Server Hardware Specifications

Processor
Number Two Intel Quad-core
Architecture Type: Quad-Core Intel Xeon L5518 (8MB L3, 5.86 GT/s QPI, 2.13 GHz, 1066 MHz FSB, 60W)
Cache memory 32KB instruction and 32KB data L1 cache per core
256KB unified (data and instruction) L2 cache per core
8MB shared inclusive L3 cache per processor
Main Memory
Capacities DIMM slots per CPU socket: 9
Total DIMM slots (when 2 CPU's are installed): 18
DIMM type: PC3-10600 DDR3-1333 Registered DIMMs
PC3-8500 DDR3-1066 Registered DIMMs
DIMM size: 4GB, 8GB
Maximum capacity: 144 GB (when configured with 8GB DIMMs)
Standard Integrated Interfaces
Network Four 10/100/1000Base-T Ethernet ports
Network Management One 10/100Base-T Ethernet port
Serial Management One TIA/EIA-232-F asynchronous RJ45 port
SAS Four-channel SAS Interface (with SFF-8088 connector), internal access only
USB (2.0)
Rear: 2
Video
One VGA Video port (HD-15)
Alarms
Four fail-safe  DB-15 dry contact  (critical, major, minor and user)
Expansion Bus Two PCI-Express full-height, full length slots (x8 electrical, x16 mechanical)
Four x8 PCI-Express MD2 low profile slots
Note: PCI-Express MD2 slot 3 is reserved for the internal SAS host bus adapter
Internal Mass Storage
Option 1
DVD-R/W, up to two 300GB 2.5in 10K RPM SAS disks, maximum capacity 600GB
Option 2
No DVD-R/W, Up to four 300GB 2.5in 10K RPM SAS disks, maximum capacity 1.2TB
DVD-ROM One Slimline DVD/RW
Power Supplies
Two 660W (1+1) hot-swappable DC
Note: To ensure redundant operation of the power supplies, the two power inputs should be connected to separate power sources. 
Nominal input voltages
-48VDC or -60VDC
Operating input voltage range
-48VDC or -75VDC
Max operating input current
15.4 A at -48VDC (740 VA)
Maximum Operating Input Power
740 W
Environment
Temperature Operating: 5° C to 40° C (41° F to 104° F)/Short term: 5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 85% relative humidity noncondensing, max wet bulb.  Short term: 5% to 90% relative humidity noncondensing, but not to exceed 0.024kg water/kg dry air (0.053 lbs. water 2.205 lb. dry air)
Nonoperating: up to 93% relative humidity noncondensing, 40° C (104.4° F) max wet bulb
Altitude Operating: up to 3,000m (9,850 ft.) @40° C (104° F)
Nonoperating: up to 12,000m (40,000 ft.)
Acoustic noise Operating/Idling Acoustic Noise 7.2B (LwAd, 1B=10dB)
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:Y
Safety UL/CSA-60950-1 2nd edition 2007-03-27, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part 1040, CNS`4336, GB4943
Ergonomics EK`-ITB-2000
RFI/EMC EN55022:2006+A1:2007/CISPR22:2005+A1+A2:2006 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB9254 Class A,GB17625.1, EN61000-3-3, EN61000-3-3
Immunity EN55024, IEC 61000-4-2 Electrostatic discharge, IEC 61000-4-3 RF E-field immunity, IEC 61000-4-4 Electrical Fast Transient/Burst, IEC 61000-4-5 Surge, IEC 61000-4-6 RF-Conducted immunity, IEC 61000-4-8 Power frequency magnetic field immunity, IEC 61000-4-11 Voltage dips, short interruptions
Telecommunications
EN 300 386, IEC 60068, Telcordia NEBS Level 3
Regulatory Markings
CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, KCC, UL/cUL, UL/DEMOKO/GS, UL/S-mark, CCC
Seismic
GR-63-CORE requirements for earthquake zone 4
Dimensions and Weight
Height 87.4 mm (3.44 in.) 2 RU
Width 442 mm (17.4 in.) including bezel
425.5 mm (16.75 in.) chassis
Depth To connector plane: 500 mm (20 in.)
Max overall: 525 mm (20.67 in.)
Weight Approximate (without PCI cards)
18.7 kg (41.23 lb.)
Service Access Clearance Front: 91 cm (36 in.)
Rear: 91 cm (36 in.)
Rack Mounting
Rack Units
2
Fits into standard 19-inch wide rack. Rack kit included: 19-inch 4-post
Racks Available
  • Sun Rack 900-38
  • Sun Rack 900-36N
  • Sun Rack 1000-38
  • Sun Rack 1000-42
  • Sun Rack II-1042
  • Sun Rack II-1242
  • Third Party ANSI/EIA-310-D-1992 or IEC 60927-compliant racks
    in 19-inch/482.6mm panel-width series
Additional Rack Kits Available
  • 19-inch 2-post
  • 23-inch 2-post
  • 600mm x 600mm and
  • 19-inch 4-post slide adjustable1
  • 19-inch 4-post slide mount kit with cable management arm
1 The slide kit includes hardware that enables mounting to any of the following types of rack rails:
  • 6 mm threaded holes
  • #10-32 threaded holes
  • #10 threaded holes
These must be compliant racks which have mounting depths of 27-30 inches.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.