Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Netra[tm] T5440 Server: Hardware Specifications

Processor
Number Two UltraSPARC T2 Plus, multi-core, multi-thread processors
Architecture SPARC V9 architecture, ECC protected
CPUs 1.2GHz 4-Core (64 × 2 for a total of 128 concurrent threads)
1.2GHz 6-Core (64 × 2 for a total of 128 concurrent threads)
1.2GHz 8-Core (64 × 2 for a total of 128 concurrent threads)
1.4GHz 8-Core (64 × 2 for a total of 128 concurrent threads)
Cache memory 4MB Level 2
Main Memory
Capacities Total DIMM slots: 16 slots on the System board, 16 slots on the (optional) Memory Mezzanine
32 slots total (w/ Memory Mezzanine installed.)
DIMM type: FBDIMM
DIMM size: 2GB or 4GB
Maximum capacity: 128GB (32 × 4GB) maximum, 32GB (16 × 2GB) minimum
Standard Integrated Interfaces
Network 4 × 10/100/1000 Mbps auto-negotiating Ethernet ports
2 × 10 Gbps Ethernet ports via the two XAUI slots
Network Management One dedicated 10/100Base-T RJ-45 port Ethernet port
Serial Management One dedicated 10/100Base-T RJ-45 port
Serial One DB-9 serial port connector
SAS One LSI Logic SAS1068E 8-port, 3.0 Gbit/sec. SAS/SATA Controller
USB Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
PCI Expansion Slots Six PCI Express slots MD2 low profile
  • (four x8 Mechanical/x8 Electrical, two x8 Mechanical/x4 Electrical)
  • Two PCI Express slots (Full Height, Full Length)
  • x16 Mechanical/x8 Electrical
  • Two PCI-X slots 64-bit/133MHz, 3.3V (Full Height, Full Legnth)

    Note:If an XAUI card is installed in the XAUI4 or XAUI5 slots, PCI-E Slots 4 & 5 cannot be used, and Ethernet Ports 0 & 1 on the motherboard will be disabled.
    Alarms Four fail-safe, dry contact alarms (critical, major, minor and user)
    Internal Mass Storage
    Disks Up to twelve 2.5" SAS Disk Drives (146 GB or 300GB, 10K RPM) with add-on SAS Host Bus Adapter (HBA).
    DVD-ROM One slimline slot-loaded DVD-R/W
    Power Supplies
    Four redundant, 658W AC or 660W DC power supplies
    Maximum AC input = 7.56A @ 100 VAC (Full output load 658W assuming min efficiency at full load 87%)
    Maximum DC input = 18.75A @ -40VDC (Full output load 660W assuming min efficiency at full load 88%
    Environment
    AC power 100-240 V AC (50-60 Hz)
    DC Power
    -48 V DC or -60 V DC (nominal)
    -40 V DC or -75 V DC (range)
    Temperature Single, non-rack system:
    Operating: 0° C to 40° C (41° F to 104° F)
    Short Term: -5° C to 55° C (23° F to 131° F)
    Nonoperating: -40° C to 70° C (-40° F to 158° F)
    Humidity Single, non-rack system:
    Operating: 5% to 85% relative humidity non-condensing
    Short Term: 5% to 90%, non-condensing, but not to exceed 0.024 kg water/kg dry air (0.053 lbs. water/2.205 lb. dry air)
    Nonoperating: up to 93% relative humidity noncondensing, 40° C (104° F) max wet bulb
    Altitude Single, non-rack system:
    Operating: up to 3000 m (9,850 ft.) @ 40° C
    Nonoperating: up to 12,000 m (40,000 ft.)
    Acoustic noise Single, non-rack system:
    LwAd (1B=10dB)
         7.2 B (operating)
         7.0 B (idle)
    Regulations
    Meets or exceeds the following requirements:
    RoHS Compliance Level RoHS:Y
    Safety UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all national differences, IEC825-1,2, and CFR21 part 1040
    RFI/EMI FCC CFR 47 Part 15 Class A, EN55022/CISPR22 Class A
    Immunity EN55024/CISPR24, EN61000-3-2, EN61000-3-3
    Telecommunications EN300-386
    NEBS NEBS Level 3 Certified by Telcordia
    Seismic GR-63-CORE requirements for earthquake zone 4
    Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
    EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, Gost-R, BSMI Class A
    Dimensions and Weight
    Height 174.2 mm (6.86 in.)
    Width (including bezel) 445 mm (17.5 in.)
    Depth 530 mm (20.87 in.) maximum to PSU handles
    505 mm (19.88 in.) to the rear I/O
    Weight 33 kg (72.6 lb.) fully configured w/o PCI cards
    Rack Mounting
    Netra T5440 server racks (using either the X4059A, X4061A or X4076A rackmount kits) Racks are as follows:
    • Sun Rack 938
    • Sun Rack 1038
    • Sun Rack 1042

      Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
     Feedback