Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Netra[tm] T5220 Server: Hardware Specifications

Processor
Number One UltraSPARC T2 multicore processor
Architecture SPARC V9 architecture, ECC protected
CPUs 1.2GHz 4-Core
1.2GHz 6-Core
1.2GHz 8-Core
Cache memory 4MB Level 2
Main Memory
Capacities Total DIMM slots: 16
DIMM type: FBDIMM
DIMM size: 1GB, 2GB, or 4GB
Maximum capacity: 64GB (16 × 4GB) maximum, 4GB (4 × 1GB) minimum
Standard Integrated Interfaces
Network 4 × 10/100/1000 Mbps ports
Network Management One dedicated 10/100Base-T RJ-45 port Ethernet port
Serial Management One dedicated RJ-45 port
Serial One DB-9 connector
Alarm Four programmable dry contact alarms (critical, major, minor, and user)
USB Rear: 2 USB 2.0 Ports
PCI Expansion Slots 6 slots:
1 PCI-X full height, full length, 133MHz slot
1 PCI-X full height, half length, 133MHz slot
1 PCI-Express full height, full length x8 electrical/x16 physical slot
1 PCI-Express low profile x8 electrical/x8 physical slot
2 PCI-Express/XAUI low profile x4 electrical/x8 physical slots
Internal Mass Storage
Disks Up to 4 300GB SAS 2.5 inch form factor disk drives
DVD-ROM 1 slimline DVD-Writer/CD-Writer
Power Supplies
Two hot-swappable power supplies(AC/DC) providing N + 1 redundancy
Environment
Input Voltage DC: -48 VDC or -60 VDC nominal
AC: 100-240 V AC, 50-60 Hz
Input Current - Total DC: 19 A maximum total for all inputs at -48 VDC
AC: 6 A maximum total for all inputs at 100-120 VAC
Output Power 660 Watts maximum, using one power supply
Heat Output 1365 BTU/hr (1440 KJ/hr)
Temperature

Operating: 5° C to 40° C (41° F to 104° F)
Short Term: -5° C to 55° C (23° F to 131° F)

Humidity Operating: 10% to 90% relative humidity noncondensing, short term, -5°C to 55°C (80.6° F) wet bulb
Short Term: 5% to 90%, non-condensing, but not to exceed 0.024 kg water/kg dry air (0.053 lbs. water/2.205 lb. dry air)
Nonoperating: 93% relative humidity noncondensing, 37.7° C (100.4° F) wet bulb
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:Y
NEBS Level 3 Compliant
Safety UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1,2 CFR21 part 1040, CNS14336, GB4943
Ergonomics EK1-ITB-2000
RFI/EMI EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ3548 Class A CNS 13438 Class A, KSC 5858 Class A, GB9254 Class A, EN61000-3-2, GB17625.1, EN61000-3-3
Immunity EN55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
Telecommunications EN 300-386, IEC 60068
Dimensions and Weight
Height 87.4 mm (3.44 in.)
Width 442 mm (17.4 in.)
Depth 525 mm (20.67 in.)
Weight 17.5 kg (38.5 lb.)
Clearance and Service Access
Front 910 mm (36 in.)
Rear 910 mm (36 in.)
Rack Mounting
TBD

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback