Sun Storage J4500 Array: Hardware Specifications
Disks |
Capacities: |
48 drives per tray. Up to 192 drives in 4 trays.
|
Drive Specifications |
Form factor: 3.5 in., low-profile |
Type, Density, and Speed |
- 1TB 7200 RPM SATA
- 750GB 7200 RPM SATA
- 500GB 7200 RPM SATA *
|
* - Mixing disk drive capacities is not supported. |
Interfaces |
Host interfaces/link speeds |
Four 3 Gb/s SAS total ports per tray
|
Other interfaces |
SAS/SATA drive support |
|
Heat Dissipation
|
1020 Watts (351.5 BTU/hr.) |
AC Power |
500 watts (+5V @ 19A/+12V @ 35A) |
Input Voltage
|
90 -264 VAC |
Input Frequency
|
47-63 Hz |
Output Power
|
1500 W |
Power Consumption
|
110 VA, 1100 W maximum |
Operating Temperature |
0° C to 35° C (32°
F to 95° F) |
Operating Humidity |
20% to 80% humidity, noncondensing
|
Operating Altitude |
0 to 9843 feet |
Shock |
3.0 G @ 11msec, half-sine wave pulse
|
Vibration |
Vertical 0.15G @ 5 Hz to 500 Hz
Horizontal 0.10G @ 5 Hz to 500 Hz
|
|
Height |
175.05 mm (6.89 in) |
Width |
439 mm (17.28 in) |
Depth |
749.9 mm (29.52 in)
|
Weight (maximum) |
77 kg (169.4 lb)
|
|
Note: Meets or exceeds the following
requirements. |
Safety and Emissions |
FCC Class A, ICES-003, CE, VCCI, CCC, BSMI CNS13438, C-Tick,
GOST R2, MIC, Part 15 47 CFR, EN 55022, EN300-396, CISPR 22,
UL/CUL, UL60950-1, TUV, EN60950-1, IEC60950-1, CB, cULus, GOST R, S-Mark
|
|
Sun 72-Inch StorEdge Expansion Cabinet, Sun Rack 900/1000 Cabinet, Sun Fire Expansion Cabinet |
Availability, Reliability, and Serviceability
|
No single point of failure due to redundant controllers
Non-disruptive firmware upgrades
Non-disruptive component (major CRU) replacement
Non-disruptive hot-swappable controllers
Non-disruptive hot-swappable disk drives
Dual hot-swappable, redundant, and load-sharing power supplies |
|
|