Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] D1000 Array : Archived FINs and FCOs

Implementation (Impl.):
M = Mandatory (Fully Pro-Active)

C = Controlled Pro-Active (per Sun Geo Plan)

U = Upon Failure
R = Reactive (As Required)

FAB Implementation Synopsis Last Modified Date
A0222-1 U Seagate Cheetah 4 FCAL and SCSI disk drives may experience higher than expected failure rate. Jan 04 2006
A0182-2 U Systems with 18.2GB and 36GB IBM disk drives may experience higher than expected failure rate. Feb 07 2005
A0163-1 C Systems with large quantities of UDWIS/SBus Host Adapters installed may not come up after reboot due to miscommunication between the SCSI host and the target. Mar 31 2000
A0162-1 C StorEdge A1000 and D1000 (Dilbert) power supplies fail with amber LED. Mar 09 2000
I0670-1 R D1000 ESM board replacement procedure on A3x00/A3500FC 2001-06-15
I0579-1 C Systems with Ultra DWIS/SBus Host Adapter slow to a halt under heavy IO loads and the Console displays "SCSI transport failed" error messages. 2000-06-08
I0547-1 C Intermittently, SCSI devices connected to a UDWIS card may 2000-01-21
I0447-1 C SEVM2.5 patch 105463-05 may cause storage devices to disappear from system. 2004-01-07
I0441-1 C New disk firmware rev. 7063 for ISP boot failures on D1000(s) with Seagate ST39173WC 9Gb disks. 2004-01-07
I0439-1 R A1000/D1000 Rackmount Kits may not contain enough screws to complete the installation. 1998-11-05
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback