Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
System Notes:
Hitachi part numbers are listed in the description column, with brackets.

Array Controller
Option # Manufacturing
Part #
Description Previous
Part #
n/a 370-7107 [F] Serial 8-Port Channel Assembly; WP512-A × 1 and SH343-A × 4, [5524263-A] n/a
n/a 370-7108 [F] MF Fibre 4-Port Channel Assembly ; (Short 1-2Gbps) WP515-A × 1 and SH343-A × 4, [5524259-A] n/a
n/a 370-7109 [F] MF Fibre 4-Port Channel Assembly; (Long 1-2Gbps) WP515-B × 1 and SH343-A × 4, [5524260-A] n/a
n/a 370-7112 [F] NAS 4-Port Channel Assembly; WP517-A × 1 and SH343-A × 1, [5524264-A] n/a
n/a 370-7114 [F] Fibre 8-Port Channel Assembly;(Short 1-2Gbps) WP513-A × 1 and SH343-A × 2, [5524257-A] n/a
n/a 370-7115 [F] Fibre 16-Port Channel Assembly; (Short 1-2Gbps) WP513-B × 1 and SH343-A × 4, [5524258-A] n/a
n/a 371-0239 [F] Printed Circuit Board FSW (SH404-A PK-Assy), (DKC515I-B2R), [5527983-C], L n/a
n/a 371-0246 [F] Mix Adapter (Fibre 8-port & Disk Adapter 4-port) WP525-Bx1 & SH343-Bx4, (DKC515I-MIX2R), [5527991-C], L n/a
n/a 371-0286 [F] Serial 8-port Channel Assembly WP512-B x1 & SH343-B x4, (DKC510I-16SR), [5524263-C], L n/a
n/a 371-0287 [F] MF Fibre 4-port Channel Assembly (Long 1-2Gbps) WP515-D x1 & SH343-B x4, (DKC-F510I-8MLR), [5524260-C], L n/a
n/a 371-0288 [F] MF Fibre 4-port Channel Assembly (Short 1-2Gbps) WP515-C x1 & SH343-B x4, (DKC-F510I-8MSR), [5524259-C], L n/a
n/a 371-0317 [F] NAS 4-port Channel Assembly WP517-C x1 & SH343-B x1, (DKC-510I-8NSR), [5524264-C], L n/a
n/a 371-0318 [F] Fibre 8-port Channel Assembly (Short 1-2Gbps) WP513-C x1 & SH343-B x2, (DKC-F510I-16HSR), [5524257-C], L n/a
n/a 371-0319 [F] Fibre 16-port Channel Assembly (Short 1-2Gbps) WP513-D x1 & SH343-B x4, (DKC-F510I-32HSR), [5524258-C], L n/a
n/a 371-0320 [F] Fibre 16-port Channel Assembly (Short 1-4Gbps), [5524268-C], L n/a
n/a 371-1892 [F] Fibre 16-port Channel Assembly (Short 1-4Gbps), (DKC-F510I-32FS2R), [5524228-C], L n/a
n/a 371-1893 [F] Fibre 8-Port Channel Assembly; (Short 1-4Gbps) DKC-F510I-16FS2R, [5524222-C], L n/a
n/a 371-2460 [F] Mix Adapter (Fibre 8-port & Disk Adapter 4-port) WP526-A×1 & SH343-B×4, (DKCF515I-MIX4R), [5527992-C], n/a
Cables
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-0248 [F] Cable Device Interface (connects DKC and DKU-UC0R) 1-A2 (MIX) to RK0-0-A1 (FSW), (DKC515I-UC0R), [5529786-B], L n/a
n/a 371-0249 [F] Cable Device Interface (connects DKC and DKU-UC0R) 1-A3 (MIX) to RK0-2-A1 (FSW), (DKC515I-UC0R), [5529786-C], L n/a
n/a 371-0250 [F] Cable Device Interface (connects DKC and DKU-UC0R) 1-A4 (MIX) to RK0-2-B1 (FSW), (DKC515I-UC0R), [5529786-D], L n/a
n/a 371-0251 [F] Cable Device Interface (connects DKC and DKU-UC0R) 1-A5 (MIX) to RK0-0-A3 (FSW), (DKC515I-UC0R), [5529786-E], L n/a
n/a 371-0252 [F] Cable Device Interface (connects DKC and DKU-UC0R) 1-A6 (MIX) to RK0-2-A3 (FSW), (DKC515I-UC0R), [5529786-F], L n/a
n/a 371-0253 [F] Cable Device Interface (connects DKC and DKU-UC0R) 2-F1 (MIX) to RK0-1-B1 (FSW), (DKC515I-UC0R), [5529786-G], L n/a
n/a 371-0254 [F] Cable Device Interface (connects DKC and DKU-UC0R) 2-F2 (MIX) to RK0-1-A1 (FSW), (DKC515I-UC0R), [5529786-H], L n/a
n/a 371-0255 [F] Cable Device Interface (connects DKC and DKU-UC0R) 2-F3 (MIX) to RK0-3-A1 (FSW), (DKC515I-UC0R), [5529786-J], L n/a
n/a 371-0256 [F] Cable Device Interface (connects DKC and DKU-UC0R) 2-F4 (MIX) to RK0-3-B1 (FSW), (DKC515I-UC0R), [5529786-K], L n/a
n/a 371-0257 [F] Cable Device Interface (connects DKC and DKU-UC0R) 2-F5 (MIX) to RK0-1-A3 (FSW), (DKC515I-UC0R), [5529786-L], L n/a
n/a 371-0258 [F] Cable Device Interface (connects DKC and DKU-UC0R) 2-F6 (MIX) to RK0-3-A3 (FSW), (DKC515I-UC0R), [5529786-M], L n/a
n/a 371-0259 [F] Cable (DKC to DKU-UC1R) RK0-0-B2 (FSW) to RK1-0-B1 (FSW) AND/ RK2-0-B2 (FSW) to RK3-0-B1 (FSW), (DKC515I-UC1R), [5529787-A], L n/a
n/a 371-0261 [F] Cable (DKC to DKU-UC1R) RK0-2-A2 (FSW) to RK1-2-A1 (FSW) AND/ RK2-2-A2 (FSW) to RK3-2-A1 (FSW), (DKC515I-UC1R), [5529787-C], L n/a
n/a 371-0262 [F] Cable (DKC to DKU-UC1R) RK0-2-B2 (FSW) to RK1-2-B1 (FSW) AND/ RK2-2-B2 (FSW) to RK3-2-B1 (FSW), (DKC515I-UC1R), [5529787-D], L n/a
n/a 371-0263 [F] Cable (DKC to DKU-UC1R) RK0-0-A4 (FSW) to RK1-0-A3 (FSW) AND/ RK2-0-A4 (FSW) to RK3-0-A3 (FSW), (DKC515I-UC1R), [5529787-E], L n/a
n/a 371-0264 [F] Cable (DKC to DKU-UC1R) RK0-2-A4 (FSW) to RK1-2-A3 (FSW) AND/ RK2-2-A4 (FSW) to RK3-2-A3 (FSW), (DKC515I-UC1R), [5529787-F], L n/a
n/a 371-0265 [F] Cable (DKC to DKU-UC1R) RK0-1-B2 (FSW) to RK1-1-B1 (FSW) AND/ RK2-1-B2 (FSW) to RK3-1-B1 (FSW), (DKC515I-UC1R), [5529787-G], L n/a
n/a 371-0266 [F] Cable (DKC to DKU-UC1R) RK0-1-A2 (FSW) to RK1-1-A1 (FSW) AND/ RK2-1-A2 (FSW) to RK3-1-A1 (FSW), (DKC515I-UC1R), [5529787-H], L n/a
n/a 371-0267 [F] Cable (DKC to DKU-UC1R) RK0-3-A2 (FSW) to RK1-3-A1 (FSW) AND/ RK2-3-A2 (FSW) to RK3-3-A1 (FSW), (DKC515I-UC1R), [5529787-J], L n/a
n/a 371-0268 [F] Cable (DKC to DKU-UC1R) RK0-3-B2 (FSW) to RK1-3-B1 (FSW) AND/ RK2-3-B2 (FSW) to RK3-3-B1 (FSW), (DKC515I-UC1R), [5529787-K], L n/a
n/a 371-0269 [F] Cable (DKC to DKU-UC1R) RK0-1-A4 (FSW) to RK1-1-A3 (FSW) AND/ RK2-1-A4 (FSW) to RK3-1-A3 (FSW), (DKC515I-UC1R), [5529787-L], L n/a
n/a 371-0270 [F] Cable (DKC to DKU-UC1R) RK0-3-A4 (FSW) to RK1-3-A3 (FSW) AND/ RK2-3-A4 (FSW) to RK3-3-A3 (FSW), (DKC515I-UC1R), [5529787-M], L n/a
n/a 371-0271 [F] Cable Device Interface (connects DKC and DKU-EXC0R) RK1-0-B2 (FSW) to RK2-0-B1 (FSW), (DKC515I-EXC0R), [5529790-A], L n/a
n/a 371-0272 [F] Cable Device Interface (connects DKC and DKU-EXC0R) RK1-0-A2 (FSW) to RK2-0-A1 (FSW), (DKC515I-EXC0R), [5529790-B], L n/a
n/a 371-0273 [F] Cable Device Interface (connects DKC and DKU-EXC0R) RK1-2-A2 (FSW) to RK2-2-A1 (FSW), (DKC515I-EXC0R), [5529790-C], L n/a
n/a 371-0274 [F] Cable Device Interface (connects DKC and DKU-EXC0R) RK1-2-B2 (FSW) to RK2-2-B1 (FSW), (DKC515I-EXC0R), [5529790-D], L n/a
n/a 371-0276 [F] Cable Device Interface (connects DKC and DKU-EXC0R) RK1-2-A4 (FSW) to RK2-2-A3 (FSW), (DKC515I-EXC0R), [5529790-F], L n/a
n/a 371-0277 [F] Cable Device Interface (connects DKC and DKU-EXC0R) RK1-1-B2 (FSW) to RK2-1-B1 (FSW), (DKC515I-EXC0R), [5529790-G], L n/a
n/a 371-0278 [F] Cable Device Interface (connects DKC and DKU-EXC0R) RK1-1-A2 (FSW) to RK2-1-A1 (FSW), (DKC515I-EXC0R), [5529790-H], L n/a
n/a 371-0279 [F] Cable Device Interface (connects DKC and DKU-EXC0R) RK1-3-A2 (FSW) to RK2-3-A1 (FSW), (DKC515I-EXC0R), [5529790-J], L n/a
n/a 371-0280 [F] Cable Device Interface (connects DKC and DKU-EXC0R) RK1-3-B2 (FSW) to RK2-3-B1 (FSW), (DKC515I-EXC0R), [5529790-K], L n/a
n/a 371-0281 [F] Cable Device Interface (connects DKC and DKU-EXC0R) RK1-1-A4 (FSW) to RK2-1-A3 (FSW), (DKC515I-EXC0R), [5529790-L], L n/a
n/a 371-0282 [F] Cable Device Interface (connects DKC and DKU-EXC0R) RK1-3-A4 (FSW) to RK2-3-A3 (FSW), (DKC515I-EXC0R), [5529790-M], L n/a
Communication
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-0283 [F] Modem Card (ME5614CG3), [5524212-C], L n/a
Disks
Option # Manufacturing
Part #
Description Previous
Part #
TJ9DKUF515I-146K1R 371-1532 146GB FC Disk Drive/15k RPM, L n/a
TJ9DKUF515I-146KSR 371-1531 146GB FC Disk Drive/15kmin, L n/a
TJ9DKUF515I-300K1R 371-3713 1 HDD Spare Canister (300GB/15K RPM) (Multi Vendor)[5524276-E] n/a
TJ9DKUF515I-300KSR 371-3712 1 HDD Spare Canister (300GB/15K RPM) (Multi Vendor)[5524276-D], n/a
TV9DKUF515I-400J1R 371-4215 1 HDD Spare Canister (400GB - 10K RPM FC), n/a
TV9DKUF515I-400JSR [S] 371-4211 1 HDD Canister (400GB - 10K RPM FC), n/a
n/a 370-7127 [F] 72GB Disk Drive/15kmin-1; (DKS2C-K72FC), [5524271-A] n/a
n/a 370-7128 [F] 146GB Disk Drive/10kmin-1; (DKR2A-J146FC), [5524269-A] n/a
n/a 371-0323 [F] 72GB Disk Drive/15kmin-1 (DKS2D-K72FC), [5524271-D], L n/a
n/a 371-0324 [F] 146GB Disk Drive/10kmin-1 (DKR2D-J146FC/DKR2F-J146FC), (DKU-505I-146JSR), [5524269-D], L n/a
n/a 371-0325 [F] 146GB Disk Drive/15kmin-1;(DKS2D-K146FC), [5524272-D], L n/a
n/a 371-0326 [F] 300GB Disk Drive/10kmin-1 (DKS2D-J300FC), [5524270-D], L n/a
n/a 371-0341 [F] 146GB Disk Drive/15kmin-1; HDU500-146K1FC (DKS2D-K146FC), [5524272-A] n/a
n/a 371-3638 [F] 300GB Disk drive/15kmin-1 (DKS2E-K300FC), [5524276-D|E], n/a
n/a 371-4207 [F] 400GB Disk drive/10kmin-1 (DKS2E-J400FC), [5524277-E], n/a
n/a 371-4489 [F] 146GB Disk Drive/10kmin-1 (DKR2E-J146FC/DKR2F-J146FC),[5524269-E] 371-0324 [F]
n/a 371-4490 [F] 300GB Disk Drive/10kmin-1 (DKS2E-J300FC),[5524270-E] 371-0326 [F]
n/a 371-4491 [F] 72GB Disk Drive/15kmin-1 (DKS2E-K72FC),[5524271-E] 371-0323 [F]
n/a 371-4492 [F] 146GB Disk Drive/15kmin-1 (DKS2E-K146FC),[5524272-E] 371-0325 [F]
n/a 371-4493 [F] 146GB Disk Drive/10kmin-1 (DKS2D-J146FC),[5524269-F] 371-0324 [F]
n/a 371-4494 [F] 300GB Disk Drive/10kmin-1 (DKR2F-J300FC),[5524270-F] 371-0326 [F]
n/a 371-4495 [F] 72GB Disk Drive/15kmin-1 (DKS2F-K72FC),[5524271-F] 371-0323 [F]
n/a 371-4496 [F] 146GB Disk Drive/15kmin-1 (DKR2F-K146FC/DKR2G-K146FC),[5524272-F] 371-0325 [F]
n/a 371-0691 [F] [S] 146GB Disk Drive/15kmin-1; HDU500-146K1FC (DKS2D-K146FC), [5524272-D] n/a
Ethernet
Option # Manufacturing
Part #
Description Previous
Part #
TJ9DKCF515I-8ISR 371-2279 iSCSI 8-port Channel Adapter (1.25Gbps Gigabit Ether Ports, Short-wave), L n/a
Fan
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-0241 [F] Fan Assembly for DKC with TH Assembly, (DKC515I-5/5R), [5527963-C], L n/a
n/a 371-0242 [F] Fan Assembly for DKC, (DKC515I-5/5R), [5527964-C], L n/a
Fibre Channel
Option # Manufacturing
Part #
Description Previous
Part #
TJ9DKCF515I-16MFLR 371-2520 4Gb/sec FICON 16 Port Long Wavelength (single mode) Channel Adapter, n/a
TJ9DKCF515I-16MFSR 371-2519 4Gb/sec FICON 16 Port Short Wavelength (multi-mode) Channel Adapter, n/a
TJ9DKCF510I-1FLR [S] 371-2068 1-4Gbps Fibre Channel Transceiver Long Wave SFP, L n/a
TJ9DKCF510I-1FSR [S] 371-2067 1-4Gbps Fibre Channel Transceiver Short Wave SFP, L n/a
TJ9DKCF515I-MIX4R [S] 371-2521 4Gb/sec Mixed Fibre Channel Adapter Board, Short Wave SFP, n/a
n/a 370-7116 [F] 2Gbps Fibre Channel Transceiver Long Wave SFP, [5524230-A] n/a
n/a 370-7117 [F] 2Gbps Fibre Channel Transceiver Short Wave SFP, [5524229-A] n/a
n/a 371-0321 [F] Fibre SFP Transceiver for Long Wavelength, (DKC-F510I-1HLR), [5524230-C], L n/a
n/a 371-0322 [F] Fibre SFP Transceiver for Short Wavelength, (DKC-F510I-1HSR), [5524229-C], L n/a
n/a 371-1890 [F] 1-4Gbps Fibre Channel Transceiver Short Wave SFP, (DKC-F510I-1FSR), [5524231-C], L n/a
n/a 371-1891 [F] 1-4Gbps Fibre Channel Transceiver Long Wave SFP, (DKC-F510I-1FLR), [5524234-C], L n/a
Memory
Option # Manufacturing
Part #
Description Previous
Part #
DKC-F510I-C8GR 8GB Cache Memory Module Option
371-1557 [F] PCB CM 2GB DIMM (SH342-D PK-ASSY) [5524242-C] n/a
TJ9DKCF515I-C8GR 4 [S] 8GB Cache Memory Module Option,
371-1557 [F] PCB CM 2GB DIMM (SH342-D PK-ASSY) [5524242-C] n/a
TJ9DKCF515I-S2GR 5 [S] 2GB Shared Memory Module Option
371-1558 [F] PCB SM DIMM (SH341-D PK-ASSY) [5524237-C] n/a
n/a 370-7104 [F] Printed Circuit Board SM DIMM; SH341-A, [5524235-A] PK-Assy n/a
n/a 370-7105 [F] Printed Circuit Board CM 1GB DIMM; SH342-A, [5524236-A] PK-Assy n/a
n/a 371-0245 [F] Printed Circuit Board BASE (WP535-A PK-Assy), (DKC515I-5/5R), [5527989-C], L n/a
n/a 371-0284 [F] Printed Circuit Board SM DIMM (SH341-C PK-Assy), (DKC510I-S1GR), [5524235-C], L n/a
n/a 371-0285 [F] Printed Circuit Board CM 1GB DIMM (SH342-C PK-Assy), (DKC510I-C4GR), [5524236-C], L n/a
4 Maximum number of installable options is:
* 8 sets (Cache capacity: 32GB) when the DKC-F510I-CX1GR is not installed, or
* 8 sets (Cache capacity: 64GB) when the DKC-F510I-CX1GR is installed.
5 Required number of shared memory is determined based on the cache capacity of the subsystem, disk capacity (number of LDEVs), and program products to be installed.
Power
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-0236 [F] Battery Box for DKC515I, (DKC515I-LGABR), [5527959-C], L n/a
n/a 371-0237 [F] AC/DC Box - 960-C, (DKC515I-5/5R), [5527960-C], L n/a
n/a 371-0238 [F] AC/DC Box - 961-C, (DKC515I-B2R), [5527961-C], L n/a
Rack
Option # Manufacturing
Part #
Description Previous
Part #
TJ97846443R [S] 371-1835 Sun StorEdge 19 inch Global Rack (US and the Americas), L n/a
TJ97846444R [S] 371-1836 Sun StorEdge 19 inch Global Rack (APAC), L n/a
TJ97846445R [S] 371-1837 Sun StorEdge 19 inch Global Rack (EMEA), L n/a
Switch/Hub
Option # Manufacturing
Part #
Description Previous
Part #
TJ9DKCF510I-16FS2R [S] 371-2071 FC 16-Port Front End Director (Short Wavelength 1-4Gbps), L n/a
System Service Processor
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-0240 [F] SVP for DKC515I, (DKC515I-5/5R), [5527951-C], L n/a
n/a 371-0244 [F] Printed Circuit Board SSVP (SH407-A PK-Assy), (DKC515I-5/5R), [5527978-C], L n/a