Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Storage 7410 (SAS 2.0) - Full Components List

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
System Notes:
This product is based on the Sun Fire X4440 server and the Sun Disk Shelf 24x3.5" SAS-2, but uses specialized components. Only use parts listed in the Sun Storage 7410 (SAS 2.0) Full Components List to service this product.

Array Controller
Option # Manufacturing
Part #
Description Previous
Part #
n/a 542-0194 [C] 6Gbps SAS-2 Interface Module (SIM), n/a
n/a 7014947 6Gbps SAS-2 Interface Module (SIM), {PKG} n/a
  • 7014946 [C]
  • 6Gbps SAS-2 Interface Module (SIM),
542-0194 [C]
NOTE: Don't mix SIM card firmware 3520 with SIM card firmware 3524. See FAB 1307357.1 for details.
NOTE: 6Gbps SAS-2 Interface Module (SIM) PN#542-0194 and PN#7014947 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
Batteries
Option # Manufacturing
Part #
Description Previous
Part #
n/a 150-4277 [C] 3V Lithium coin battery, n/a
CPU Module
Option # Manufacturing
Part #
Description Previous
Part #
n/a 310-0128 Opteron Heatsink, n/a
n/a 371-4042 [F] 2.3 GHz CPU, Opteron 2356 Quad Core, B3 Stepping, 75W, n/a
n/a 371-4044 [F] 2.3 GHz CPU, Opteron 8356 Quad Core, B3 Stepping, 75W, n/a
n/a 371-4681 [F] 2.6 GHz CPU, Opteron 2435 6-Core, D0 Stepping, 75W, n/a
n/a 371-4684 [F] 2.6 GHz CPU, Opteron 8435 6-Core, D0 Stepping; 75W, n/a
n/a 540-7597 [F] CPU/Memory Mezzanine Assembly, L n/a
  • 330-4622
  • Air Duct,
n/a
  • 501-7723
  • Mezzanine Card, L
n/a
  • 541-2769
  • Tray,
n/a
n/a 540-7602 [F] HyperTransport Bridge Card & Risers for Quad Core CPU, n/a
  • 270-7916 [F]
  • Hyper-Transport Bridge Risers (×2)
n/a
  • 501-7915
  • Hyper-Transport Bridge Card,
n/a
n/a 540-7953 [F] CPU/Memory Mezzanine Assembly, L 540-7597 [F]
  • 330-4622
  • Air Duct,
n/a
  • 511-1395
  • Mezzanine Card, L
n/a
  • 541-2769
  • Tray,
n/a
n/a 541-2906 [C] HyperTransport Riser, n/a
Cables
Option # Manufacturing
Part #
Description Previous
Part #
n/a 530-3771 RJ-45 Ethernet Cable (1m), n/a
n/a 530-3886 [F] 4X Mini SAS Cable, SFF-8088 to SFF-8088, 0.5M, L n/a
Communication
Option # Manufacturing
Part #
Description Previous
Part #
X4237A-N [S] 375-3606 [C] Sun Dual Port 40Gb/sec 4x Infiniband QDR Host Channel Adapter PCI Express n/a
n/a 371-3024 [F] Cluster Heartbeat Card, n/a
Disk Backplane
Option # Manufacturing
Part #
Description Previous
Part #
n/a 501-7730 [F] 8-Slot Disk Backplane, PATA DVD, n/a
n/a 542-0355 [F] Backplane Retainer Clip Kit n/a
  • 330-5301
  • Grey 2U Backplane Retainer Clip
n/a
Disks
Option # Manufacturing
Part #
Description Previous
Part #
n/a 350-1574 Disk Shelf SSD Filler Panel n/a
n/a 540-7711 [C] 500GB - 5400 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks:, n/a
  • Hitachi HTE545050KTA300 [HTE5450SASSUN500G]
    (500GB - 5400 RPM - SATA Disk),
n/a
  • Marlin Bracket,
n/a
n/a 541-4242 Disk Shelf HDD Filler Panel, n/a
n/a 542-0184 [C] 500GB - 7200 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks:, n/a
  • Seagate ST9500530NS [ST95000NSSUN500G]
    (500GB - 7200 RPM - SATA Disk)
n/a
  • Marlin Bracket,
n/a
n/a 542-0274 [C] 2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST32000444SS [ST32000SSSUN2.0T] (2TB - 7200 RPM - SAS Disk)
n/a
  • Stingray Mounting Bracket
n/a
n/a 542-0340 [C] 1TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST31000424SS [ST31001SSSUN1.0T] (1TB - 7200 RPM - SAS Disk),
n/a
  • Stingray Mounting Bracket
n/a
n/a 7015705 18GB SAS Solid State Drive Assembly {PKG} F542-0286
  • 18GB SAS Solid State Drive Assembly
542-0286 2 [C]
    • 18GB SAS Solid State Drive,
n/a
    • Stingray Mounting Bracket
n/a
n/a F542-0286 18GB SAS Solid State Drive Assembly n/a
  • 18GB SAS Solid State Drive Assembly
n/a
    • 18GB SAS Solid State Drive,
n/a
    • Stingray Mounting Bracket
n/a
2 SSD firmware needs to be at version 9002 or later, See FAB 1307373.1 for details.
3 SSD firmware needs to be at version 9002 or later, See FAB 1307373.1 for details.
4 SSD firmware needs to be at version 9002 or later, See FAB 1307373.1 for details.
NOTE: Disk Drive Assembly PN#542-0274 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
NOTE: Disk Drive Assembly PN#542-0340 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
NOTE: PN#350-1574 and PN#541-4242 are used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
NOTE: Disk Drive Assembly PN#7015704 / PN#542-0286 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
Ethernet
Option # Manufacturing
Part #
Description Previous
Part #
X1027A-Z-N Price 501-7283 [C] PCI Express Dual 10-Gigabit Ethernet Fiber, n/a
X4446A-Z-N Price 375-3481 [C] PCI Express Quad Gigabit Ethernet UTP, n/a
X5558A Price 375-3301 [C] 10Gb/sec XFP Optical Transceiver Short Range (SR), L n/a
X5560A-Z-N Price 375-3495 [C] 10Gb/sec XFP Optical Transceiver Long Range (LR), n/a
X7280A-2-N Price 371-0905 [C] PCI Express Dual Gigabit Ethernet UTP, n/a
X7281A-2-N Price 371-0904 [C] PCI Express Dual Gigabit Ethernet MMF, n/a
Fan
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2211 [F] Fan Power Board, n/a
  • 330-4463
  • Top Bracket,
n/a
  • 330-4464
  • Bottom Bracket,
n/a
  • 501-7695
  • Fan Board,
n/a
n/a 541-2940 [C] CPU Dual Fan Assembly w/ Metal Fingerguards, n/a
  • 310-0119
  • Delta Fan, 60×38mm, 2U,
n/a
Fibre Channel
Option # Manufacturing
Part #
Description Previous
Part #
SG-XPCIE2FC-QF4-N Price 375-3356 [C] 4Gigabit/Sec PCI Express Dual FC Host Adapter, n/a
SG-XPCIE2FC-QF8-Z Price 371-4325 [C] 8Gigabit/Sec PCI Express Dual FC Host Adapter, n/a
I/O
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2109 [C] x8/x8 XAUI Riser Card Assembly, n/a
  • 341-4139
  • PCI Filler Panel,
n/a
  • 501-7719
  • x8/x8 XAUI Riser Card,
n/a
  • 541-2736
  • Riser Bracket,
n/a
n/a 541-2299 [C] x16/x4 Riser, n/a
Memory
Option # Manufacturing
Part #
Description Previous
Part #
n/a 540-7599 [C] 4GB (2 × 2GB) Memory FRU, n/a
  • 2GB Registered ECC DDR2-667 DIMM,
n/a
n/a 540-7600 [C] 8GB (2 × 4GB) Memory FRU, n/a
  • 4GB Registered ECC DDR2-667 DIMM,
n/a
Power
Option # Manufacturing
Part #
Description Previous
Part #
n/a 300-1897 [C] 1050 Watt Power Supply, Type A217, n/a
n/a 300-2235 [C] 1200W Power Supply, Type A249, n/a
n/a 300-2318 [C] 764W AC Input Power Supply and Fan Assembly, 300-2276 [C]
n/a 541-2073 [F] Power Distribution Board/Bus Bar Assembly, n/a
  • 341-3166
  • Bus Bar Left,
n/a
  • 341-3167
  • Bus Bar Right,
n/a
  • Horizontal Power Distribution Board,
n/a
  • Vertical Power Distribution Board,
n/a
NOTE: 764W AC Input Power Supply and Fan Assembly PN#300-2276 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
Rack
Option # Manufacturing
Part #
Description Previous
Part #
DS2X-4URK-19U Price 350-1531 Rackmount Kit, n/a
  • n/a
  • Left Mounting Rail
n/a
  • n/a
  • Right Mounting Rail
n/a
n/a 371-2740 [C] Snap-In Slide Rail Rackmount Kit, 730mm, n/a
n/a 371-2741 [C] Screw-Mount Slide Rail Rackmount Kit, 730mm, n/a
n/a 371-2742 [C] Cable Management Arm, n/a
NOTE: Rackmount Kit DS2X-4URK-19U/350-1531 is used for rack mounting the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
Removable Media
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2732 [C] USB Assembly, n/a
  • 330-4418
  • DVD Interconnect Holder,
n/a
  • 341-4072
  • DVD Filler Panel,
n/a
  • USB Board,
n/a
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
SG-XPCIESAS-GEN2-Z Price 375-3609 [C] 8-Port 6Gbps SAS-2 RAID HBA, n/a
System Board
Option # Manufacturing
Part #
Description Previous
Part #
n/a 341-4139 PCI Filler Panel, n/a
n/a 540-7952 5 Motherboard, L n/a
  • 3V Lithium coin battery,
n/a
5 The motherboard is not a FRU. Contact Sun Hardware Support if this part is suspected to be faulty.

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

No Artwork Currently Available

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
NS 530-3927 [F] PDB to System Board Ribbon Cable,
NS 540-7980 [C] Disk Shelf Chassis Assembly/FRU,
NS
  • 330-5203
  • Front Left End Cap,
NS
  • 330-5204
  • Front Right End Cap,
NS
  • 375-3659
  • Centerplane Assembly,
NS 541-2213 [F] Connector Board Assembly, PATA DVD,
NS
  • 341-3097
  • Bracket,
NS
  • 501-7720
  • Connector Board (Paddle Card), PATA DVD,
NS
  • 530-3510
  • Magnetic Interlock Switch,
NS F540-7610 [F] SAS/SATA Cable Kit,
NS
  • 530-3892
  • 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm,
NS
  • 530-3894
  • 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 560mm,
NS
  • 530-3895
  • 4x Mini SAS Cable, SFF-8087 to SFF-8087, 530mm,
NOTE: PN#540-7980 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.