Sun Storage 7410 (SAS 2.0) - Full Components List
|
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
|
|
System Notes: |
This product is based on the Sun Fire X4440 server and the Sun Disk Shelf 24x3.5" SAS-2, but uses specialized components. Only use parts listed in the
Sun Storage 7410 (SAS 2.0) Full Components List to service this product.
|
|
Array Controller
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
542-0194
[C]
|
6Gbps SAS-2 Interface Module (SIM), |
n/a |
n/a |
7014947 |
6Gbps SAS-2 Interface Module (SIM), {PKG} |
n/a |
|
- 6Gbps SAS-2 Interface Module (SIM),
|
542-0194
[C]
|
NOTE: Don't mix SIM card firmware 3520 with SIM card firmware 3524. See FAB 1307357.1 for details.
NOTE: 6Gbps SAS-2 Interface Module (SIM) PN#542-0194 and PN#7014947 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
|
Batteries
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
150-4277
[C]
|
3V Lithium coin battery, |
n/a |
CPU Module
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
310-0128 |
Opteron Heatsink, |
n/a |
n/a |
371-4042
[F]
|
2.3 GHz CPU, Opteron 2356 Quad Core, B3 Stepping, 75W,
|
n/a |
n/a |
371-4044
[F]
|
2.3 GHz CPU, Opteron 8356 Quad Core, B3 Stepping, 75W, |
n/a |
n/a |
371-4681
[F]
|
2.6 GHz CPU, Opteron 2435 6-Core, D0 Stepping, 75W,
|
n/a |
n/a |
371-4684
[F]
|
2.6 GHz CPU, Opteron 8435 6-Core, D0 Stepping; 75W, |
n/a |
n/a |
540-7597
[F]
|
CPU/Memory Mezzanine Assembly, L |
n/a |
|
|
n/a |
|
|
n/a |
|
|
n/a |
n/a |
540-7602 [F]
|
HyperTransport Bridge Card & Risers for Quad Core CPU, |
n/a |
|
- Hyper-Transport Bridge Risers (×2)
|
n/a |
|
- Hyper-Transport Bridge Card,
|
n/a |
n/a |
540-7953
[F]
|
CPU/Memory Mezzanine Assembly, L
|
540-7597
[F]
|
|
|
n/a |
|
|
n/a |
|
|
n/a |
n/a |
541-2906
[C]
|
HyperTransport Riser, |
n/a |
Cables
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
530-3771 |
RJ-45 Ethernet Cable (1m), |
n/a |
n/a |
530-3886 [F]
|
4X Mini SAS Cable, SFF-8088 to SFF-8088, 0.5M, L |
n/a |
Communication
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
X4237A-N
[S]
|
375-3606
[C]
|
Sun Dual Port 40Gb/sec 4x Infiniband QDR Host Channel Adapter PCI Express |
n/a |
n/a |
371-3024
[F]
|
Cluster Heartbeat Card, |
n/a |
Disk Backplane
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
501-7730
[F]
|
8-Slot Disk Backplane, PATA DVD, |
n/a |
n/a |
542-0355 [F]
|
Backplane Retainer Clip Kit |
n/a |
|
- Grey 2U Backplane Retainer Clip
|
n/a |
Disks
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
350-1574 |
Disk Shelf SSD Filler Panel |
n/a |
n/a |
540-7711 [C]
|
500GB - 5400 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks:, |
n/a |
|
- Hitachi HTE545050KTA300 [HTE5450SASSUN500G]
(500GB - 5400 RPM - SATA Disk),
|
n/a |
|
|
n/a |
n/a |
541-4242 |
Disk Shelf HDD Filler Panel, |
n/a |
n/a |
542-0184 [C]
|
500GB - 7200 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks:, |
n/a |
|
- Seagate ST9500530NS [ST95000NSSUN500G]
(500GB - 7200 RPM - SATA Disk)
|
n/a |
|
|
n/a |
n/a |
542-0274 [C]
|
2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: |
n/a |
|
- Seagate ST32000444SS [ST32000SSSUN2.0T] (2TB - 7200 RPM - SAS Disk)
|
n/a |
|
- Stingray Mounting Bracket
|
n/a |
n/a |
542-0340 [C]
|
1TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: |
n/a |
|
- Seagate ST31000424SS [ST31001SSSUN1.0T] (1TB - 7200 RPM - SAS Disk),
|
n/a |
|
- Stingray Mounting Bracket
|
n/a |
n/a |
7015705 |
18GB SAS Solid State Drive Assembly {PKG} |
F542-0286 |
|
- 18GB SAS Solid State Drive Assembly
|
542-0286
2
[C]
|
|
- 18GB SAS Solid State Drive,
|
n/a |
|
- Stingray Mounting Bracket
|
n/a |
n/a |
F542-0286 |
18GB SAS Solid State Drive Assembly |
n/a |
|
- 18GB SAS Solid State Drive Assembly
|
n/a |
|
- 18GB SAS Solid State Drive,
|
n/a |
|
- Stingray Mounting Bracket
|
n/a |
2 SSD firmware needs to be at version 9002 or later, See FAB 1307373.1
for details.
3 SSD firmware needs to be at version 9002 or later, See FAB 1307373.1
for details.
4 SSD firmware needs to be at version 9002 or later, See FAB 1307373.1
for details.
NOTE: Disk Drive Assembly PN#542-0274 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
NOTE: Disk Drive Assembly PN#542-0340 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
NOTE: PN#350-1574 and PN#541-4242 are used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
NOTE: Disk Drive Assembly PN#7015704 / PN#542-0286 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
|
Ethernet
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
X1027A-Z-N Price
|
501-7283
[C]
|
PCI Express Dual 10-Gigabit Ethernet Fiber, |
n/a |
X4446A-Z-N Price
|
375-3481
[C]
|
PCI Express Quad Gigabit Ethernet UTP, |
n/a |
X5558A Price
|
375-3301
[C]
|
10Gb/sec XFP Optical Transceiver Short Range (SR), L |
n/a |
X5560A-Z-N Price
|
375-3495
[C]
|
10Gb/sec XFP Optical Transceiver Long Range (LR), |
n/a |
X7280A-2-N Price
|
371-0905
[C]
|
PCI Express Dual Gigabit Ethernet UTP, |
n/a |
X7281A-2-N Price
|
371-0904
[C]
|
PCI Express Dual Gigabit Ethernet MMF, |
n/a |
Fan
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
541-2211
[F]
|
Fan Power Board, |
n/a |
|
|
n/a |
|
|
n/a |
|
|
n/a |
n/a |
541-2940 [C]
|
CPU Dual Fan Assembly w/ Metal Fingerguards, |
n/a |
|
|
n/a |
Fibre Channel
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SG-XPCIE2FC-QF4-N Price
|
375-3356
[C]
|
4Gigabit/Sec PCI Express Dual FC Host Adapter, |
n/a |
SG-XPCIE2FC-QF8-Z Price
|
371-4325
[C]
|
8Gigabit/Sec PCI Express Dual FC Host Adapter, |
n/a |
I/O
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
541-2109
[C]
|
x8/x8 XAUI Riser Card Assembly, |
n/a |
|
|
n/a |
|
|
n/a |
|
|
n/a |
n/a |
541-2299
[C]
|
x16/x4 Riser, |
n/a |
Memory
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
540-7599 [C]
|
4GB (2 × 2GB) Memory FRU, |
n/a |
|
- 2GB Registered ECC DDR2-667 DIMM,
|
n/a |
n/a |
540-7600 [C]
|
8GB (2 × 4GB) Memory FRU, |
n/a |
|
- 4GB Registered ECC DDR2-667 DIMM,
|
n/a |
Power
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
300-1897
[C]
|
1050 Watt Power Supply, Type A217, |
n/a |
n/a |
300-2235
[C]
|
1200W Power Supply, Type A249, |
n/a |
n/a |
300-2318
[C]
|
764W AC Input Power Supply and Fan Assembly, |
300-2276
[C]
|
n/a |
541-2073
[F]
|
Power Distribution Board/Bus Bar Assembly, |
n/a |
|
|
n/a |
|
|
n/a |
|
- Horizontal Power Distribution Board,
|
n/a |
|
- Vertical Power Distribution Board,
|
n/a |
NOTE: 764W AC Input Power Supply and Fan Assembly PN#300-2276 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
|
Rack
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
DS2X-4URK-19U Price
|
350-1531 |
Rackmount Kit, |
n/a |
|
|
n/a |
|
|
n/a |
n/a |
371-2740 [C]
|
Snap-In Slide Rail Rackmount Kit, 730mm, |
n/a |
n/a |
371-2741 [C]
|
Screw-Mount Slide Rail Rackmount Kit, 730mm, |
n/a |
n/a |
371-2742 [C]
|
Cable Management Arm, |
n/a |
NOTE: Rackmount Kit DS2X-4URK-19U/350-1531 is used for rack mounting the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
|
Removable Media
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
541-2732 [C]
|
USB Assembly, |
n/a |
|
|
n/a |
|
|
n/a |
|
|
n/a |
SCSI
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SG-XPCIESAS-GEN2-Z Price
|
375-3609
[C]
|
8-Port 6Gbps SAS-2 RAID HBA, |
n/a |
System Board
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
341-4139 |
PCI Filler Panel, |
n/a |
n/a |
540-7952 5
|
Motherboard, L |
n/a |
|
|
n/a |
5 The motherboard is not a FRU. Contact Sun Hardware Support if this part is suspected to be faulty.
|
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
|
No Artwork Currently Available
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown
|
Code |
Manufacturing Part# |
Description |
NS |
530-3927 [F]
|
PDB to System Board Ribbon Cable, |
NS |
540-7980 [C]
|
Disk Shelf Chassis Assembly/FRU, |
NS |
|
|
NS |
|
|
NS |
|
|
NS |
541-2213
[F]
|
Connector Board Assembly, PATA DVD, |
NS |
|
|
NS |
|
- Connector Board (Paddle Card), PATA DVD,
|
NS |
|
- Magnetic Interlock Switch,
|
NS |
F540-7610 [F]
|
SAS/SATA Cable Kit, |
NS |
|
- 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm,
|
NS |
|
- 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 560mm,
|
NS |
|
- 4x Mini SAS Cable, SFF-8087 to SFF-8087, 530mm,
|
NOTE: PN#540-7980 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
|
|