Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] 3510 / 3511 FC Array LEDs

Front Panel LEDs

 

Note: The "Reset Pushbutton" is used to mute the audible alarm; this button is not used to reset the power on the array. An audible alarm indicates that either a component in the array has failed or a specific controller event has occurred. Error conditions and controller events are reported by event messages and event logs. Component failures are also indicated by LED activity on the array.

LED Name LED State Status Description
Disk Drive Solid Green Good Driver power up and spin up OK
Blinking Green Good Drive activity
Solid Amber Failed Drive failure
Power (light bulb icon) Solid Green Good Power supply good
Solid Amber Failed One or more output voltages out-of-range
Fan Solid Green Good Fan operating at over 3150 RPM
Solid Amber Faulty/Failed Fan operating at under 3150 RPM
Temperature (thermometer icon) Solid Green Good Under temperature threshold of 55º C
Solid Amber Failed Temperature threshold equal to or over 55º C
Blinking Amber Failed Temperature threshold equal to or over 60º C
Event (caution icon) Solid Green Good Normal operation of RAID controller and I/O Board
Solid Amber Faulty/Failed Failed RAID controller or I/O Board
Blinking Amber Faulty/Failed Indicates that the version of SES firmware or associated hardware PLD code on one controller does not match that on the other controller (firmware version mis-match)

 

3510 Rear Panel LEDs

LED Name State Description
Battery Solid Green Battery charged
Blinking Green Battery charging
Solid Amber Battery failed
Activity Off Not busy, no I/O activity
Blinking Green Busy, I/O activity
Cache Off Clean cache
Blinking Green Dirty cache, indicates if data is in memory and is not written to disk yet
Ethernet Link (active controller) Off Inactive connection
Solid Amber Active link
Ethernet Link (inactive controller) Off Active connection on inactive controller or on active connection
Ethernet Active Flashing Green Busy
RAID Controller Solid Green Good (secondary controller)
Blinking Green Good (primary controller)
Solid Amber Failed RAID controller or I/O module
SFP Link (L) Off Empty or failed FC connection
Solid Green Active good FC connection
SFP Speed (S) Off 1 Gbit
Solid Green 2 Gbit

 

3511 Rear Panel LEDs

LED Name State Description
Battery Solid Green Battery charged
Blinking Green Battery charging
Solid Amber Battery failed
Activity Off Not busy, no I/O activity
Blinking Green Busy, I/O activity
Cache Off Clean cache
Blinking Green Dirty cache, indicates if data is in memory and is not written to disk yet
Ethernet link (active controller) Off Inactive connection
Solid Amber Active link
Ethernet link (inactive controller) Off Active connection on inactive controller or inactive connection
Ethernet active Flashing Green Busy
RAID Controller Solid Green Good (secondary controller
Blinking Green Good (primary controller)
Solid Amber Failed RAID controller or I/O module
SFP link (L) Off Empty or failed FC connection
Solid Green Active good FC connection
SFP link (S) Off 1 Gbit
Solid Green 2 Gbit

 

Power Supply and Fan Module LEDs

LED Name State Description
Power Supply/Fan Solid Green Power supply good and fas are good
Solid Amber 3510: Failed, one or more output voltages out-of-range* or fan speed under 3150 RPM
3511: Failed, one or more output voltages out-of-range* or fan speed under 4000 RPM
* Voltage Thresholds: +5 VDC +/- .25VDC, +12VDC +/- .6 VDC
* Current Thresholds: +5 VDC 35A, +12 VDC 25 A

 

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.