Sun StorEdge[tm] 3510 / 3511 FC Array LEDs
Front Panel LEDs
Note: The "Reset Pushbutton" is used to mute the audible alarm; this button is not
used to reset the power on the array. An audible alarm indicates that either a component in the
array has failed or a specific controller event has occurred. Error conditions and controller
events are reported by event messages and event logs. Component failures are also indicated by
LED activity on the array.
LED Name |
LED State |
Status |
Description |
Disk Drive |
Solid Green |
Good |
Driver power up and spin up OK |
Blinking Green |
Good |
Drive activity |
Solid Amber |
Failed |
Drive failure |
Power (light bulb icon) |
Solid Green |
Good |
Power supply good |
Solid Amber |
Failed |
One or more output voltages out-of-range |
Fan |
Solid Green |
Good |
Fan operating at over 3150 RPM |
Solid Amber |
Faulty/Failed |
Fan operating at under 3150 RPM |
Temperature (thermometer icon) |
Solid Green |
Good |
Under temperature threshold of 55º C |
Solid Amber |
Failed |
Temperature threshold equal to or over 55º C |
Blinking Amber |
Failed |
Temperature threshold equal to or over 60º C |
Event (caution icon) |
Solid Green |
Good |
Normal operation of RAID controller and I/O Board |
Solid Amber |
Faulty/Failed |
Failed RAID controller or I/O Board |
Blinking Amber |
Faulty/Failed |
Indicates that the version of SES firmware or associated hardware
PLD code on one controller does not match that on the other controller (firmware
version mis-match) |
3510 Rear Panel LEDs
LED Name |
State |
Description |
Battery |
Solid Green |
Battery charged |
Blinking Green |
Battery charging |
Solid Amber |
Battery failed |
Activity |
Off |
Not busy, no I/O activity |
Blinking Green |
Busy, I/O activity |
Cache |
Off |
Clean cache |
Blinking Green |
Dirty cache, indicates if data is in memory and is not written
to disk yet |
Ethernet Link (active controller) |
Off |
Inactive connection |
Solid Amber |
Active link |
Ethernet Link (inactive controller) |
Off |
Active connection on inactive controller or on active connection |
Ethernet Active |
Flashing Green |
Busy |
RAID Controller |
Solid Green |
Good (secondary controller) |
Blinking Green |
Good (primary controller) |
Solid Amber |
Failed RAID controller or I/O module |
SFP Link (L) |
Off |
Empty or failed FC connection |
Solid Green |
Active good FC connection |
SFP Speed (S) |
Off |
1 Gbit |
Solid Green |
2 Gbit |
3511 Rear Panel LEDs
LED Name |
State |
Description |
Battery |
Solid Green |
Battery charged |
Blinking Green |
Battery charging |
Solid Amber |
Battery failed |
Activity |
Off |
Not busy, no I/O activity |
Blinking Green |
Busy, I/O activity |
Cache |
Off |
Clean cache |
Blinking Green |
Dirty cache, indicates if data is in memory and is not written to disk yet |
Ethernet link (active controller) |
Off |
Inactive connection |
Solid Amber |
Active link |
Ethernet link (inactive controller) |
Off |
Active connection on inactive controller or inactive connection |
Ethernet active |
Flashing Green |
Busy |
RAID Controller |
Solid Green |
Good (secondary controller |
Blinking Green |
Good (primary controller) |
Solid Amber |
Failed RAID controller or I/O module |
SFP link (L) |
Off |
Empty or failed FC connection |
Solid Green |
Active good FC connection |
SFP link (S) |
Off |
1 Gbit |
Solid Green |
2 Gbit |
Power Supply and Fan Module LEDs
LED Name |
State |
Description |
Power Supply/Fan |
Solid Green |
Power supply good and fas are good |
Solid Amber |
3510: Failed, one or more output voltages out-of-range* or fan
speed under 3150 RPM
3511: Failed, one or more output voltages out-of-range* or fan speed
under 4000 RPM |
* Voltage Thresholds: +5 VDC +/- .25VDC, +12VDC +/- .6 VDC