| 
 
 
Go to Sun Fire X4170 M2, X4270 M2, Oracle Exadata X2-2, X2-8Go to Netra X4270
 
 
 
| 511-1213 | 541-4081 |  
| System Board 
 | SF X4170 M2 / X4270 M2 / Oracle Exadata X2-2 /
 Oracle Exadata X2-8 /
 ZFS 7120 / 7320
 Assembly/FRU
 511-1213 + Tray
 Tray 541-2543
 
 |    
 
 
 
| 511-1213 | 542-0268 |  
| System Board 
 | Netra X4270 Assembly/FRU
 511-1213 + Tray
 Tray 341-6196
 
 |   
 Headers, Jumpers, LEDs, and Switches
     
      | LOCATION | PINS | SETTING | DESCRIPTION |   
      | J602 | 1-2 | Out | Clear SP Password (install to clear) |   
      | J603 | 1-2 | Out | SP Debug |   
      | J702 | 1-2 | Out | SP Disable |   
      | J705 | 1-2 | NA | Not Stuffed |   
      | J706 | 1-2 | NA | Not Stuffed |   
      | J2403 | 1-2 | In | BIOS Write Enable (default) |  
      | J2601 | 1-2 | Out | Manfacturing Mode (default) |   
      | J3302 | 1-2 | Out | CPLD Debug |   
      | J3402 | 1-3 | Out | Unknown |   
      | J3403 | 1-3 | Out | Unknown |   
      | J3404 | 1-3 | Out | Unknown |  
 
| Sun Fire X4170 M2 Codename: Lynx+ (Thelma) Sun Fire X4270 M2 Codename: Lynx 2U (Hyde+)
 Netra X4270 Codename: Aurigi
 Oracle Exadata X2-2 Codename: EX2-2 (Plus)
 Oracle Exadata X2-8 Codename: EX2-8 (Plus-Plus)
 Sun ZFS Storage 7120 Codename: Amber Road (Iwashi+)
 Sun ZFS Storage 7320 Codename: Amber Road (Maguro +)
 |  Notes
The minimum Solaris operating system is Solaris 10 10/09.
The System Board FRU includes two 250-1802 Cleaning  Wipes, andtwo 310-0065 Shin-Etsu X23-7783D Thermal Grease Syringes.
 Heatsink Notes
Use a 5/32" hex driver to remove and replace the heatsink screws.
Heatsink FRU 541-2545 includes Heatsink 310-0161, two 240-6751 SpringScrews,one 250-1802 Cleaning Wipe and one 310-0065 Shin-Etsu X23-7783D Thermal
 Grease Syringe. Heatsink 310-0161 is pre-greased with Shin-Etsu G751.
Heatsink FRU 541-3310 includes Heatsink 310-0211, two 240-6751 SpringScrews,one 250-1802 Cleaning Wipe and one 310-0065 Shin-Etsu X23-7783D Thermal
 Grease Syringe. Heatsink 310-0211 is pre-greased with Shin-Etsu G751.
 Memory Installation Notes
Install memory filler panel 350-1288 in all unused slots.
Install the first three DIMMs in CPU0 and CPU1 slots D8, D5, and D2.
Install the second three DIMMs in CPU0 and CPU1 slots D7, D4, and D1.
Use of the same DIMM size and speed is recommended for maximum performance.
 References
 Sun Fire X4170 M2 and X4270 M2 Installation Guide, 821-0481. Sun Fire X4170 M2 Service Manual , 821-0486. Sun Fire X4170 M2 and X4270 M2 Product Notes, 821-0482. Sun Fire X4170 M2 and X4270 M2 Installation Guide, 821-0481. Sun Fire X4270 M2 Service Manual , 821-0488.  Sun Fire X4170 M2 and X4270 M2 Product Notes, 821-0482. Netra X4270 Server Installation Guide, 821-0572. Netra X4270 Server Service Manual , 821-0573.  Netra X4270 Server Product Notes, 821-0577. 
 |