DC Power Distribution Board
501-7696 |
511-1604 |
|
March 2010 |
Sun Fire X4140 Codename: Dorado 1U
Sun Fire X4150 Codename: Doradi
Sun Fire X4170 Codename: Lynx 1U
SPARC Enterprise T5120 Codename: Huron 1U
SPARC Enterprise T5140 Codename: Maramba 1U
Storage 7310 Codename: Maguro
Storage 7310 SAS 2.0 Codename: SAS2.0
Storage F5100 Codename: Lightning Flash 1.0
Oracle Exadata V2 Codename: Quicksilver |
Notes
- PDB <= 501-7696-06 may cause intermittant DVD operation.
- PDB 501-7696-07 changes firmware reset timing for proper DVD operation.
- PDB 501-7696-10 changes firmware to resolve BugID 6806680.
- PDB 511-1604 only supports the SATA DVD. The PATA DVD is not supported.
- PDB 511-1604 is not available as a FRU. Use 501-7696.
- Access to the Sun Fire X4150 System Board busbar screws is blocked by the
CPU0 Heatsink.
Removal of the CPU0 Heatsink during the PDB replacement procedure is
required.
Clean and re-grease the Heatsink with Thermal Grease Kit F350-1271-01.
The kit includes Cleaning Wipe 250-1802 and ShinEtsu X23-7783D Thermal
Grease syringe 310-0065.
The kit is not included with the PDB.
SPARC Enterprise T5120 and T5140 Notes
- Program the chassis serial number into a replacement PDB
using the setscn command.
- Reference the Service Manuals for
T5120 and
T5140.
- See also How To article
1011586.1.
Storage F5100 Notes
- Program the chassis serial number into a replacement PDB
with the LF-PDB-Update tool.
- The LF-PDB-Update tool is not available for Linux or Windows.
- Reference Knowledge Article
1140044.1.
|