Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

DC Input Module

Servers: Sun Fire E2900
Telco: Netra 1280

370-5265

Sun Fire V1280 Codename: Lightweight 8

Notes

  1. DC Input Source A provides power to PS0 and PS1.
  2. DC Input Source B provides power to PS2 and PS3.
  3. Use power HYLUG connector YA6C-L1-90, 130-5146.
  4. Use ground HYLUG connector YAV6C-L2TC10-FX-90, 130-5147.
  5. Connectors 130-5146 and 130-5147 require #6 AWG wire.
  6. Connectors are sourced from Framatome Connectors International.
  7. Burndy mechanical crimping tool MD7-34R or equivalent is required.

References

  1. Sun Fire V1280/Netra 1280 Systems Service Manual, 817-0510.
  2. Sun Fire V1280/Netra 1280 System Administration Guide, 817-0509.
  3. Sun Fire V1280/Netra 1280 Systems Site Planning Guide, 817-3333.
  4. Sun Fire V1280/Netra 1280 Systems Installation Guide, 817-3334.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback