Delta A236-03
720 Watt Power Supply

Servers: SPARC Enterprise T5120

Option SECX9PS41Z

300-2234
Type A236-03
AC Input Power Supply
Specification 950-5844
UL 60950-1 2nd Edition
EN 60950-1 2nd Edition


AC Input

90-264Vac 47-63Hz 8.7A RMS Max

DC Output

+12V +3.3Vsb
59.2A 3.0A

Efficiency of 300-2234

100V 20-50% Load >=83-87%
100% Load 87%
230V 20-50% Load >=85-89%
100% Load 85%

SPARC Enterprise T5120 Codename: Huron 1U

Notes

  1. Power Supply Efficiency affects the current draw in AC Watts from the branch circuit. As efficiency increases, the current draw in AC Watts decreases.
  2. To calculate maximum theoretical current draw in AC Watts, multiply the maximum power supply output in DC Watts by the reciprocal of the power supply efficiency.
  3. Theoretical values are typically higher than published values which are based on measured outputs under controlled test conditions.