Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Option 964
AC Power Sequencer Operation

Switch SW1

Use SW1 to set the Slave Outputs when SW2 is set to 1.

Switch SW2

Use SW2 to set Switched=1, Remote=2, or Unswitched=3.

Switch SW3

Use SW3 to set the AC current detection level used when SW2 is set to Switched mode. Slave outputs are enabled when the AC current exceeds 200ma in the SS10 position or 600ma in the SS1000 position.

SW1 SW2 Master-1
Load
Master-2
Load
Slave-1
Output
Slave-2
Output
1
1
1
1
On
Off
x
x
On
Off
On
Off
2
2
2
2
1
1
1
1
On
On
Off
Off
Off
On
On
Off
On
On
Off
Off
Off
On
On
Off
3
3
3
1
1
1
On
Off
Off
x
On
Off
On
On
Off
On
On
Off
4
4
4
1
1
1
On
Off
Off
x
On
Off
On
Off
Off
On
On
Off
1234
1234
2
3
N/A
N/A
N/A
N/A
x
On
x
On

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback