Document Audience: | INTERNAL |
Document ID: | I1064-1 |
Title: | How to identify System Board FRUID change after CPU upgrade to Sun Fire V210/V240 and Netra 240 systems. |
Copyright Notice: | Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | 2004-02-18 |
---------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD INFORMATION NOTICE
(For Authorized Distribution by Sun Services)
FIN #: I1064-1
Synopsis: How to identify System Board FRUID change after CPU upgrade to Sun Fire V210/V240 and Netra 240 systems.Create Date: Feb/17/2004
SunAlert: No
Top FIN/FCO Report: No
Products Reference: Sun Fire V210/V240, Netra 240
Product Category: Server / Diag-Doc-Service
Product Affected:
Systems Affected:
-----------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- N31 All Sun Fire V210 -
- N32 All Sun Fire V240 -
- N54 All Netra 240 -
X-Options Affected:
-------------------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
X7406A - 1.0GHz CPU Upgrade Kit -
X7412A - 1.28GHz CPU Upgrade Kit -
Parts Affected:
----------------------
Part Number Description Model
----------- ----------- -----
375-3120 ASSY,M-BOARD,2X1.28GHZ,0MEG -
375-3122 Assy,M-BOARD,2X1.002GHZ,0MB -
375-3149 ASSY,M-BOARD,1X1.002GHZ,0MB -
375-3150 ASSY,M-BOARD,2X1.002GHZ,0MB -
375-3178 ASSY,0DM,BOARD,ENCHILADA MB 1X1.28GHZ CPU -
References:
BugID: 4911698
Manual: 817-4146-10, Sun Fire V210 and V240 Server, Netra 240 Server CPU
Upgrade Guide
URL: http://www.sun.com/servers/entry/cpu_upgrade_utility.html
http://edist.corp/edist-cgi/list_tools.cgi?division=Computer+Systems
http://wwws.sun.com/software/download/sys_admin.html
Issue Description:
After a CPU upgrade procedure is performed on Sun Fire V210/V240 and
Netra 240 servers, the Solaris "showfru" command is unable to display the
new System Board FRUID information. Instead, it will show the original
FRUID data.
A CPU upgrade kit was recently announced for the Sun Fire V210/V240 and
Netra 240 Servers. The CPU upgrade process writes the new configuration data
to the FE segment within the DYNAMIC section of the FRUID SEEPROM on the
System Board.
Because the CPU(s) and System Board is one FRU, the part number within the
SD segment (STATIC section) of FRUID SEEPROM on the System Board will not be
correct after an upgrade has been implemented.
The "showfru" command is not able to read the updated FRUID data. This new
data is only readable by the "prtfru" command using modified library
files which are available on the Upgrade CDROM.
The "showfru" command will be able to display the FE segment within the
DYNAMIC section of FRUID in the next release of Sun Advanced Lights Out
Management (ALOM) software. This version of ALOM (1.4) can be downloaded
from http://www.sun.com/software/download/sys_admin.html when it releases.
Downloads require that a user account be created.
Implementation:
---
| | MANDATORY (Fully Proactive)
---
---
| | CONTROLLED PROACTIVE (per Sun Geo Plan)
---
---
| X | REACTIVE (As Required)
---
Corrective Action:
The following recommendation is provided as a guideline for authorized
Sun Services Field Representatives who may encounter the above
mentioned issue.
Use the Solaris "prtfru" command to display the updated FRUID information
following a Sun Fire V210/V240 or Netra 240 CPU upgrade procedure.
The "prtfru" command will only display the FE segment within the
DYNAMIC section of FRUID if LD_LIBRARY_PATH is set to the Tools/lib directory
on the CDROM supplied as part of the CPU Upgrade kit. Use of the "prtfru"
command is detailed in the CPU Upgrade Guide 817-4146-10. The library
files are also available at URL:
http://edist.corp/edist-cgi/list_tools.cgi?division=Computer+Systems
(select "SunFire V210 V240 V250 and Netra 240 1.0")
They are available externally at URL:
http://www.sun.com/servers/entry/cpu_upgrade_utility.html
Note that as part of the Upgrade Procedure, it is important to also perform
the following:
1. Attach the correct System Board part number label (A,B,C,D)
to the System Board.
2. Attach the correct bezel label (W,X,Y,Z) to the front of the server bezel.
These labels are supplied with the CPU Upgrade Kit. A detailed procedure can
be found on page 26 of the Upgrade Manual.
Comments:
None.
============================================================================
Implementation Footnote:
i) In case of MANDATORY FINs, Sun Services will attempt to contact
all affected customers to recommend implementation of the FIN.
ii) For CONTROLLED PROACTIVE FINs, Sun Services mission critical
support teams will recommend implementation of the FIN (to their
respective accounts), at the convenience of the customer.
iii) For REACTIVE FINs, Sun Services will implement the FIN as the
need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
--------------
* Access the top level URL of http://sdpsweb.central/FIN_FCO/index.html
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.central/
* From there, select the appropriate link to browse the FIN or FCO index.
Internet Access:
----------------
* Access the top level URL of https://spe.sun.com
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to [email protected]
--------------------------------------------------------------------------