Document Audience:INTERNAL
Document ID:I1022-1
Title:I/O System Controller (IB_SSC) assemblies for Sun Fire V1280 and Netra 1280 have been incorrectly left in Manufacturing Mode.
Copyright Notice:Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved
Update Date:2005-01-05

------------------------------------------------------------
            - Sun Proprietary/Confidential: Internal Use Only -
------------------------------------------------------------------------  
                        FIELD INFORMATION NOTICE
               (For Authorized Distribution by SunService)
FIN #: I1022-1
Synopsis: I/O System Controller (IB_SSC) assemblies for Sun Fire V1280 and Netra 1280 have been incorrectly left in Manufacturing Mode.
Create Date: Oct/08/03
SunAlert: No
Top FIN/FCO Report: No
Products Reference: Sun Fire V1280 / Netra 1280
Product Category: Server / Service
Product Affected: 
Systems Affected:
-----------------  
Mkt_ID    Platform    Model     Description                Serial Number
------    --------    -----     -----------                -------------
  -         A40        ALL      Sun Fire V1280                   -
  -         N40        ALL      Netra 1280                       -  


X-Options Affected:
-------------------
Mkt_ID    Platform   Model     Description        Serial Number
------    --------   -----     -----------        -------------
 -           -         -            -                   -
Parts Affected: 
----------------------
Part Number    Description   	                                   Model
-----------    -----------   	                                   -----
540-5290-xx    I/O System Controller Bd (IB_SSC) Sun Fire V1280      -
540-5565-xx    I/O System Controller Bd (IB_SSC) Netra V1280         -
References: 
N/A
Issue Description: 
Sun Fire V1280 and Netra 1280 I/O System Controller (IB_SSC) FRUs have
been left in Manufacturing Mode.  As a result of this, the customer
could receive an I/O System Controller FRU which will allow them access
to commands never intended for customer use.

The affected part numbers are 540-5290 and the 540-5565.  Any FRUs with
these part numbers which were repaired by the Repair Vendor between May
2003 and August 26, 2003 are susceptible to this issue.  No shipments
out of Manufacturing are impacted.

To determine if an IB_SSC unit is in Manufacturing Mode, issue a "help"
command from the lom> prompt.  If you see commands such as "aft",
"fan", or "clock", the IB_SSC is in Manufacturing Mode.  You must have
access to the System Controller to determine if the board has the issue
or not.

Extra commands will be available in the help menu as noted above.  The
user will also be able to type "engineering" from the lom> prompt and
not be asked for a password.

Incomplete instructions provided by Sun caused the repair vendor to not
reset the I/O System Controller FRUs to the default user mode before
shipment.  As a result, units repaired between May 2003 and August 26,
2003 will likely have been left in Manufacturing Mode.  Newly
manufactured boards that were made available as FRUs are NOT affected.

Any existing 540-5290 and 540-5565 FRU in any RSL worldwide may have
this issue.  However, less than 20 of these units are believed to
currently be in the Logistics system.  Also, any of these FRUs used by
an engineer during the period mentioned above may also be affected
and should be checked.
Implementation: 
---
        |   |   MANDATORY (Fully Proactive)
         ---    
         
  
         ---
        |   |   CONTROLLED PROACTIVE (per Sun Geo Plan) 
         --- 
         
                                
         ---
        | X |   REACTIVE (As Required)
         ---
Corrective Action: 
The following recommendation is provided as a guideline for authorized
Sun Services Field Representatives who may encounter the above
mentioned issue.
          
If you've received either a 540-5290-xx or 540-5565-xx System
Controller, and it is determined they are in Manufacturing Mode, first
issue the following commands and record the output from these commands
to use to restore your system:


   From a Solaris prompt:
	
	eeprom
	
   From the OBP/ok prompt:

	show-devs
	printenv
	show-disks
	show-nets
	devalias

   From the lom> prompt:

	showeventreporting
	showescape
	showsc
	shownetwork
	showdate -v
	showboards -v

Next, take the System Controller out of Manufacturing Mode by issuing
the setdefaults command from the lom> prompt.  Note that this will
erase all current lom settings, so use the information gathered above
to restore any lost settings.

If for some reason setdefaults is not an acceptable solution, a
Radiance task for PTS should be initiated for alternative workarounds.
Comments: 
This is only for I/O System Controller (IB_SSC) replacement FRUs.
Systems shipped from the factory were not exposed to this issue.


============================================================================
Implementation Footnote: 
i)   In case of MANDATORY FINs, Sun Services will attempt to contact   
     all affected customers to recommend implementation of the FIN. 
   
ii)  For CONTROLLED PROACTIVE FINs, Sun Services mission critical    
     support teams will recommend implementation of the FIN  (to their  
     respective accounts), at the convenience of the customer. 

iii) For REACTIVE FINs, Sun Services will implement the FIN as the   
     need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access:
-------------- 
* Access the top level URL of http://sdpsweb.central/FIN_FCO/index.html

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.central/

* From there, select the appropriate link to browse the FIN or FCO index.

Internet Access:
----------------
* Access the top level URL of https://spe.sun.com
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to [email protected]
--------------------------------------------------------------------------