Document Audience:INTERNAL
Document ID:I0705-1
Title:P/N change on PSU for U5/U10 since Jan/01/01
Copyright Notice:Copyright © 2005 Sun Microsystems, Inc. All Rights Reserved
Update Date:2001-08-03

---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                            FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)
FIN #: I0705-1
Synopsis: P/N change on PSU for U5/U10 since Jan/01/01
Create Date: Aug/03/01
Keywords: 

P/N change on PSU for U5/U10 since Jan/01/01

SunAlert: No
Top FIN/FCO Report: No
Products Reference: Ultra 5/Ultra 10 PSU
Product Category: Desktop / Service
Product Affected: 
Mkt_ID   Platform   Model   Description   Serial Number
------   --------   -----   -----------   -------------
Systems Affected
----------------
  -        A21       ALL    Ultra 5             -
  -        A22       ALL    Ultra 10            -

X-Options Affected
------------------
  -         -         -          -              -
Parts Affected: 
Part Number   Description                    Model
-----------   -----------                    -----
370-3162-02   POWER SUPPLY 200W ULTRA 5        -
370-3171-02   POWER SUPPLY 250W ULTRA 10       -
370-4326-01   POWER SUPPLY 200W A-PFC          -
370-4325-01   POWER SUPPLY 250W A-PFC          -
References: 
ECO:    WO_19504

Manual: 805-7763-10 - Sun Ultra 5 Service Manual.
        805-7764-10 - Sun Ultra 10 Service Manual.
                             
URL:    http://infoserver.central/data/sshandbook/Systems/U5/repair.html
Issue Description: 
This FIN is to notify the field of a part change on the Sun Ultra 5
or Ultra10 Power Supply Unit.  Effective  Jan/01/2001, the PSU part
number will change from 370-3162-xx/370-3171-xx to
370-4326-xx/370-4325-xx respectively.  The new U5/U10 PSU
(370-4326-xx/370-4325-xx) is backward compatible.  However, the old PSU
(P/N# 370-3162-xx/370-3171-xx) is not forward compatible.  Both PSU's
will be carried as FRU's. 

The new PSU incorporates changes (specifically an auto-sensing/power
factor correction feature) making the Sun Ultra5/Ultra10 system fully
CE compliant.  Accordingly, the new PSU's do NOT have an incoming
voltage selection switch.  Field Engineers should be aware of this change and
should not attempt to set the incoming voltage switch on the new PSU's
as this step is now taken care of automatically by the PSU internal
circuitry.  FE's should also order the same part number in the event a
replacement is neccessary.

Systems containing the new PSU can be identified by inspecting the EZ label.
Units with the new PSU are marked with BC"D" SERIES 3.

The part number change was necessary due to a European power source
auto-switching requirement to make the new PSU fully CE compliant.
Implementation: 
---
        |   |   MANDATORY (Fully Pro-Active)
         ---    
         
  
         ---
        |   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
         --- 
         
                                
         ---
        | X |   REACTIVE (As Required)
         ---
Corrective Action: 
An Authorized Enterprise Services Field Representative may avoid the
above mentioned problems by following the recommendations as shown below.

When Power Supply Unit replacements are required for Ultra5/Ultra10
systems, Field Engineers should replace the defective PSU with the same
part number.  That is, if you remove a 370-4326-xx you should replace
it with a 370-4326-xx.  If you remove a 370-3162-xx, replace it with
the same.

Removal and installation procedures for the PSU can be found in the Sun 
System Handbook online at:
 
   http://infoserver.central/data/sshandbook/Systems/U5/repair.html
Comments: 
--------------------------------------------------------------------------
Implementation Footnote: 
i)   In case of MANDATORY FINs, Enterprise Services will attempt to    
     contact all affected customers to recommend implementation of 
     the FIN. 
   
ii)  For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical    
     support teams will recommend implementation of the FIN  (to their  
     respective accounts), at the convenience of the customer. 

iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the   
     need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access:
-------------- 
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
  accessed internally at the following URL: http://edist.corp/.
  
* From there, follow the hyperlink path of "Enterprise Services Documenta- 
  tion" and click on "FIN & FCO attachments", then choose the appropriate   
  folder, FIN or FCO.  This will display supporting directories/files for 
  FINs or FCOs.
   
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to [email protected]
---------------------------------------------------------------------------
                                                        


------------- End Forwarded Message -------------