  Goal
  Solution


Applies to:

Sun Fire V445 Server - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Goal

How to remove and replace a Sun Fire V445 HDD

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
V445 Product Training or Experience

DELIVERY REQUIREMENT:
As scheduled

TIME ESTIMATE: 30 Minutes

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:
Faulty Disk

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The operating system should be configured by the customer such that the disk drive is free for replacement.
e.g. The disk may be part of Solaris Volume Manager, Veritas Volume Manager, mounted file-system, raw partitions, etc.
A data backup may be required to restore data onto a replaced disk.
If a data backup is not required it is still a wise precaution.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Identify the hard drive to be removed and note the bay in which it is installed
2. Remove the hard drive from the device tree using the following command:
# cfgadm -c unconfigure c1::dsk/c1t3d0
where c1t3d0 is the name of the hard drive to be removed.
The blue OK to Remove hard drive indicator lights.
3. Allow the disk to spin down completely.
4. Physically remove the hard drive from the system.
5. Insert the hard drive into its bay.
6. Configure the new hard drive using this command:
cfgadm -c configure c1::dsk/c1t3d0
where c1t3d0 is the name of the hard drive to be removed.
The blue OK to Remove indicator goes out, and the green Activity indicator flashes

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

All disks should be visible under format command
Reconfigure disk as previously configured. e.g. Part of raid set or mounted file-system or raw partition or other