Sun [TM] Explorer 5.1 and later have the capability to collect data from ALOM that is useful for troubleshooting.


Steps to Follow
How To Get Sun [TM] Explorer To Collect ALOM Data

Here are some points to take note of before Sun Explorer is run.

1) The system must have the ALOM "NET MGT" port connected and configured.
It is suggested to test the "NET MGT" port by manually telnet'ing into it.

Note: < Document: 1004884.1 > explains how to configure the "NET MGT" port.

2) The ALOM script (alomextended) is not run by default,it must be specified.

Example of running just the ALOM script:

   /opt/SUNWexplo/bin/explorer -w !default,alomextended

Example of running the default scripts and alomextended

   /opt/SUNWexplo/bin/explorer -w default,alomextended

3) A configuration file must be populated as shown below.If this is not done
the script will pause and require the info to be entered interactively.

The file name is:

   /etc/opt/SUNWexplo/alominput.txt

The default contents are:

   # Input file for extended data collection
# Format is HOST USERNAME PASSWORD 
# Explorer requires the mode of alominput.txt is 0600

Example of a populated file:

   # Input file for extended data collection
# Format is HOST USERNAME PASSWORD 
# Explorer requires the mode of alominput.txt is 0600 pts-alom-net admin admin1

The critical part of this is to know that the "HOST" is the name associated with the IP address of the "net mgt" port and not the system's hostname. Using the IP address of the "net mgt" port will also work for the "HOST" setting. Also the "USERNAME" and "PASSWORD" are for the ones used to log into ALOM on the "net mgt" port. This file must have permission set to 0600.

4) The default ALOM prompt of "sc>" must be in use. The script will not run with a customized prompt (BugID 6324558 Click Here).

Below is an example of the path explorer will save the ALOM data and what is collected:

# pwd
/opt/SUNWexplo/output/explorer.83295e2b.pts-lab-2005.09.08.19.20/sc/pts-alom-net
# ls
consolehistory_-e_100.out  shownetwork_-v.out
showdate.out               showplatform_-v.out
showenvironment.out        showsc_-v.out
showfru.out                showusers.out
showlocator.out            usershow.out
showlogs_-e_100.out
# 

Please also see < Document: 1002383.1 > for further Sun Explorer information.



Product
Sun Fire V240 Server
Netra 240 Server
Netra 440 (AC) Server
Netra 440 Server
Netra 240 Server (AC)
Sun Fire V210 Server
Sun Fire V440R Server
Sun Fire V440 Server
Advanced Lights Out Manager 1.1
Advanced Lights Out Manager 1.0
Advanced Lights Out Manager 2.0
Sun Fire V250 Server
Sun Fire V445 Server
Sun Fire V245 Server

explorer, alom, v210, v240, v440, v250, alomextended, v215, v245, v445
Previously Published As
82460

Change History
Date: 2010-04-19
User Name: 79977
Action: Currency check
Comment: Verified still current by CL [email protected]
Date: 2007-05-17
User Name: 31620
Action: Approved
Comment: Verified Metadata - ok
Verified Keywords - ok
Verified still correct for audience - currently set to contract
Audience left at contract as per FvF at
http://kmo.central/howto/content/voyager-contributor-standards.html
Checked review date - currently set to 2007-10-23
Checked for TM - ok as presented
Publishing under the current publication rules of 18 Apr 2005:
Checked for the word normalized - not nrml. content
Version: 19
Date: 2007-05-17
User Name: 31620
Action: Accept
Comment:
Version: 0
Date: 2007-05-17
User Name: 35315
Action: Approved
Comment: ok
Version: 0

Product_uuid
18d48708-5867-11d6-8128-c95a9ce59853 | Sun Fire V240 Server
e246cdea-356f-11d7-9f99-8fabc2ef0f34 | Netra 440 Server
4a78cce8-2fe3-11d7-9239-f5e838e9bb7a | Netra 240 Server


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback