Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1004783.1 : Netra [TM] 20 LOMlite2 Firmware Update
PreviouslyPublishedAs 206641 Description Netra [TM] 20 LOMlite2 Firmware Update. Steps to Follow LOMlite2 Firmware Update The Netra 20 systems are currently supplied with LOMlite 2 firmware revision 4.4. The firmware must be upgraded to revision 4.5 to enable: Reporting of the DC PSU status Correct functionality of a modem when connected to the LOMlite2 serial port To update the Lights Out Management firmware you must obtain the latest revision of Patch ID 110208 (revision 11 or later) from SunSolve. The firmware update procedure is described below.
Adding LOMlite2 Patch ID 110208 Ensure you have the latest revision of Patch ID 110208 from SunSolve[TM] (revision -11 or later). The LOMlite2 software will not function unless this patch is added.
Confirm the base LOMlite2 firmware version. Type #. to change to the lom> prompt, then run version . #. lom> version
LOM version: v4.4-LW2+ LOM checksum: 387e LOM firmware part# 258-7939-12 Microcontroller: H8S/2148 LOM firmware build Aug 30 2001 18:02:40 Configuration rev. v1.2
lom> console
The LOM firmware version must not be earlier than 4.5. Type console at the lom> prompt to return to the # prompt.
Confirm that the device node is present (via PROM 4.2.4):
# prtconf -V OBP 4.2.4 2001/06/13 10:10 # prtconf | grep SUNW,lomv SUNW,lomv (driver not attached)
Copy the patch to a temporary directory ( /var/tmp ). Confirm that the patch is present: # cd /var/tmp # ls 110208-11.zip Extract the patch: # unzip 110208-11.zip Apply the patch. # patchadd 110208-11 # reboot
Confirm that the patch has been loaded: # modinfo | grep lomv
To upgrade the firmware, type: # lom -G default When prompted, type C to continue. This process takes several minutes. Do not turn off the system while the update is progressing. Press Return to redisplay the Unix prompt.
If the system displays the ok prompt, type go to return to the Unix prompt.
Check the functionality by running the lom -a command: # lom -a PSUs: 1 OK Fans: 1 OK speed 90% 2 OK speed 86% 3 OK speed 75%
LOMlite configuration settings: serial escape character=# serial event reporting=default Event reporting level=fatal, warning & information Serial security=enabled Disable watchdog on break=enabled Automatic return to console=disabled alarm3 mode=user controlled firmware version=4.5 firmware checksum=1164 product revision=1.4 product ID=Netra T4 . <truncated> . LOMlite led states: 1 on Power 2 off Fault 3 off Supply A 4 off Supply B 5 on PSU ok 6 off PSU fail #
The software is now installed and the system is ready for use. Product Advanced Lights Out Manager 2.0 Netra 20 Server Internal Comments For internal Sun use only.
Previously Published As 49125 Change History Date: 2003-05-20 User Name: Administrator Action: Migration from KMSCreator Comment: updated by : Robin Dole comment : No comment date : Jan 9, 2003 updated by : Suda Vang comment : ready to be submitted date : Jan 8, 2003 updated by : Ronald Neese comment : Article created. date : Nov 27, 2002 updated by : Ronald Neese comment : No comment date : Nov 27, 2002 updated by : Claude Flom comment : No comment date : Nov 27, 2002 Version: 0 Attachments This solution has no attachment |
||||||||||||
|