Solution Type Technical Instruction Sure Solution 1003857.1 : Sun Fire[TM] V210/V240: mixing DIMMs of differing capacities
PreviouslyPublishedAs 205413
Applies to:Sun Fire V210 ServerSun Fire V240 Server All Platforms GoalMixing DIMMs of differing capacity within a system is supported in the Sun Fire[TM] v210 and Sun Fire[TM] v240 servers.SolutionOracle Confidential (INTERNAL). Do not distribute to customersReason: Migrated distribution from Sun Description Mixing DIMMs of differing capacity within a system is supported in the Sun Fire[TM] v210 and Sun Fire[TM] v240 servers. Steps to Follow When the V210 and V240 servers were initially released the supported memory configurations only allowed for the system to contain memory DIMMs of the same capacity to be installed within the system. This is no longer the case. These servers can now be configured so that different banks can have different capacities of memory within a system. So a current system may now be upgraded using DIMMs that have a different capacity than the DIMMs that already occupy the server. However the memory DIMMs within a bank MUST still be a matched set . This requirement has not changed. Within a bank the DIMMs must be of the same capacity, manufacturer, speed, part number, and SPD type. Please note that for the memory controller to be able to implement DIMM to DIMM interleaving the system must contain memory of all the same capacity. When configured with an unbalanced memory configuration the memory controller's inability to optimize interleaving will result in a slight decrease in the memory's performance potential. Product Sun Fire V240 Server Sun Fire V210 Server Internal Comments This information is documented in the "Just the facts" documents for the V210 and V240 which can be found in the "Related Documentation" section of the product's Sun System Handbook page. The memory configuration rules have also been updated in the service manual to reflect this newly allowed configuration (see section 1.11.1) Sun Fire V210 and V240 Servers Service Manual memory, interleaving, DIMM, mixed, capacity Previously Published As 81978 Change History Date: 2010-05-25 User name: Anthony Rulli Action: reviewed/updated Comments: Currency check, audited by Dencho Kojucharov, Entry-Level SPARC Content Lead Product_uuid 18d48708-5867-11d6-8128-c95a9ce59853|Sun Fire V240 Server dc751a7c-eece-4157-8e4e-376351aa49fa|Sun Fire V210 Server Attachments This solution has no attachment |
||||||||||||
|