Goal

Description

Sun Fire[TM] V210 and Sun Fire[TM] V240 servers have two serial ports, labelled SERIAL MGT and 10101.

Which serial port should I use?

Solution


Steps to Follow

On a Sun Fire[TM] V210/v240 the SERIAL MGT port accepts an RJ-45 connector.
This port is designed for Advanced Lights Out Management (ALOM) and system console use only.

Note: Do not attach any general purpose serial devices such as serial printer, UPS, modem to this
port.


The port labeled 10101 accepts a DB-9 connector, this is the port to be used for general purpose serial data transfer.

The default serial connection settings are listed as shown:

Parameter Setting
Connector SERIAL MGT or 10101
Rate 9600 baud
Parity None
Stop bits 1
Data bits 8

If you need to connect to the SERIAL MGT port using either a DB-9 or a DB-25 connector, use an adapter to perform the crossovers given as shown:

RJ-45 to DB-9 Adapter Crossovers
Serial Port (RJ-45 Connector) Pin Adapter (DB-9) Pin
1 (RTS) 8 (CTS)
2 (DTR) 6 (DSR)
3 (TXD) 2 (RXD)
4 (Signal Ground) 5 (Signal Ground)
5 (Signal Ground) 5 (Signal Ground)
6 (RXD) 3 (TXD)
7 (DSR) 4 (DTR)
8 (CTS) 7 (RTS)
RJ-45 to DB-25 Adapter Crossovers
Serial Port (RJ-45 Connector) Pin Adapter (DB-25) Pin
1 (RTS) 5 (CTS)
2 (DTR) 6 (DSR)
3 (TXD) 3 (RXD)
4 (Signal Ground) 7 (Signal Ground)
5 (Signal Ground) 7 (Signal Ground)
6 (RXD) 2 (TXD)
7 (DSR) 20 (DTR)
8 (CTS) 4 (RTS)


Product
Sun Fire V240 Server
Sun Fire V210 Server

V210, V240, Enchilada, Serial Port, ALOM
Previously Published As
73815

Change History
Date: 2010-10-12
User Name: Silvana Villamil
Action: process comments
Comments: audited/updated by Silvana Villamil, Entry Level SPARC Content Team Member

Expanded acronym ALOM
Publishing
Version: 4
Date: 2005-01-04
User Name: 72228

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback