Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1019824.1 : Sun Fire V215 and V245 Servers may Experience an Erroneous "Overtemp" Alarm Causing the System to Power Off
PreviouslyPublishedAs 246946 Bug Id <SUNBUG: 6662423> Product Sun Fire V215 Server Sun Fire V245 Server Date of Resolved Release 05-Dec-2008 Sun Fire V215 and V245 servers may experience an erroneous transient overtemp alarm resulting in an abrupt power off of the system: 1. Impact Sun Fire V215 and V245 servers may experience an erroneous transient "overtemp" alarm resulting in an abrupt power off of the system without a graceful shutdown of Solaris. When this occurs the "OVERTEMP LED" will be lit (amber) even though there is no genuine overtemp condition being experienced. 2. Contributing Factors This issue can occur on the following platforms:
3. Symptoms If the described issue occurs, messages similar to the following will be seen in the ALOM event log ("showlogs" command): Feb 02 10:46:16 : 00040029: "Host system has shut down."In addition, the "OVERTEMP LED" on the front of the system chassis will be lit (amber). This LED status can also be confirmed with the ALOM "showenvironment" command. Meanwhile, all the sensors have an "OK" status. Outputs similar to the following will be logged to "SYS.OVERTEMP": sc> showenvironment4. Workaround There is no workaround for this issue. Please see the Resolution section below. 5. Resolution This issue is addressed on the following platforms:
EPIC update completed successfully.If "epicupdate" fails with the following error: EPIC image verification failed. Bad record 0x0please retry until "epicupdate" completes successfully. This Sun Alert notification is being provided to you on an "AS IS" basis. This Sun Alert notification may contain information provided by third parties. The issues described in this Sun Alert notification may or may not impact your system(s). Sun makes no representations, warranties, or guarantees as to the information contained herein. ANY AND ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT, ARE HEREBY DISCLAIMED. BY ACCESSING THIS DOCUMENT YOU ACKNOWLEDGE THAT SUN SHALL IN NO EVENT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES THAT ARISE OUT OF YOUR USE OR FAILURE TO USE THE INFORMATION CONTAINED HEREIN. This Sun Alert notification contains Sun proprietary and confidential information. It is being provided to you pursuant to the provisions of your agreement to purchase services from Sun, or, if you do not have such an agreement, the Sun.com Terms of Use. This Sun Alert notification may only be used for the purposes contemplated by these agreements. Copyright 2000-2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, CA 95054 U.S.A. All rights reserved. Modification History 12-Mar-2009: Updated the Resolution section. References<SUNPATCH: 139735-01>Internal Comments Please send technical questions to the following email: [email protected] and CC the following persons: Internal Contributor/Submitter Internal Eng Responsible Engineer Internal Contributor/submitter [email protected] Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 1-24061061, 1-23455734, 1-24742320, 1-24768456, 1-24768468, 1-24331811, 1-24944610, 1-24375604, 1-24792128, 1-24969094, 1-24969172, 1-23340351, 1-24283337, 1-24254369, 1-24223046, 1-23889832, 1-24229566, 1-24476620, 1-24208069, 1-24206981, 1-24208163, 1-24208181, 1-24146961, 1-23928924, 1-24398342, 1-24103540, 1-24028726 Internal Eng Business Unit Group Systems Group - SVS (SPARC Volume Systems, Horizontal Systems, T1000/T2000 and Ontario) Internal Resolution Patches 139735-01 Internal Sun Alert & FAB Admin Info WF 12-Mar-2009, jfolla: Added a note to the resolution section per engineer. WF 05-Dec-2008, jfolla: sent to publish WF 03-Dec-2008, jfolla: sent for 24hr review WF 03-Dec-2008, jfolla: created ReferencesSUNPATCH:139735-01Attachments This solution has no attachment |
||||||||||||
|