Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1010567.1 : Sun Fire[TM] V240 bge IF has high error rate at Cisco Catalyst WS-C4006
PreviouslyPublishedAs 214540 Symptoms A link between a Sun Fire [TM] V240 with a bge interface and a Cisco Catalyst WS-C4006 is not established well as long as the ports - are left in default configuration or - are set to 1Gb/s full-duplex forced (autonegotiation off). The link shows poor performance due to high input packet errors at the bge interface. # netstat -i 10 input bge0 output input (Total) output packets errs packets errs colls packets errs packets errs colls 29804 25911 56433 0 0 29881 25911 56510 0 0 29064 23963 54946 0 0 29064 23963 54946 0 0 Resolution Set the bge interface to 1Gb/s full-duplex fixed with autonegotiation enabled at the SF V240 and also enable autonegotiation at the Cisco Catalyst WS-C4006 port: Example for bge0: # ndd -set /dev/bge0 adv_1000fdx_cap 1 # ndd -set /dev/bge0 adv_1000hdx_cap 0 # ndd -set /dev/bge0 adv_100fdx_cap 0 # ndd -set /dev/bge0 adv_100hdx_cap 0 # ndd -set /dev/bge0 adv_10fdx_cap 0 # ndd -set /dev/bge0 adv_10hdx_cap 0 # ndd -set /dev/bge0 adv_autoneg_cap 1 For more information on bge interface read Technical Instruction <Document: 1001843.1> "bge Gigabit Ethernet - First Checks". Product Sun Fire V240 Server Sun Gigabit Ethernet PCI Adapter Sun Fire V210 Server Internal Comments Internal PTS Product Page: http://pts.emea/comms/products/bge/ bge, Cisco, Catalyst Previously Published As 72197 Change History Date: 2006-01-17 User Name: 18392 Action: Update Canceled Comment: *** Restored Published Content *** SSH Audit Version: 0 Date: 2006-01-17 User Name: 18392 Action: Update Started Comment: SSH Audit Version: 0 Attachments This solution has no attachment |
||||||||||||
|