Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1005319.1 : Sun Fire[TM] V215/V245 Server: FIOB.T_AMB Temp Status Critical
PreviouslyPublishedAs 207429 Symptoms System will not power up. The ALOM "poweron" command gets issued and returns no error but system does not power up. A look at the "showenvironment" ouput shows: -------------------------------------------------------------------------------- System Temperatures (Temperatures in Celsius): -------------------------------------------------------------------------------- Sensor Status Temp LowHard LowSoft LowWarn HighWarn HighSoft HighHard -------------------------------------------------------------------------------- CPU temperature information cannot be displayed when System power is off. FIRE I/O temperature information cannot be displayed when System power is off. FIOB.T_AMB CRITICAL -64 -15 -10 0 45 47 50 PDB.T_DISK OK 36 -15 -10 0 55 65 70 PDB.T_PS0 OK 35 -15 -10 0 48 50 53 PDB.T_PS1 OK 35 -15 -10 0 48 50 53 Resolution Problem was actually the top cover interlock switch not being made. The symptom could be misleading and cause one to think there was a defective FIOB or other temperature related condition. Relief/Workaround Product Sun Fire V245 Server Sun Fire V215 Server v215, v245, temp, critical.FIOB, AMB, poweron, ALOM, FIOB.T_AMB, switch, top cover, power Previously Published As 88723 Change History Date: 2007-03-14 User Name: 97961 Action: Approved Comment: - Changed title to comply to the standard format - Applied trademarking where it is missing Version: 3 Date: 2007-03-14 User Name: 97961 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|