Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1003659.1
Update Date:2011-01-24
Keywords:

Solution Type  Problem Resolution Sure

Solution  1003659.1 :   How to address "VOLTAGE_SENSOR @ MB.BAT.V_BAT has exceeded low warning threshold." messages on the Sun Fire[TM] V210 and Sun Fire V240 servers  


Related Items
  • Sun Fire V240 Server
  •  
  • Sun Fire V210 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
205170


Symptoms
If the 3v battery located on the motherboard of the Sun Fire[TM] V210 or Sun Fire[TM] V240 fails (or is removed for any reason) then ALOM will send out an alert informing the user of this fact. for example:
SC Alert: VOLTAGE_SENSOR @ MB.BAT.V_BAT has exceeded low warning threshold.

You can also check the battery status by running the prtdiag -v command from Solaris[TM].
Here is an example of the voltage section of prtdiag -v output with a failed battery ==>

--------------------------------
Voltage sensors:
-------------------------------
Location   Sensor        Status
-------------------------------
MB/P0      V_CORE        okay
MB/P1      V_CORE        okay
MB         V_VTT         okay
MB         V_GBE_+2V5    okay
MB         V_GBE_CORE    okay
MB         V_VCCTM       okay
MB         V_+2V5        okay
MB         V_+1V5        okay
MB/BAT     V_BAT         warning (0.53V)
PS0        P_PWR         okay
MB         FF_POK        okay
PS0        FF_UV         okay
PS0        FF_OV         okay
--------------------------------------------------


Resolution
The battery that resides on the motherboard for these servers is now a FRU part so it can be ordered and replaced independently of the motherboard. To minimize downtime and needless parts replacement when this battery fails it is recommended that the battery FRU part# 371-0090 be ordered and replaced.


Product
Sun Fire V210 Server
Sun Fire V240 Server

Internal Comments
Audited/updated 12/03/09 - [email protected], Entry Level SPARC Content Team Member

To locate the battery please see the Sun System Handbook's motherboard diagram. The battery is labeled BR2032 on the board:

https://support.us.oracle.com/handbook_internal/Devices/System_Board/SYSBD_SunFireV2x0_CPU.html

V210, V240, battery, voltage, replacement
Previously Published As
81366

Change History
Date: 2005-05-10
User Name: 25440
Action: Approved
Comment: Publishing.
Version: 6
Date: 2005-05-10
User Name: 25440
Action: Accept
Comment:
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback