Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire V480 : Archived FINs and FCOs

Implementation (Impl.):
M = Mandatory (Fully Pro-Active)

C = Controlled Pro-Active (per Sun Geo Plan)

U = Upon Failure
R = Reactive (As Required)

FAB Implementation Synopsis Last Modified Date
A0253-1 C A sub-population of DIMMs that shipped between 2001 and 2002 on the below platforms are showing significantly lower reliability than expected. Aug 18 2005
A0240-1 U Certain 1Gb PCI Dual FC Network Adapter+ (X6727A HBA) may cause internal disks of Sun Fire V480/V880 to not be recognized on boot or cause the FC loop B (HBA Port 1) to be unstable. Sep 01 2004
A0226-1 U Sun Fire V480 system may experience a fatal reset and reboot with "ERROR: System "FATAL RESET" from DAR/DCS/CDX". Apr 23 2004
A0223-1 U On Sun systems, a small number of 256MB DIMMs may experience Uncorrectable Memory Errors (UE). Mar 23 2004
I0908-1 R Sun Fire V880 and V480 systems will not boot with UltraSPARC III+ Mask 2.3 CPUs unless correct firmware is installed. 2002-12-02
I0888-1 R Power management issue causes loss of access to internal fiber channel disks on the Sun Blade 1000/2000, Sun Fire V880, V480, and 280R. 2002-11-26
I0887-1 R Guidelines for understanding and diagnosing UltraSPARC III Level 2 (L2) SRAM Cache Memory Errors. 2002-10-07
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback