Processor |
Number |
One to four |
Architecture |
UltraSPARC® IIIi (1.062, 1.28, or 1.593 GHz) |
Cache memory |
64 KB data, 32 KB instruction and 1 MB integrated L2 |
Main Memory |
Capacities |
4 DIMM slots per processor
Registered DDR-1 SDRAM
System configurations from 2 GB to 32 GB
|
Standard Interfaces |
Ethernet |
Two 10/100/1000 BaseT Ethernet
One 10 BaseT Ethernet (network management)
|
PCI |
Six internal PCI 2.2 compliant expansion slots:
Three 64 bit 33/66 MHz 3.3V full-length (slots 2, 4, 5)
Three 64 bit 33 MHz 5V full-length (slots 0, 1, 3)
|
SCSI |
One Ultra320 SCSI (LVD) |
System Configuration Card |
Front accessible for transfer of system configuration information,
including host ID |
Serial |
One TIA/EIA-232-F asynchronous (DB9) Port
One TIA/EIA-232-F (RJ45) Port (management)
|
USB |
Four OHCI-1.1 Compliant Interfaces, supporting dual speeds of
12 and 1.5 Mbits/sec each |
Internal Mass Storage |
Disks |
Up to four hot plug Ultra320SCSI 36GB, 73GB, or 146GB Disks |
DVD-ROM |
One Slim-line ATAPI DVD-ROM |
Environment |
AC input |
90 - 264 V AC (47- 63 Hz) |
Input power |
650 W (Max)
570 W (Typical)
|
Heat output |
2218 Btu/hr for operation @ 100 VAC to 240 VAC |
Temperature |
Operating: 5°C to 40°C (41°F to 104°)
Nonoperating: -40°C to 60°C (-40°F to 140°) |
Humidity |
Operating: 20% to 80% relative humidity, noncondensing, 27°C
max wet bulb
Nonoperating: Up to 93% relative humidity, noncondensing, 38°C
max wet bulb |
Altitude |
Operating: Up to 3000m, maximum ambient temperature is derated
by 1°C per 500m above 500m
Nonoperating: Up to 12000m
|
Acoustic noise |
Operating: 6.7 Bels
Idling: 6.7 Bels |
Vibration |
Operating: 0.0001 g2/Hz, 5 to 150 Hz, -12db/octave
slope 150 to 500 Hz
Nonoperating: 0.001 g2/Hz, 5 to 150 Hz, -12db/octave
slope 150 to 500 Hz |
Shock |
Operating: 3.0 g peak, 11 milliseconds half-sine pulse
IEC 60068-2-27
Nonoperating: 15.0 g peak, 11 milliseconds half-sine pulse; 1.0 inch
roll-off front to back, 0.5 inch roll-off side to side
IEC 60068-2-27 |
Handling Drops |
60 mm, 1 drop per corner, 4 cornersIEC 60068-2-31 |
Threshold Impact |
0.85m/s, 3 impacts per caster, all 4 casters, 25 mm step-upETE
1010-01 |
Number of cords |
2 (max) |
Regulations
Meets or exceeds the following requirements:
|
Safety |
UL approval to UL 60950, EN60950, C22.2 No.60950, and CB Report for IEC
950; all including Amendments 1, 2, 3, 4 and 11 and full worldwide
deviations. TUV approval to EN60950/IEC 950. GOST languages Certification
for Eastern Block countries. Korean MIC Certification. China CCC mark using
UL as agent. CE Declaration of Conformance (SMI self-declaration) to The
Electromagnetic Compatibility Directive and Low Voltage Directive with
accompanying "Technical Data File". Approval to Argentinian
standards using UL as agent. |
RFI/EMI |
47 CFR 15B (Code of Federal Regulations, Part 15, Subpart B) Class A;
EN55022 Class A per EMC Directive 89/336/EEC (CE Mark); VCCI Class A;
Industry Canada ICES-003; AS/NZ 3548 (Australia/New Zealand); CNS 13438
(Taiwan); KSC 5858 (MIC Mark/Korea) |
Immunity |
IEC 1000
EN55024 per EMC Directive 89/336/EEC, including
IEC 61000-4-2 Electrostatic discharge immunity test
IEC 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity
test
IEC 61000-4-4 Electrical fast transient/burst immunity test
IEC 61000-4-5 Surge immunity test
IEC 61000-4-6 Immunity to conducted disturbances, induced by radio frequency
fields
IEC 61000-4-8 Power frequency magnetic field immunity test
IEC 61000-4-11 Voltage dips, short interruptions and voltage variations
immunity tests
|
Line Distortion |
EN 61000-3-2 per EMC Directive 89/336/EEC |
Voltage Fluctuations and Flicker |
EN 61000-3-3 per EMC Directive 89/336/EEC |
Clearance and Service Access |
Front |
36 in.(91.4 cm) |
Rear |
36 in.(91.4 cm) |
Dimensions and Weights |
Height |
174 mm (6.85 in.) |
Width |
440 mm (17.3 in.) |
Depth |
635 mm (25 in.) |
Weight |
37 kg (82 lb.) fully configured |
Rack Mounting |
Fits into a standard 19-inch-wide rack mount kit that complies
with EIA-310-D-1992 standard |