Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] V250 Server: Hardware Specifications

Processor
Number Up to two
Architecture UltraSPARC[tm] IIIi (1.06GHz or 1.28GHz), 64-bit, 4-way Superscaler SPARC V9
Cache memory 64 KB data, 32KB instructions & 1 MB Integrated L2
Main Memory
Capacities

4 DIMM slots per processor

Registered DDR-1 SDRAM (PC2100) 128 bit plus ECC databus. System Configurations from 512MB to 8 GB

Standard Interfaces
Ethernet One 10/100/1000Base-T Ethernet port
PCI Six internal PCI 2.2 compliant expansion slots:
Three full-length 64-bit 33/66 MHz, 3.3V (slots 2, 4, 5)
Three full-length 64-bit 33 Mhz, 5V (slots 0, 1, 3)
SCSI One Ultra160 SCSI Multimode (SE/LVD)
System Configuration Card Front accessible for transfer of system configuration information, including host ID
Network Management One 10Base-T Ethernet port
Keyboard and mouse USB, each uses one of the four standard USB (Type A) ports
Parallel One parallel port (DB25)
Serial One TIA/EIA-232-F asynchronous (DB9) Port
Serial Management One TIA/EIA-232-F (RJ45) Port
USB Four OHCI 1.0-compliant interfaces, supporting dual speeds of 12 and 1.5 Mbits/sec each
Internal Mass Storage
Disks Up to 8 hot-swap Ultra160SCSI 36-GB or 73-GB disks
DVD-ROM One ATAPI DVD-ROM
Tape 4mm DDS-4 DAT SCSI Tape or 4mm DAT 72 SCSI Tape
Environment
AC input 100-240 V (+/- 10%) 47-63Hz
Heat output 2150 BTU/hr (maximum)
Input power 460 W
Temperature Operating: 5°C to 40°C (41°F to 104°F)
Nonoperating: -40°C to 65°C (-40°F to 149°F)
Humidity Operating: 10% to 90% relative humidity, noncondensing, 27°C max wet bulb
Nonoperating: up to 93% relative humidity, noncondensing, 38°C max wet bulb
Altitude Operating: Up to 3000 m, maximum operating temperature is derated by 1° C per 500 m above 500 m
Nonoperating: Up to 12000 m
Acoustic noise Less than 6.3 B sound power in ambient temperature of up to 27°C
Number of cords 2
Regulations
Meets or exceeds the following requirements:
Safety IEC60950:1999, UL 60950 3rd Edition, CAN/CSA 22.2, NO 60950-00, EN60950:2000, CE Mark (93/68/EEC
RFI/EMI FCC, Part 15 47 CFR, EN55022, CISPR 22
Immunity EN55024
Certifications Safety cULus Mark, TUV GS Mark, CE Mark
EMC FCC authorized Class A, VCCI, BSMI, C-TICK, MIC, CCC, GOST
Dimensions and Weights
Height 485.6mm (19.11in)
Width 251mm (9.88in)
Depth 613mm (24.15in)
Weight 21.5kg (47.3 lb.), minimum configuration
31kg (68.2lb.), maximum configuration

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback