Racking |
Standard telco racks: 19-in., 23-in, 24-in, and 600-mm
|
Processor |
Number |
One |
Architecture |
Sun Fire V120: UltraSPARC[tm] IIi superscalar processor: 64-bit
single processor, 550- or 650- MHz
Netra 120: UltraSPARC" IIi superscalar processor: 64-bit single
processor, 650- MHz
|
Cache memory |
16-KB data and 16-KB instruction on chip
Secondary: 512-KB internal
|
Main
Memory |
Capacities |
Four 256-MB, 512-MB, or 1-GB PC133 DIMMs
4-GB memory max per system
|
Standard
Interfaces |
Ethernet |
Two ethernet/fast ethernet (10BASE-T/100BASE-T) shielded twisted-pair
(STP) connector (RJ-45) |
PCI |
Single full length PCI slot compliant with PCI specification version
2.1; slot operates at 33-MHz, 32 bits
|
SCSI |
One 40-MB/sec, 68-pin,
UltraSCSI (SCSI-3) synchronous port |
Serial |
Two RS-232C/RS-423 serial ports (RJ45);
port A is used for LOM |
System Configuration Reader and Card |
Front-accessible for transfer of system configuration information, including
hostid
|
USB |
Two OHCI-compliant Universal Serial Bus (USB)
Type A ports |
Internal
Mass Storage |
Disks |
Up to two 3.5-in. × 1-in.disks (18GB, 36GB, or 73GB SCSI), front accessible, support
for hot plug |
CD-ROM/DVD-ROM |
Optional 644-MB SuperSlim CD-ROM, 24X speed
Optional slimline,8X speed for DVD-ROM and 40X speed for CD-ROM
|
Environment |
AC input (Sun Fire V120) |
90 - 264 VAC, 47 - 63 Hz, 2 A(max) |
DC input (Netra 120) |
-40 to -75 VDC, 4 A(max) |
Input power |
Sun Fire V120: 98 W (nominal)
Netra 120: 58 W (nominal) |
Heat output |
Sun Fire V120: Maximum 550 BTU/hr, Nominal 335 BTU/hr
Netra 120: Nominal 198 BTU/hr |
Temperature |
Operating: 5° C to 40° C (41° F to 104° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F) |
Humidity |
Operating: 5% to 85% relative humidity, noncondensing
Nonoperating: 10% to 95% relative humidity, noncondensing |
Altitude |
Operating: -300 m to 3000 m (-1000 to 10,000 ft.)
Nonoperating: -300 m to 12,000 m (-1000 to 40,000 ft.) |
Acoustic noise |
Operating: < 65 dBA |
Number of cords |
1 |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL 1950/CSA C22.2 No.950, EN 60950 (73/23/EEC), IEC 950,CCIB for PSU,
GOSTMark, GR-1089-CORE |
Emissions |
CFR Title 47 FCC Part 15, EN 55022 (89/336/EEC), GR-1089-CORE |
Immunity |
EN55024 (89/336/EEC), EN50082-1, GR-1089-CORE
|
Certification |
Safety: cULus Mark, TUV GS Mark, CE Mark
EMC: CE Mark (93/68/EEC), FCC authorized Class A, VCCI, BSMI,CTICK |
Seismic |
GR-63-CORE requirements for earthquake risk zone 4
ETSI ETS 300-19-2-3, A1 operating requirements |
Dimensions
and Weights |
Height |
4.4 cm (1.73 in.) (1 RU) |
Width |
43.7 cm (17.21 in.) |
Depth |
47.8 (18.8 in.) |
Weight |
10 kg (22 lb.) |