Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun SPARC[tm] Enterprise T5220 Server: Hardware Specifications

Processor
Number One UltraSPARC T2 multicore processor
Architecture SPARC V9 architecture, ECC protected
CPUs 1.2GHz 4-Core
1.2GHz 6-Core
1.2GHz 8-Core
1.4GHz 8-Core
1.6GHz 8-Core
Cache memory 4MB Level 2
Main Memory
Capacities Total DIMM slots: 16
DIMM type: FBDIMM
DIMM size: 1GB, 2GB, 4GB or 8GB
Maximum capacity: 128GB (16 × 8GB)
Standard Integrated Interfaces
Network 4 × 10/100/1000 Mbps ports
Network Management One dedicated 10/100Base-T RJ-45 port Ethernet port
Serial Management One dedicated RJ-45 port
Serial One DB-9 connector
SAS One LSI Logic SAS1068E SAS/SATA Controller chip interfacing to a four lane PCI-Express port
USB Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
PCI Expansion Slots
  • 6 low-profile PCI-Express slots.
  • Slots 0 and 1 support PCI-Express or proprietary 10Gbit Ethernet (XAUI) cards.
Slot #
Physical
Electrical
Location
0
x8
x4
Bottom
1
x8
x4
Bottom
2
x16
x8
Bottom
3
x8
x4
Top
4
x8
x4
Top
5
x8
x8
Top
Internal Mass Storage
Disks
  • All PTO standard configurations ship with 8 disk backplanes and cannot be changed later.
  • ATO configurations provide an 8 disk or 16 disk backplane option as a selectable item.
  • The maximum disk capacity depends on which backplane is selected, and cannot be changed later.
    • Up to 16 73GB (10K or 15K RPM), 146GB 10K RPM, and 300GB, 10K RPM SAS 2.5 inch form factor disk drives
Solid State Drives
  • Up to 8 32GB solid state drives
DVD-ROM 1 slimline DVD-Writer/CD-Writer
Power Supplies
2 × 750 Watt, hot-swappable, N+1 redundant power supply units (PSU)
Environment
Input Voltage 100 - 240 VAC, 50-60Hz
Input Current <9A RMS @ 100 VAC
3A @ 200-240 VAC (max)
Idle/Peak Power Minimum Configuration: 252 / 387 W
Maximum Configuration: 494 / 795 W
Power Consumption 795 W max
Heat Output 3121 BTU/hr (max)
Temperature

Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)

Note: Above 900m (3000 ft), decrease maximum temperature as altitude increase, 1° C/300m (1.6° F/1000ft)

Humidity Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) wet bulb
Nonoperating: 93% relative humidity noncondensing, 35° C (95° F) wet bulb
Altitude Operating: up to 3000m (10000 ft.)
Nonoperating: up to 12000m (40000 ft.)
Vibration Operating: 0.15G (z-axis), 0.10G (x,y axes) 5-500Hz sine
Nonoperating: 0.5G (z-axis), 0.25G (x,y axes) S5-500Hz sine
Shock Operating: 3G, 11ms half-sine
Nonoperating: 1-inch roll-off front-to-back, 20mm step up threshold testing of castors at 0.75m/s
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:Y
Safety UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1,2 CFR21 part 1040, CNS14336, GB4943
Ergonomics EK1-ITB-2000
RFI/EMI EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ3548 Class A CNS 13438 Class A, KSC 5858 Class A, GB9254 Class A, EN61000-3-2, GB17625.1, EN61000-3-3
Immunity EN55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
Telecommunications EN 300 386
Dimensions and Weight
Height 87.4 mm (3.49 in.)
Width 425.5 mm (16.75 in.)
Depth 714.4 mm (28.1 in.)
Weight 23.58 kg (52 lb.)
Clearance and Service Access
Front 910 mm (36 in.)
Rear 910 mm (36 in.)
Rack Mounting
Racks are as follows:
  • Sun Rack 900-36N
  • Sun Rack 900-38
  • Sun Rack 1000-38
  • Sun Rack 1000-42
  • Sun Fire Cabinet
  • StorEdge 72" Expansion Cabinet
  • 19" racks that meet EIA-310-D, including M6, 10-32, and square holes

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.