Sun StorEdge[tm] S1 Array: Hardware Specifications
 
  | 
 | 
   
    | Disks | 
   
  
   
    | 18GB | 
    
     
       - Fujitsu MAN3184MC, 18.2GB - 10000 RPM, Ultra-3 SCSI
 
       - Seagate ST318305LC, 18.2GB - 10000 RPM, Ultra-3 SCSI
 
       | 
   
  
   
    | 36GB | 
    
     
      - Seagate ST336605LC, 36.4GB - 10000 RPM, Ultra-3 SCSI
 
      - Fujitsu MAN3367MC, 36.4GB - 10000 RPM, Ultra-3 SCSI
 
      - Seagate ST336607LC, 36.4GB - 10000 RPM, Ultra-320
 
      - Fujitsu MAP3367NC, 36.4GB - 10000 RPM, Ultra-320
 
      - Hitachi DK32EJ-36NC, 36.4GB - 10000 RPM, Ultra-320
 
       | 
   
  
   
    | 73GB | 
    
     
       - Seagate ST373307LC, 73.4GB - 10000 RPM, Ultra-320
 
       - Hitachi DK32EJ-72NC, 73.4GB - 10000 RPM, Ultra-320
 
       - Fujitsu MAP3735NC, 73.4GB - 10000 RPM, Ultra-320
 
       | 
   
  
   
    | 146GB | 
    
     
       - Fujitsu MAP3147NC, 146GB - 10000 RPM, Ultra-320
 
       - Hitachi DK32EJ-14NC, 146GB - 10000 RPM, Ultra-320
 
       | 
   
  
   
    | Racking | 
   
   
    |  
       Supports 19-in., 23-in., 24-in., and 600-mm rack configurations, with 
        fixed-rail options 
     | 
   
   
    | Standard 
      Interfaces  | 
   
   
    | LVD/SE SCSI | 
     
       Two ports, 160/40 MB/s 
       Standard ANSI (X3.131-1994, X3.277-1996, SPI-3X3.252) 
       Maximum cable length 12 meters for LVD and 4 meters for SE SCSI 
       Direct connect to host on-board SCSI port with no host adapter 
      | 
   
   
    | Environment | 
   
   
    | AC input voltage | 
    100-240 VAC, 47-63 Hz | 
   
   
    | DC input voltage | 
    -48 TO -60 VDC | 
   
   
    | Input power | 
    150 W | 
   
  
    | Input current | 
    Less than 2A at 100VAC (150W) 
      Less than 4A at -40 VDC (150W)  | 
   
   
    | Heat output | 
    512 BTU/hr | 
   
   
    | Temperature 1 | 
    Operating: 5° C to 40° C (41° F to 104° F) 
      Operating(short term): -5° C to 55° C (23° F to 131° 
      F) 
      Nonoperating: -25° C to 65° C (-13° F to 149° F) | 
   
   
    | Humidity 1 | 
    Operating: 5% to 85% relative humidity, non-condensing 
      Operating(short term): 5% to 95% relative humidity, non-condensing 
      Nonoperating: 5% to 95% relative humidity, non-condensing | 
   
   
    | Altitude | 
    Operating: 0 m to 3000 m (0 ft. to 10,000 ft.) 
      Nonoperating: 0 m to 12,000 m (0 ft. to 40,000 ft.) | 
   
   
    | Acoustic noise | 
    Operating: 6.0 Bels 
      Idling: 6.0 Bels | 
   
   
    | Seismic | 
    Meets GR-63-CORE requirements for earthquake risk zone 4 | 
   
   
    | Number of cords | 
    1 | 
   
   
    | 1 - short term is defined as operating 96 consecurtive 
      hours | 
   
   
    Regulations 
      Meets or exceeds the following 
      requirements: | 
   
   
    | Safety | 
    UL/CSA-60950, EN60950, IEC950 CB Scheme with all country deviations | 
   
   
    | RFI/EMI | 
     EN55022/CISPR22 Class B, FCC CFR47 Part 15 Class B, EN61000-3-2, EN61000-3-3, 
      EN 300 386 V1.2.1 (2000-03) - Telecom Center Only | 
   
   
    | Immunity | 
    EN55024, EN 300 386 V1.2.1 (2000-03) - Telecom Center Only | 
   
   
    | Telcordia NEBS | 
    GR-63-CORE, GR-1089-CORE, SR-3580 Level-3 | 
   
   
    | Regulatory Markings | 
     CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, EK, UL/cUL, TUV-GS | 
   
   
    | Telcordia | 
    NEBS Level-3 | 
   
   
    | Dimensions 
      and Weights | 
   
   
    | Height | 
    44 mm (1.73 in.) | 
   
   
    | Width  | 
    436 mm (17.16 in.) | 
   
   
    | Depth  | 
    450 mm (17.71 in.) | 
   
   
    | Weight | 
    5.9 kg (13 lb.) without drives 
      8.8 kg (19.4 lb.) with drives | 
   
 
 
 | 
 | 
 
 
 |