Processor |
Number |
From one to four processor modules |
Architecture |
450-MHz UltraSPARC[tm]-II module |
Cache memory |
16-KB I-cache, 16-KB D-cache per processor
4-MB external cache per processor
|
Datapath |
UPA operates at 112.5-MHz with 450-MHz processor
|
Main
Memory |
Capacities |
16 DIMM module slots; four banks of four slots
Accepts 64- or 256-MB DIMMs
256-MB to 4 GB total memory capacity
|
Memory type |
144-pin 5V 60-ns memory modules |
Datapath |
576 bits wide; 512 bits data, 64 bits ECC
Up to 1.78-GB/sec throughput
|
Standard
Interfaces |
Ethernet |
One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard
connector (RJ-45), self-sensing |
Keyboard and mouse |
One standard keyboard/mouse port (mini
DIN-8) |
Parallel |
One Centronics compatible parallel port (DB25);
ECP mode capable |
PCI |
Four full-size slots compliant with PCI specification version 2.1:
- One slot operating at 33- or 66-MHz, 32- or 64-bit data bus width,
3.3 volt
- Two slots operating at 33 MHz, 32- or 64-bit data bus width, 5 volt
- One slot operating at 33 MHz, 32-bit data bus width, 5 volt
|
SCSI |
One 40MB/sec, 68-pin
,Ultra SCSI (SCSI-3), 2 channels (synchronous) |
Serial |
Two RS-232C/RS423 serial ports (DB25) |
Internal
Mass Storage |
Disks |
Up to two 9.1-, 18.2-, or 36.4-GB disk |
CD-ROM/DVD-ROM |
SunCD 32x 644-MB SCSI CD-ROM (standard; last order November 2000)
10X DVD-ROM (standard)
|
Tape |
Optional 12 to 24-GB DDS2 4-mm or 14-GB 8-mm |
Power
Supplies |
Type |
One or two N+1 redundant, hot swap universal input (one supply standard),
individual power cords |
Output |
380 W |
Power Bus |
Common, load-sharing |
Environment |
AC Input |
100 - 240 VAC, 47 - 63 Hz, 6.3 A(max) |
Input Power |
610 W |
Heat Output |
2080 BTU/hr |
Temperature1 |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -20° C to 60°° C (-4° F to 140°
F) |
Humidity |
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing |
Altitude |
Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.) |
Vibration |
Operating: 0.2G peak, 5 - 500 Hz (swept sine)
0.0002 G2/Hz, 5 - 500 Hz (random)
vertical axis only (castered configuration), vertical and horizontal axes
(foot glide configuration)
Nonoperating: 1 G peak, 5 - 500 Hz (swept sine)
0.002 G2/Hz, 5 - 500 Hz (random)
3 perpendicular axes |
Shock |
Operating: 4G peak, 11 milliseconds half-sine pulse
Nonoperating: 15G peak, 11 milliseconds half-sine pulse |
Number of Cords |
1 per power supply; 2 (max) |
1 The front and
rear doors of the cabinet must be 63% open for adequate air flow. |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL 1950, UL Canada C22.2 No. 950, TUV EN60950, UL CB Scheme to IEC 950
with full deviations |
RFI/EMI |
FCC Class A, DOC Class B, VCCI Class B, EN55022 Class B |
Immunity |
EN50082-1 |
X-ray |
DHHS 21 Subchapter J; PTB German X-ray Decree |
Dimensions
and Weights |
Height |
17.8 cm (7.0 in.)
43.8 cm (17.25 in.) shipping |
Width |
43.8 cm (17.25 in.)
60.02 cm (23.63 in.) shipping |
Depth |
69.2 cm (27.25 in.)
93.98 cm (37.0 in.) shipping |
Weight |
32.0 kg (71 lb.)
38.6 kg (85 lb.) shipping |
Power cord |
1.99 m (6.56 ft.) |
Clearance
and Service Access |
Front1 |
91.4 cm (36 in.) |
Rear1 |
91.4 cm (36 in.) |
Right1 |
91.4 cm (36 in.) |
Left1 |
91.4 cm (36 in.) |
Top1 |
91.4 cm (36 in.) |
Airflow |
|
1These
specifications refer to a sytem that is fully extended from the rack for
service. When in normal operation, there are no side clearance requirements
for the server as the air flow is from the front to rear. However, make
sure that any front or back cabinet doors are 63% open to allow adequate
airflow. This can be accomplished by removing the doors, or ensuring that
the doors have a perforated pattern that provides a 63% open area.
|
Rack
Mounting |
Fits into a standard commercial 19-inch wide, 36-inch deep
rack |