Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



Sun Fire V490/V890

2100MHz CPU/Memory Board

501-7596 501-7713
0MB FRU
FAB 270-6636
UltraSPARC IV+
Panther
October 2006 Pre-Production
L
0MB FRU
FAB 270-6636
UltraSPARC IV+
Panther
June 2007
L

CPU to Memory Association

SOCKET CPU CPU MEMORY GROUP
J2900
J2901
J3001
J3000
0 1 4 5
0 1 4 5
0 1 4 5
0 1 4 5
16 17 20 21
16 17 20 21
16 17 20 21
16 17 20 21
A0
A0
A0
A0
1st Group
1st Group
1st Group
1st Group
J7900
J7901
J8001
J8000
2 3 6 7
2 3 6 7
2 3 6 7
2 3 6 7
18 19 22 23
18 19 22 23
18 19 22 23
18 19 22 23
B0
B0
B0
B0
2nd Group
2nd Group
2nd Group
2nd Group
J3100
J3101
J3201
J3200
0 1 4 5
0 1 4 5
0 1 4 5
0 1 4 5
16 17 20 21
16 17 20 21
16 17 20 21
16 17 20 21
A1
A1
A1
A1
3rd Group
3rd Group
3rd Group
3rd Group
J8100
J8101
J8201
J8200
2 3 6 7
2 3 6 7
2 3 6 7
2 3 6 7
18 19 22 23
18 19 22 23
18 19 22 23
18 19 22 23
B1
B1
B1
B1
4th Group
4th Group
4th Group
4th Group

Sun Fire V490 Codename: Sebring
Sun Fire V890 Codename: Silverstone

Notes

  1. The minimum V490 and V890 OS is Solaris 9 9/05 or Solaris 10 3/05 HW1.
  2. Sun Fire V490 and V890 OBP >=4.22 Version 24 is required.
  3. Sun Fire V490-BASE-2100-Z chassis is required. Differences include the Centerplane, PCI I/O Board, Power Supply, Power Distribution Board, CPU Fan, and PCI Fan.
  4. Sun Fire V890-BASE-2100-Z chassis is required. Differences include the CPU Module Mounting Brackets, I/O Board, Power Supply, and Power Distribution Board.
  5. V490 and V890 upgrades are not available. Whole unit replacement is required.
  6. V490 and V890 2.1GHz Base Systems are only compatible with 2.1GHz.

Configuration Notes

  1. Mixing UltraSPARC IV and IV+ CPU/Memory boards is supported.
  2. Mixing UltraSPARC III and IV+ CPU/Memory boards is not supported.
  3. Mixing 2100MHz with any other speed CPU/Memory board is not supported.
  4. Refer to Configuration Guide 819-1813 for supported mixed speed configurations.
  5. The 2100MHz UltraSPARC IV+ is not supported in the Sun Fire V480 or V880.

Memory Notes

  1. Four DIMMs of the same size form a group.
  2. The minimum memory configuration is sixteen DIMMS.
  3. Memory errors include CPU number, J number, and Slot location.
  4. DIMM groups associated with a failed CPU are unavailable for use.
  5. Interleaving is limited to memory on the same CPU/Memory Board.
  6. Two-way interleaving occurs in any group when the DIMM size does not match the size used in any other group.
  7. Four-way interleaving occurs between any two groups when the DIMM sizes are the same.
  8. Eight-way interleaving occurs when the DIMMs in all four groups are the same size.

References

  1. Installation Notes for UltraSPARC IV+ on V490 Server, 819-1536.
  2. Installation Notes for UltraSPARC IV+ on V890 Server, 819-3748.
  3. Sun Fire V490 Server Product Notes, 819-4193.
  4. Sun Fire V490 Server Administration Guide, 817-3951.
  5. Sun Fire V490 Parts Installation and Removal Guide, 817-3952.
  6. Sun Fire V890 Server Product Notes, 817-3996.
  7. Sun Fire V890 Server Service Manual, 817-3957.
  8. Sun Fire V490/V890 CPU/Memory Module Configuration Guide, 819-1813.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback