Sun Fire V120 / Netra 120
375-3064 |
375-3065 |
0MB FRU 550MHz US IIi Sun Fire V120 February 2002 |
0MB FRU 650MHz US IIi Netra 120 Sun Fire V120 February 2002 |
375-3198 |
375-3199 |
0MB FRU 550MHz US IIi Sun Fire V120 November 2003 |
0MB FRU 650MHz US IIi Netra 120 Sun Fire V120 November 2003 |
Jumper Settings
JUMPER |
PINS |
SETTING |
DESCRIPTION |
JP8 |
1-2 3-4 |
In In |
Netra 120 setting
Sun Fire V120 setting |
JP9 |
1-2 2-3 |
In In |
Select Flash PROM (default)
Select ROMBO |
JP13 |
1-2 1-2 |
Out In |
Normal LOMlite2 operation (default)
Reset LOMlite2 |
JP14 |
1-2 1-2 |
Out In |
Normal LOMlite2 operation (default)
Bypass LOMlite2 |
JP15 |
1-2 1-2 |
Out In |
Normal LOMlite2 flash (default)
LOMlite2 flash recovery |
JP16 |
1-2 1-2 |
Out In |
OBP write protected
OBP write enabled (default) |
JP17 |
1-2 |
Out |
CD-ROM set as Master ATA device |
JP7 Speed Select Jumper Settings
1-2 |
3-4 |
5-6 |
DESCRIPTION |
PART NUMBER
(Codename = Phantom)
|
Out |
Out |
In |
550MHz UltraSPARC IIi |
100-7192 |
Out |
In |
Out |
650MHz UltraSPARC IIi |
527-1023 |
Sun Fire V120 Codename: Flapjack2+ |
Notes
- The minimum operating system is Solaris 8 10/01.
- The hostid, MAC address, and OBP environment settings are stored
on System Configuration Smart Card 370-4285.
- 375-3064, 375-3065, 375-3198, and 375-3199 are based on the
Netra T1 System Board with faster CPU, updated OBP and LOM firmware,
and JP8 installed.
- There is no Netra 120 or Sun Fire V120 UltraSPARC IIi FRU.
Memory Notes
- The minimum memory requirement is one DIMM in Slot 0.
- The memory installation sequence is Slot 0, 1, 2, and 3.
- Each DIMM slot addresses 1GB with >=550MHz UltraSPARC IIi.
- When equal size DIMMs are installed, the lowest slot number is
mapped to the lowest address range.
- When mixed size DIMMs are installed, the slot number with the
largest size DIMM is mapped to the lowest address range.
UltraSPARC IIi Notes
- The 650MHz UltraSPARC IIi is similar to the 270-440MHz UltraSPARC IIi.
Differences include integrated L2 Cache and SDRAM Memory Control.
- The 650MHz UltraSPARC IIi is based on the 500MHz UltraSPARC IIe.
- The 650MHz UltraSPARC IIi OBP and OS name is UltraSPARC IIe.
References
-
Sun Fire V120 and Netra 120 Server User's Guide, 816-2090.
-
Sun Fire V120 and Netra 120 Server Product Notes, 816-2093.
|