Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback



SCSI RAID Controller (SRC/P)

Servers: Enterprise 250, 450, 220R, 420R
Sun Fire 280R
Telco: Netra 20

Options 6542 / 6602

375-0078
DPT SmartRAID Millennium PM3755U2B
w Battery Backup Module BB4050
w SCSI Expansion Module SX4055U2-2
w 64MB ECC EDO DIMM DM4050-64
3.3/5V 64Bit 33MHz
SRC/P 375-0078
SmartRAID Millennium
DPT PM3755U2B
No Sun part number
 
Battery Backup Module FRU
DPT BB4550
375-0082

64MB DIMM
DPT DM4050-64
No Sun part number

SCSI Expansion Module
DPT SX4055U2-2
No Sun part number

Notes

  1. The minimum operating system is Solaris 2.6 Hardware: 3/98.
  2. SRC/P on Solaris 9 requires Patch 115548-01.
  3. The E250 and E450 require OBP >=3.12.
  4. The SRC/P requires a 64-Bit PCI slot.
  5. Internal Option 6602 is only available for the Enterprise 450 (A25).
  6. The maximum high-speed disk cache memory is 256MB.

Cable Notes

  1. The Enterprise 450 requires internal 8-Disk Backplane Cable 530-2744.
  2. The 68-pin VHDCI connector on Cables 530-2452-01 and 530-2453-01 is centered in the housing.
  3. The 68-pin VHDCI connector on Cables 530-2452-02 and 530-2453-02 is offset in the housing.
  4. Cables with centered VHDCI connectors are not usable at the same time on the A and B ports, due to the thickness of the connector shell. The shell thickness was reduced on cables 530-2452-02 and 530-2453-02.
  5. Cable 530-2453-02 was released in May 1999.
  6. Cable 530-2452-02 was released in May 2001.

References

  1. SRC/P Installation Guide, 805-7752.
  2. SRC/P User's Guide, 805-6768.
  3. E450 Internal RAID Storage Option Installation Guide, 805-6765.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback