6-Slot FC-AL Backplane
Servers: |
Sun Fire V880, V890 |
Option 6751
Notes
- Jumpers J0803, J0804, and J01003 are on the solder side.
- Loop-B Board 501-4877, Backplane 501-4878, and cable 530-2681 were replaced
by Backplane 501-5993 with integrated FC-AL Loop-B.
- Cables 530-2745 and 530-2863 include 8-Pin connectors.
- Connect 530-2863 P1 to J0801 on the Lower 6-Slot Backplane.
- Connect 530-2863 P2 to J0801 on the Upper 6-Slot Backplane.
- Do Not connect Power Distribution Board cable 530-2745 to J0801.
- Cable 530-2840 comes from the factory connected to P18 on the I/O board for
base backplane operation. It is tie-wrapped to the rear wall, to the left
of the expansion backplane. The secondary I/O fan may have to be removed
to reach it.
- NOTE: When updating the disk backplane firmware using patch
117814,
the superuser prompt will return after issuing the luxadm command in step 2
of the patch instructions. You must wait at least 15 minutes after the
superuser prompt returns before continuing or performing any other
operations. This minimum wait time is required for the flash update process
to propagate the firmware code to all SSC100 processors in the system.
Reference
-
Sun Fire V880 Server Service Manual, 806-6597.
6-Slot FC-AL Backplane
(Base or Expansion)
Servers: |
Sun Fire V880, V890 |
Options 6751 / 6756 / 6858 / 7858
501-5993 |
501-6665 |
501-6759 |
501-7235 |
FAB 270-5993-02 March 2001 |
FAB 270-5993-03 March 2003 |
FAB 270-5993-04 March 2004 |
FAB 270-5993-04 March 2006 L |
Notes
- Jumpers J0803, J0804, and J01003 are on the solder side.
- Cables 530-2745 and 530-2863 include 8-Pin connectors.
- Connect 530-2863 P1 to J0801 on the Lower 6-Slot Backplane.
- Connect 530-2863 P2 to J0801 on the Upper 6-Slot Backplane.
- Do Not connect P38 or P39 of I/O to PDB cable 530-2745 to J0801.
- Cable 530-2840 comes from the factory connected to P18 on the I/O board for
base backplane operation. It is tie-wrapped to the rear wall, to the left
of the expansion backplane. The secondary I/O fan may have to be removed
to reach it.
- NOTE: When updating the disk backplane firmware using patch
117814,
the superuser prompt will return after issuing the luxadm command
in step 2 of the patch instructions. You must wait at least 15 minutes
after the superuser prompt returns before continuing or performing any
other operations. This minimum wait time is required for the flash update
process to propagate the firmware code to all SSC100 processors in the
system.
Reference
-
Sun Fire V880 Server Service Manual, 806-6597.
|